Loading…

Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI

Background T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall. Pur...

Full description

Saved in:
Bibliographic Details
Published in:Acta radiologica (1987) 2024-10, Vol.65 (10), p.1196-1204
Main Authors: Won, So Yeon, Lee, Kijeong, Shin, Ilah, Choi, Hyun Seok, Choi, Jai Ho, Kim, Bum-Soo, Shin, Yong Sam
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall. Purpose To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis. Material and Methods This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%–99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated. Results The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement. Conclusion T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.
ISSN:0284-1851
1600-0455
1600-0455
DOI:10.1177/02841851241268467