Loading…
Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT
Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a...
Saved in:
Published in: | Nuclear medicine and molecular imaging 2024-10, Vol.58 (6), p.377-378 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853 |
container_end_page | 378 |
container_issue | 6 |
container_start_page | 377 |
container_title | Nuclear medicine and molecular imaging |
container_volume | 58 |
creator | Majeed, Althaf K Yadav, Om Kumar Taywade, Sameer Kumar, Rajesh Sandhu, Arjun Singh |
description | Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak. |
doi_str_mv | 10.1007/s13139-024-00855-4 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3108389444</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3108389444</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</originalsourceid><addsrcrecordid>eNp9kc9u2zAMxoVhxVp0fYEdBh138SZZiiXtFmT9MyDAitbZVaAlOnXnyJ5kH7rH6BNXWbIexwsJ8scPID9CPnD2mTOmviQuuDAFK2XBmF4sCvmGnHFdmUJIXb59rZU8JRcpPbIcojRMqHfkVBjBtDT8jDzfRnRdQroeHPTdH5i6IdChpZvYhdxF-EWX7YSR3mGAntYRQhp7CNORDPQOfK5m13ce99SwjTA-PH2lS-_R05_Qz7hXnB6QboLrYTfm9rcIXYAt0npukELw9P72clUXq_o9OWmhT3hxzOdkc3VZr26K9Y_r76vlunCl0VNRKm8qA1BJr0QjhFJcN8yX3Cy4N0xXvoKm5J61WHGjpHeN4diCEQ6F0gtxTj4ddMc4_J4xTXbXJYd9Pg6HOVnBmRbaSCkzWh5QF4eUIrZ2jN0O4pPlzO7tsAc7bLbD_rXD7pc-HvXnZof-deXf8zMgDkDKo7DFaB-HOeYvp__JvgCpjZVi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3108389444</pqid></control><display><type>article</type><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><source>Springer Nature</source><creator>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</creator><creatorcontrib>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</creatorcontrib><description>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</description><identifier>ISSN: 1869-3474</identifier><identifier>EISSN: 1869-3482</identifier><identifier>DOI: 10.1007/s13139-024-00855-4</identifier><identifier>PMID: 39308491</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Cardiology ; Imaging ; Interesting Image ; Medicine ; Medicine & Public Health ; Nuclear Medicine ; Oncology ; Orthopedics ; Radiology</subject><ispartof>Nuclear medicine and molecular imaging, 2024-10, Vol.58 (6), p.377-378</ispartof><rights>The Author(s), under exclusive licence to Korean Society of Nuclear Medicine 2024</rights><rights>The Author(s), under exclusive licence to Korean Society of Nuclear Medicine 2024.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39308491$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Majeed, Althaf K</creatorcontrib><creatorcontrib>Yadav, Om Kumar</creatorcontrib><creatorcontrib>Taywade, Sameer</creatorcontrib><creatorcontrib>Kumar, Rajesh</creatorcontrib><creatorcontrib>Sandhu, Arjun Singh</creatorcontrib><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><title>Nuclear medicine and molecular imaging</title><addtitle>Nucl Med Mol Imaging</addtitle><addtitle>Nucl Med Mol Imaging</addtitle><description>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</description><subject>Cardiology</subject><subject>Imaging</subject><subject>Interesting Image</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Nuclear Medicine</subject><subject>Oncology</subject><subject>Orthopedics</subject><subject>Radiology</subject><issn>1869-3474</issn><issn>1869-3482</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc9u2zAMxoVhxVp0fYEdBh138SZZiiXtFmT9MyDAitbZVaAlOnXnyJ5kH7rH6BNXWbIexwsJ8scPID9CPnD2mTOmviQuuDAFK2XBmF4sCvmGnHFdmUJIXb59rZU8JRcpPbIcojRMqHfkVBjBtDT8jDzfRnRdQroeHPTdH5i6IdChpZvYhdxF-EWX7YSR3mGAntYRQhp7CNORDPQOfK5m13ce99SwjTA-PH2lS-_R05_Qz7hXnB6QboLrYTfm9rcIXYAt0npukELw9P72clUXq_o9OWmhT3hxzOdkc3VZr26K9Y_r76vlunCl0VNRKm8qA1BJr0QjhFJcN8yX3Cy4N0xXvoKm5J61WHGjpHeN4diCEQ6F0gtxTj4ddMc4_J4xTXbXJYd9Pg6HOVnBmRbaSCkzWh5QF4eUIrZ2jN0O4pPlzO7tsAc7bLbD_rXD7pc-HvXnZof-deXf8zMgDkDKo7DFaB-HOeYvp__JvgCpjZVi</recordid><startdate>20241001</startdate><enddate>20241001</enddate><creator>Majeed, Althaf