Loading…
Design and application of microfluidics in aptamer SELEX and Aptasensors
Aptamers are excellent recognition molecules obtained from systematic evolution of ligands by exponential enrichment (SELEX) that have been extensively researched for constructing aptasensors. However, in the process from SELEX to the construction of aptasensors, there are many disadvantages, such a...
Saved in:
Published in: | Biotechnology advances 2024-12, Vol.77, p.108461, Article 108461 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c249t-9f694ff02aaa8ff81dd18102fe2b71b9769808e9c003a82922a032cf1b23dac53 |
container_end_page | |
container_issue | |
container_start_page | 108461 |
container_title | Biotechnology advances |
container_volume | 77 |
creator | Zhang, Shikun Zhang, Yingming Ning, Zhiyuan Duan, Mengxia Lin, Xianfeng Duan, Nuo Wang, Zhouping Wu, Shijia |
description | Aptamers are excellent recognition molecules obtained from systematic evolution of ligands by exponential enrichment (SELEX) that have been extensively researched for constructing aptasensors. However, in the process from SELEX to the construction of aptasensors, there are many disadvantages, such as tedious and repetitive operations, interference from external factors, and low efficiency, which seriously limits their application scope and development. Introducing the microfluidic technology can realize the integration and intelligence of SELEX and aptasensing, improve the efficiency of SELEX, and enhance the detection performance and convenience of aptasensing. Hence, in this review, the characteristics of various chips based on different driving forces are described firstly. And then summarizing the design of microfluidic devices based on different SELEX methods and showing the strategies of microfluidic aptasensors based on different detection modes. Finally, discussing the difficulties and challenges encountered when microfluidic is integrated with the SELEX and the aptasensors.
•Microfluidic chips are categorized according to their different driving forces.•The SELEX chips are classified by the separation and the SELEX integrated in chip.•Microfluidic aptasensors chips are sorted according to different signals.•Difficulties and challenges and discussed, and some solutions are proposed. |
doi_str_mv | 10.1016/j.biotechadv.2024.108461 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3114151060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0734975024001551</els_id><sourcerecordid>3114151060</sourcerecordid><originalsourceid>FETCH-LOGICAL-c249t-9f694ff02aaa8ff81dd18102fe2b71b9769808e9c003a82922a032cf1b23dac53</originalsourceid><addsrcrecordid>eNqFkE1PGzEQhi1EBSntX0B77GXTGXs_7CMNgSBF6qGt1Jvltceto_3C3kTi37M0AY49jfTqeWc0D2MZwhIBq6-7ZROGiexf4w5LDryYY1lUeMYWKGuRo1TqnC2gFkWu6hIu2ceUdgBYQiku2KVQoi5qVS_Y5pZS-NNnpneZGcc2WDOFoc8Gn3XBxsG3--CCTVmYmXEyHcXsx3q7_v2vcTMnifo0xPSJffCmTfT5NK_Yr7v1z9Um336_f1jdbHPLCzXlyleq8B64MUZ6L9E5lAjcE29qbFRdKQmSlAUQRnLFuQHBrceGC2dsKa7Yl-PeMQ6Pe0qT7kKy1Lamp2GftEAssESoYEblEZ3_SCmS12MMnYlPGkG_eNQ7_e5Rv3jUR49z9fp0Zd905N6Kr-Jm4NsRoPnXQ6Cokw3UW3Ihkp20G8L_rzwDJIqIZA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3114151060</pqid></control><display><type>article</type><title>Design and application of microfluidics in aptamer SELEX and Aptasensors</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Zhang, Shikun ; Zhang, Yingming ; Ning, Zhiyuan ; Duan, Mengxia ; Lin, Xianfeng ; Duan, Nuo ; Wang, Zhouping ; Wu, Shijia</creator><creatorcontrib>Zhang, Shikun ; Zhang, Yingming ; Ning, Zhiyuan ; Duan, Mengxia ; Lin, Xianfeng ; Duan, Nuo ; Wang, Zhouping ; Wu, Shijia</creatorcontrib><description>Aptamers are excellent recognition molecules obtained from systematic evolution of ligands by exponential enrichment (SELEX) that have been extensively researched for constructing aptasensors. However, in the process from SELEX to the construction of aptasensors, there are many disadvantages, such as tedious and repetitive operations, interference from external factors, and low efficiency, which seriously limits their application scope and development. Introducing the microfluidic technology can realize the integration and intelligence of SELEX and aptasensing, improve the efficiency of SELEX, and enhance the detection performance and convenience of aptasensing. Hence, in this review, the characteristics of various chips based on different driving forces are described firstly. And then summarizing the design of microfluidic devices based on different SELEX methods and showing the strategies of microfluidic aptasensors based on different detection modes. Finally, discussing the difficulties and challenges encountered when microfluidic is integrated with the SELEX and the aptasensors.
