Loading…

Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT

Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear medicine and molecular imaging 2024-10, Vol.58 (6), p.377-378
Main Authors: Majeed, Althaf K, Yadav, Om Kumar, Taywade, Sameer, Kumar, Rajesh, Sandhu, Arjun Singh
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853
container_end_page 378
container_issue 6
container_start_page 377
container_title Nuclear medicine and molecular imaging
container_volume 58
creator Majeed, Althaf K
Yadav, Om Kumar
Taywade, Sameer
Kumar, Rajesh
Sandhu, Arjun Singh
description Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.
doi_str_mv 10.1007/s13139-024-00855-4
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3108389444</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3108389444</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</originalsourceid><addsrcrecordid>eNp9kc9u2zAMxoVhxVp0fYEdBh138SZZiiXtFmT9MyDAitbZVaAlOnXnyJ5kH7rH6BNXWbIexwsJ8scPID9CPnD2mTOmviQuuDAFK2XBmF4sCvmGnHFdmUJIXb59rZU8JRcpPbIcojRMqHfkVBjBtDT8jDzfRnRdQroeHPTdH5i6IdChpZvYhdxF-EWX7YSR3mGAntYRQhp7CNORDPQOfK5m13ce99SwjTA-PH2lS-_R05_Qz7hXnB6QboLrYTfm9rcIXYAt0npukELw9P72clUXq_o9OWmhT3hxzOdkc3VZr26K9Y_r76vlunCl0VNRKm8qA1BJr0QjhFJcN8yX3Cy4N0xXvoKm5J61WHGjpHeN4diCEQ6F0gtxTj4ddMc4_J4xTXbXJYd9Pg6HOVnBmRbaSCkzWh5QF4eUIrZ2jN0O4pPlzO7tsAc7bLbD_rXD7pc-HvXnZof-deXf8zMgDkDKo7DFaB-HOeYvp__JvgCpjZVi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3108389444</pqid></control><display><type>article</type><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><source>Springer Nature</source><creator>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</creator><creatorcontrib>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</creatorcontrib><description>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</description><identifier>ISSN: 1869-3474</identifier><identifier>EISSN: 1869-3482</identifier><identifier>DOI: 10.1007/s13139-024-00855-4</identifier><identifier>PMID: 39308491</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Cardiology ; Imaging ; Interesting Image ; Medicine ; Medicine &amp; Public Health ; Nuclear Medicine ; Oncology ; Orthopedics ; Radiology</subject><ispartof>Nuclear medicine and molecular imaging, 2024-10, Vol.58 (6), p.377-378</ispartof><rights>The Author(s), under exclusive licence to Korean Society of Nuclear Medicine 2024</rights><rights>The Author(s), under exclusive licence to Korean Society of Nuclear Medicine 2024.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39308491$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Majeed, Althaf K</creatorcontrib><creatorcontrib>Yadav, Om Kumar</creatorcontrib><creatorcontrib>Taywade, Sameer</creatorcontrib><creatorcontrib>Kumar, Rajesh</creatorcontrib><creatorcontrib>Sandhu, Arjun Singh</creatorcontrib><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><title>Nuclear medicine and molecular imaging</title><addtitle>Nucl Med Mol Imaging</addtitle><addtitle>Nucl Med Mol Imaging</addtitle><description>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</description><subject>Cardiology</subject><subject>Imaging</subject><subject>Interesting Image</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Nuclear Medicine</subject><subject>Oncology</subject><subject>Orthopedics</subject><subject>Radiology</subject><issn>1869-3474</issn><issn>1869-3482</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc9u2zAMxoVhxVp0fYEdBh138SZZiiXtFmT9MyDAitbZVaAlOnXnyJ5kH7rH6BNXWbIexwsJ8scPID9CPnD2mTOmviQuuDAFK2XBmF4sCvmGnHFdmUJIXb59rZU8JRcpPbIcojRMqHfkVBjBtDT8jDzfRnRdQroeHPTdH5i6IdChpZvYhdxF-EWX7YSR3mGAntYRQhp7CNORDPQOfK5m13ce99SwjTA-PH2lS-_R05_Qz7hXnB6QboLrYTfm9rcIXYAt0npukELw9P72clUXq_o9OWmhT3hxzOdkc3VZr26K9Y_r76vlunCl0VNRKm8qA1BJr0QjhFJcN8yX3Cy4N0xXvoKm5J61WHGjpHeN4diCEQ6F0gtxTj4ddMc4_J4xTXbXJYd9Pg6HOVnBmRbaSCkzWh5QF4eUIrZ2jN0O4pPlzO7tsAc7bLbD_rXD7pc-HvXnZof-deXf8zMgDkDKo7DFaB-HOeYvp__JvgCpjZVi</recordid><startdate>20241001</startdate><enddate>20241001</enddate><creator>Majeed, Althaf K</creator><creator>Yadav, Om Kumar</creator><creator>Taywade, Sameer</creator><creator>Kumar, Rajesh</creator><creator>Sandhu, Arjun Singh</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20241001</creationdate><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><author>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cardiology</topic><topic>Imaging</topic><topic>Interesting Image</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Nuclear Medicine</topic><topic>Oncology</topic><topic>Orthopedics</topic><topic>Radiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Majeed, Althaf K</creatorcontrib><creatorcontrib>Yadav, Om Kumar</creatorcontrib><creatorcontrib>Taywade, Sameer</creatorcontrib><creatorcontrib>Kumar, Rajesh</creatorcontrib><creatorcontrib>Sandhu, Arjun Singh</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Nuclear medicine and molecular imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Majeed, Althaf K</au><au>Yadav, Om Kumar</au><au>Taywade, Sameer</au><au>Kumar, Rajesh</au><au>Sandhu, Arjun Singh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</atitle><jtitle>Nuclear medicine and molecular imaging</jtitle><stitle>Nucl Med Mol Imaging</stitle><addtitle>Nucl Med Mol Imaging</addtitle><date>2024-10-01</date><risdate>2024</risdate><volume>58</volume><issue>6</issue><spage>377</spage><epage>378</epage><pages>377-378</pages><issn>1869-3474</issn><eissn>1869-3482</eissn><abstract>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>39308491</pmid><doi>10.1007/s13139-024-00855-4</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1869-3474
ispartof Nuclear medicine and molecular imaging, 2024-10, Vol.58 (6), p.377-378
issn 1869-3474
1869-3482
language eng
recordid cdi_proquest_miscellaneous_3108389444
source Springer Nature
subjects Cardiology
Imaging
Interesting Image
Medicine
Medicine & Public Health
Nuclear Medicine
Oncology
Orthopedics
Radiology
title Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A17%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Precise%20Localization%20of%20Urine%20Leak%20After%20Renal%20Transplantation%20on%20Radionuclide%20Renography:%20Added%20Value%20of%20the%20Unclamped%20Drainage%20Tube%20and%20SPECT-CT&rft.jtitle=Nuclear%20medicine%20and%20molecular%20imaging&rft.au=Majeed,%20Althaf%20K&rft.date=2024-10-01&rft.volume=58&rft.issue=6&rft.spage=377&rft.epage=378&rft.pages=377-378&rft.issn=1869-3474&rft.eissn=1869-3482&rft_id=info:doi/10.1007/s13139-024-00855-4&rft_dat=%3Cproquest_cross%3E3108389444%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3108389444&rft_id=info:pmid/39308491&rfr_iscdi=true