K</creator><creator>Yadav, Om Kumar</creator><creator>Taywade, Sameer</creator><creator>Kumar, Rajesh</creator><creator>Sandhu, Arjun Singh</creator><general>Springer Nature Singapore</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20241001</creationdate><title>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</title><author>Majeed, Althaf K ; Yadav, Om Kumar ; Taywade, Sameer ; Kumar, Rajesh ; Sandhu, Arjun Singh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cardiology</topic><topic>Imaging</topic><topic>Interesting Image</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Nuclear Medicine</topic><topic>Oncology</topic><topic>Orthopedics</topic><topic>Radiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Majeed, Althaf K</creatorcontrib><creatorcontrib>Yadav, Om Kumar</creatorcontrib><creatorcontrib>Taywade, Sameer</creatorcontrib><creatorcontrib>Kumar, Rajesh</creatorcontrib><creatorcontrib>Sandhu, Arjun Singh</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Nuclear medicine and molecular imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Majeed, Althaf K</au><au>Yadav, Om Kumar</au><au>Taywade, Sameer</au><au>Kumar, Rajesh</au><au>Sandhu, Arjun Singh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT</atitle><jtitle>Nuclear medicine and molecular imaging</jtitle><stitle>Nucl Med Mol Imaging</stitle><addtitle>Nucl Med Mol Imaging</addtitle><date>2024-10-01</date><risdate>2024</risdate><volume>58</volume><issue>6</issue><spage>377</spage><epage>378</epage><pages>377-378</pages><issn>1869-3474</issn><eissn>1869-3482</eissn><abstract>Identifying and localizing the site of post-renal transplantation urine leaks is important for patient management and treatment planning. Renal scintigraphy is a proven modality for confirming urine leaks after complicated post-renal transplantation. Routinely, renogram studies are performed with a clamped extraperitoneal drain. This results in the spread of radioactivity in the abdominal region, which makes localization of the leak site difficult in the planar images. Here we are trying to give an insight into minimalizing the accumulated urine volume by an unclamped extraperitoneal drain in order to precisely localize the site of the leak.</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>39308491</pmid><doi>10.1007/s13139-024-00855-4</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1869-3474 |
ispartof | Nuclear medicine and molecular imaging, 2024-10, Vol.58 (6), p.377-378 |
issn | 1869-3474 1869-3482 |
language | eng |
recordid | cdi_proquest_miscellaneous_3108389444 |
source | Springer Nature |
subjects | Cardiology Imaging Interesting Image Medicine Medicine & Public Health Nuclear Medicine Oncology Orthopedics Radiology |
title | Precise Localization of Urine Leak After Renal Transplantation on Radionuclide Renography: Added Value of the Unclamped Drainage Tube and SPECT-CT |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A17%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Precise%20Localization%20of%20Urine%20Leak%20After%20Renal%20Transplantation%20on%20Radionuclide%20Renography:%20Added%20Value%20of%20the%20Unclamped%20Drainage%20Tube%20and%20SPECT-CT&rft.jtitle=Nuclear%20medicine%20and%20molecular%20imaging&rft.au=Majeed,%20Althaf%20K&rft.date=2024-10-01&rft.volume=58&rft.issue=6&rft.spage=377&rft.epage=378&rft.pages=377-378&rft.issn=1869-3474&rft.eissn=1869-3482&rft_id=info:doi/10.1007/s13139-024-00855-4&rft_dat=%3Cproquest_cross%3E3108389444%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c298t-27d969aa64d73b337718b0d21951d9086d6ab21d0fe61974dcb91efa93ce37853%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3108389444&rft_id=info:pmid/39308491&rfr_iscdi=true |