•Microfluidic chips are categorized according to their different driving forces.•The SELEX chips are classified by the separation and the SELEX integrated in chip.•Microfluidic aptasensors chips are sorted according to different signals.•Difficulties and challenges and discussed, and some solutions are proposed.</description><identifier>ISSN: 0734-9750</identifier><identifier>ISSN: 1873-1899</identifier><identifier>EISSN: 1873-1899</identifier><identifier>DOI: 10.1016/j.biotechadv.2024.108461</identifier><identifier>PMID: 39374797</identifier><language>eng</language><publisher>England: Elsevier Inc</publisher><subject>Aptamers, Nucleotide - chemistry ; Aptasensors ; Biosensing Techniques - methods ; Chip design ; Driving forces ; Equipment Design ; Humans ; Microfluidic Analytical Techniques ; Microfluidic technology ; Microfluidics - methods ; SELEX Aptamer Technique - methods ; SELEX integration</subject><ispartof>Biotechnology advances, 2024-12, Vol.77, p.108461, Article 108461</ispartof><rights>2024 Elsevier Inc.</rights><rights>Copyright © 2024 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c249t-9f694ff02aaa8ff81dd18102fe2b71b9769808e9c003a82922a032cf1b23dac53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39374797$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Shikun</creatorcontrib><creatorcontrib>Zhang, Yingming</creatorcontrib><creatorcontrib>Ning, Zhiyuan</creatorcontrib><creatorcontrib>Duan, Mengxia</creatorcontrib><creatorcontrib>Lin, Xianfeng</creatorcontrib><creatorcontrib>Duan, Nuo</creatorcontrib><creatorcontrib>Wang, Zhouping</creatorcontrib><creatorcontrib>Wu, Shijia</creatorcontrib><title>Design and application of microfluidics in aptamer SELEX and Aptasensors</title><title>Biotechnology advances</title><addtitle>Biotechnol Adv</addtitle><description>Aptamers are excellent recognition molecules obtained from systematic evolution of ligands by exponential enrichment (SELEX) that have been extensively researched for constructing aptasensors. However, in the process from SELEX to the construction of aptasensors, there are many disadvantages, such as tedious and repetitive operations, interference from external factors, and low efficiency, which seriously limits their application scope and development. Introducing the microfluidic technology can realize the integration and intelligence of SELEX and aptasensing, improve the efficiency of SELEX, and enhance the detection performance and convenience of aptasensing. Hence, in this review, the characteristics of various chips based on different driving forces are described firstly. And then summarizing the design of microfluidic devices based on different SELEX methods and showing the strategies of microfluidic aptasensors based on different detection modes. Finally, discussing the difficulties and challenges encountered when microfluidic is integrated with the SELEX and the aptasensors.
•Microfluidic chips are categorized according to their different driving forces.•The SELEX chips are classified by the separation and the SELEX integrated in chip.•Microfluidic aptasensors chips are sorted according to different signals.•Difficulties and challenges and discussed, and some solutions are proposed.</description><subject>Aptamers, Nucleotide - chemistry</subject><subject>Aptasensors</subject><subject>Biosensing Techniques - methods</subject><subject>Chip design</subject><subject>Driving forces</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Microfluidic Analytical Techniques</subject><subject>Microfluidic technology</subject><subject>Microfluidics - methods</subject><subject>SELEX Aptamer Technique - methods</subject><subject>SELEX integration</subject><issn>0734-9750</issn><issn>1873-1899</issn><issn>1873-1899</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkE1PGzEQhi1EBSntX0B77GXTGXs_7CMNgSBF6qGt1Jvltceto_3C3kTi37M0AY49jfTqeWc0D2MZwhIBq6-7ZROGiexf4w5LDryYY1lUeMYWKGuRo1TqnC2gFkWu6hIu2ceUdgBYQiku2KVQoi5qVS_Y5pZS-NNnpneZGcc2WDOFoc8Gn3XBxsG3--CCTVmYmXEyHcXsx3q7_v2vcTMnifo0xPSJffCmTfT5NK_Yr7v1z9Um336_f1jdbHPLCzXlyleq8B64MUZ6L9E5lAjcE29qbFRdKQmSlAUQRnLFuQHBrceGC2dsKa7Yl-PeMQ6Pe0qT7kKy1Lamp2GftEAssESoYEblEZ3_SCmS12MMnYlPGkG_eNQ7_e5Rv3jUR49z9fp0Zd905N6Kr-Jm4NsRoPnXQ6Cokw3UW3Ihkp20G8L_rzwDJIqIZA</recordid><startdate>202412</startdate><enddate>202412</enddate><creator>Zhang, Shikun</creator><creator>Zhang, Yingming</creator><creator>Ning, Zhiyuan</creator><creator>Duan, Mengxia</creator><creator>Lin, Xianfeng</creator><creator>Duan, Nuo</creator><creator>Wang, Zhouping</creator><creator>Wu, Shijia</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202412</creationdate><title>Design and application of microfluidics