Comparing flow and pulmonary artery growth post-patent ductus arteriosus stenting in patients with ductal-dependent pulmonary flow using 4D magnetic resonance imaging
The 4D magnetic resonance imaging (4D-flow MRI) provides a qualitative and quantitative assessment of cardiovascular structures and processes. 4D-flow MRI was used to study pulmonary flow in post-patent ductus arteriosus (PDA) stent insertion in duct-dependent pulmonary flow neonates at baseline (PD...
Saved in:
Published in: | European heart journal. Imaging methods and practice 2024-01, Vol.2 (1), p.qyae044 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The 4D magnetic resonance imaging (4D-flow MRI) provides a qualitative and quantitative assessment of cardiovascular structures and processes. 4D-flow MRI was used to study pulmonary flow in post-patent ductus arteriosus (PDA) stent insertion in duct-dependent pulmonary flow neonates at baseline (PDA stent insertion) and after 6 months, and also, to evaluate the effect of flow dynamics on the growth of pulmonary arteries (PAs).AimsThe 4D magnetic resonance imaging (4D-flow MRI) provides a qualitative and quantitative assessment of cardiovascular structures and processes. 4D-flow MRI was used to study pulmonary flow in post-patent ductus arteriosus (PDA) stent insertion in duct-dependent pulmonary flow neonates at baseline (PDA stent insertion) and after 6 months, and also, to evaluate the effect of flow dynamics on the growth of pulmonary arteries (PAs).This prospective observational study included neonates with ductus arteriosus-dependent pulmonary circulation who underwent ductal stenting between June 2021 and November 2022. Cardiac 4D-flow MRI and magnetic resonance angiography were conducted in two phases; after the deployment of the PDA stent during the neonatal period and after 6 months from stent deployment. Eight neonates were recruited, but only five completed both scans. A total of 10 PAs were evaluated during each phase. The median left PA (LPA) and right PA (RPA) diameters and indexed flow for LPA and RPA were evaluated. The growth rate of LPA was observed to be lower than that of RPA (percentage diameter increase: 74 vs. 153%). LPA Z-score was lower than RPA. Indexed flow in both LPA and RPA showed a reduction in the 6-month scan, which was consistent with reduced stent patency.Methods and resultsThis prospective observational study included neonates with ductus arteriosus-dependent pulmonary circulation who underwent ductal stenting between June 2021 and November 2022. Cardiac 4D-flow MRI and magnetic resonance angiography were conducted in two phases; after the deployment of the PDA stent during the neonatal period and after 6 months from stent deployment. Eight neonates were recruited, but only five completed both scans. A total of 10 PAs were evaluated during each phase. The median left PA (LPA) and right PA (RPA) diameters and indexed flow for LPA and RPA were evaluated. The growth rate of LPA was observed to be lower than that of RPA (percentage diameter increase: 74 vs. 153%). LPA Z-score was lower than RPA. Indexed flow in both LPA and |
---|---|
ISSN: | 2755-9637 2755-9637 |
DOI: | 10.1093/ehjimp/qyae044 |