Accuracy of deep learning-based attenuation correction in 99mTc-GSA SPECT/CT hepatic imaging

Attenuation correction (AC) is necessary for accurate assessment of radioactive distribution in single photon emission computed tomography (SPECT). The method of computed tomography-based AC (CTAC) is widely used because of its accuracy. However, patients are exposed to radiation during CT examinati...

Full description

Saved in:
Bibliographic Details
Published in:Radiography (London, England. 1995) England. 1995), 2025-01, Vol.31 (1), p.112-117
Main Authors: Miyai, M., Fukui, R., Nakashima, M., Hasegawa, D., Goto, S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Attenuation correction (AC) is necessary for accurate assessment of radioactive distribution in single photon emission computed tomography (SPECT). The method of computed tomography-based AC (CTAC) is widely used because of its accuracy. However, patients are exposed to radiation during CT examination. The purpose of this study was to generate pseudo CT images for AC from non-AC SPECT images using deep learning and evaluate the effect of deep learning-based AC in 99mTc-labeled galactosyl human serum albumin SPECT/CT imaging. A cycle-consistent generative network (CycleGAN) was used to generate pseudo CT images. The test cohort consisted of each one patient with normal and abnormal liver function. SPECT images were reconstructed without AC (SPECTNC), with conventional CTAC (SPECTCTAC), and with deep learning-based AC (SPECTGAN). The accuracy of each AC was evaluated using the total liver count and the structural similarity index (SSIM) of SPECTCTAC and SPECTGAN. The coefficient of variation (%CV) was used to assess uniformity. The total liver counts in SPECTGAN were significantly improved over those in SPECTNC and differed from those of SPECTCTAC by approximately 7 % in both patients. The %CV in SPECTCTAC and SPECTGAN were significantly lower than those in SPECTNC. The mean SSIM in SPECTCTAC and SPECTGAN for patients with normal and abnormal liver functions were 0.985 and 0.977, respectively. The accuracy of AC with a deep learning-based method was similarly performed as the conventional CTAC. Our proposed method used only non-AC SPECT images for AC, which has great potential to reduce patient exposure by eliminating CT examination. AC of 99mTc-GSA was achieved using pseudo CT images generated with CycleGAN. Further studies on changing liver morphology and various hepatic diseases are recommended.
ISSN:1078-8174
1532-2831
1532-2831