in aptamer SELEX and Aptasensors</title><author>Zhang, Shikun ; Zhang, Yingming ; Ning, Zhiyuan ; Duan, Mengxia ; Lin, Xianfeng ; Duan, Nuo ; Wang, Zhouping ; Wu, Shijia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c249t-9f694ff02aaa8ff81dd18102fe2b71b9769808e9c003a82922a032cf1b23dac53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aptamers, Nucleotide - chemistry</topic><topic>Aptasensors</topic><topic>Biosensing Techniques - methods</topic><topic>Chip design</topic><topic>Driving forces</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Microfluidic Analytical Techniques</topic><topic>Microfluidic technology</topic><topic>Microfluidics - methods</topic><topic>SELEX Aptamer Technique - methods</topic><topic>SELEX integration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Shikun</creatorcontrib><creatorcontrib>Zhang, Yingming</creatorcontrib><creatorcontrib>Ning, Zhiyuan</creatorcontrib><creatorcontrib>Duan, Mengxia</creatorcontrib><creatorcontrib>Lin, Xianfeng</creatorcontrib><creatorcontrib>Duan, Nuo</creatorcontrib><creatorcontrib>Wang, Zhouping</creatorcontrib><creatorcontrib>Wu, Shijia</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biotechnology advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Shikun</au><au>Zhang, Yingming</au><au>Ning, Zhiyuan</au><au>Duan, Mengxia</au><au>Lin, Xianfeng</au><au>Duan, Nuo</au><au>Wang, Zhouping</au><au>Wu, Shijia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and application of microfluidics in aptamer SELEX and Aptasensors</atitle><jtitle>Biotechnology advances</jtitle><addtitle>Biotechnol Adv</addtitle><date>2024-12</date><risdate>2024</risdate><volume>77</volume><spage>108461</spage><pages>108461-</pages><artnum>108461</artnum><issn>0734-9750</issn><issn>1873-1899</issn><eissn>1873-1899</eissn><abstract>Aptamers are excellent recognition molecules obtained from systematic evolution of ligands by exponential enrichment (SELEX) that have been extensively researched for constructing aptasensors. However, in the process from SELEX to the construction of aptasensors, there are many disadvantages, such as tedious and repetitive operations, interference from external factors, and low efficiency, which seriously limits their application scope and development. Introducing the microfluidic technology can realize the integration and intelligence of SELEX and aptasensing, improve the efficiency of SELEX, and enhance the detection performance and convenience of aptasensing. Hence, in this review, the characteristics of various chips based on different driving forces are described firstly. And then summarizing the design of microfluidic devices based on different SELEX methods and showing the strategies of microfluidic aptasensors based on different detection modes. Finally, discussing the difficulties and challenges encountered when microfluidic is integrated with the SELEX and the aptasensors.
•Microfluidic chips are categorized according to their different driving forces.•The SELEX chips are classified by the separation and the SELEX integrated in chip.•Microfluidic aptasensors chips are sorted according to different signals.•Difficulties and challenges and discussed, and some solutions are proposed.</abstract><cop>England</cop><pub>Elsevier Inc</pub><pmid>39374797</pmid><doi>10.1016/j.biotechadv.2024.108461</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0734-9750 |
ispartof | Biotechnology advances, 2024-12, Vol.77, p.108461, Article 108461 |
issn | 0734-9750 1873-1899 1873-1899 |
language | eng |
recordid | cdi_proquest_miscellaneous_3114151060 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Aptamers, Nucleotide - chemistry Aptasensors Biosensing Techniques - methods Chip design Driving forces Equipment Design Humans Microfluidic Analytical Techniques Microfluidic technology Microfluidics - methods SELEX Aptamer Technique - methods SELEX integration |
title | Design and application of microfluidics in aptamer SELEX and Aptasensors |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A13%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20application%20of%20microfluidics%20in%20aptamer%20SELEX%20and%20Aptasensors&rft.jtitle=Biotechnology%20advances&rft.au=Zhang,%20Shikun&rft.date=2024-12&rft.volume=77&rft.spage=108461&rft.pages=108461-&rft.artnum=108461&rft.issn=0734-9750&rft.eissn=1873-1899&rft_id=info:doi/10.1016/j.biotechadv.2024.108461&rft_dat=%3Cproquest_cross%3E3114151060%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c249t-9f694ff02aaa8ff81dd18102fe2b71b9769808e9c003a82922a032cf1b23dac53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3114151060&rft_id=info:pmid/39374797&rfr_iscdi=true |