Loading…

An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically

Stand-alone oblique lumbar interbody fusion (OLIF) cannot provide credible postoperative stability; additional fixation devices (AFDs) have been used to optimize surgical segment stability. Anterior lateral single rod (ALSR) screw fixation can be performed without intraoperative body position change...

Full description

Saved in:
Bibliographic Details
Published in:Annals of biomedical engineering 2024-12
Main Authors: Cai, Ping, Xu, Chen, Zhang, Zifan, Fang, Zhongxin, Deng, Chao, Chen, Gang, Wang, Guoyou, Li, Jingchi
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c184t-64702dc45fea46a108ff56f63784bfa4faf78e53c1d0dc5c1725b586598aa9133
container_end_page
container_issue
container_start_page
container_title Annals of biomedical engineering
container_volume
creator Cai, Ping
Xu, Chen
Zhang, Zifan
Fang, Zhongxin
Deng, Chao
Chen, Gang
Wang, Guoyou
Li, Jingchi
description Stand-alone oblique lumbar interbody fusion (OLIF) cannot provide credible postoperative stability; additional fixation devices (AFDs) have been used to optimize surgical segment stability. Anterior lateral single rod (ALSR) screw fixation can be performed without intraoperative body position changes and additional surgical incisions, but its biomechanical defect may trigger complications. Inspired by the cross screw in other fixation devices, we designed an OLIF cage integrated with a low-profile plate and cross screw (LPCS). This study was designed to investigate whether the biomechanical performance of the LPCS OLIF cage is better than that of OLIF with ALSR fixation. The pullout and bending strength of the newly designed conical screw were tested by comparing it with a clinically used cylindrical screw. Different directional fixation strengths of the LPCS OLIF cage were tested by comparing the failure moment and stiffness with the ALSR fixation model. To test the fixation stability and potential risk for screw loosening in models with LPCS OLIF, we also compared the surgical segment's range of motions (ROMs) and stress distributions on OLIF models without and with different AFD fixation under physiological loading conditions. The bending and pullout strength of the conical screw was better than that of the clinically used screw, and the failure moment and stiffness of the LPCS OLIF model were higher than those of the ALSR model, especially under the extension loading conditions. In which, the maximum failure moment of ALSR fixed OLIF model was 0.88 Nm and 0.76 Nm, while that of the LPCS OLIF model was 9.79 Nm and 7.48 Nm in models with normal and osteoporotic BMD, respectively. Compared to the ALSR fixed OLIF model, failure moment of LPCS models increased by 1012.5% and 884.21% in normal and osteoporotic models, respectively. Moreover, under most physiological loading conditions, the ROM and stress values of the LPCS OLIF model were lower than those of the ALSR model and even slightly lower than those of the OLIF model with bilateral pedicle screw fixation under limited loading conditions. Compared to OLIF with ALSR fixation, the newly developed LPCS OLIF cage demonstrates inherent biomechanical advantages in establishing immediate postoperative stability and reducing complications related to stress concentration. However, the conclusions of current research should still be validated through in vitro mechanical tests and clinical trials.
doi_str_mv 10.1007/s10439-024-03643-5
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3146531024</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3146531024</sourcerecordid><originalsourceid>FETCH-LOGICAL-c184t-64702dc45fea46a108ff56f63784bfa4faf78e53c1d0dc5c1725b586598aa9133</originalsourceid><addsrcrecordid>eNo9kM9u1DAQhy0EokvbF-CA5sjF1F7_iXMsEW1XWqmrFs6W1xl3A068xAmrvgDPXbdbOI1m5pufNB8hHzn7whmrLjJnUtSULSVlQktB1Ruy4KoStNZGvyULxmpGda3lCfmQ80_GODdCvScnotZCC8MW5O_lALfr1RU07gFhNUz4MLoJWzh00w4crNOBbsYUuoiwiWUDbmihGVPOcO9HPGRo0hxbuMN29gjTDuGuy78gBdikPKU9lrzuDxas38fOlyYNGb52qUe_c0OZxPh4Rt4FFzOev9ZT8uPq2_fmhq5vr1fN5Zp6buREtazYsvVSBXRSO85MCEoHLSojt8HJ4EJlUAnPW9Z65Xm1VFtltKqNczUX4pR8Pubux_R7xjzZvsseY3QDpjlbwaVWghelBV0eUf_87IjB7seud-Oj5cw--7dH_7bA9sW_VeXo02v-vO2x_X_yT7h4AolsgTs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3146531024</pqid></control><display><type>article</type><title>An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically</title><source>Springer Nature</source><creator>Cai, Ping ; Xu, Chen ; Zhang, Zifan ; Fang, Zhongxin ; Deng, Chao ; Chen, Gang ; Wang, Guoyou ; Li, Jingchi</creator><creatorcontrib>Cai, Ping ; Xu, Chen ; Zhang, Zifan ; Fang, Zhongxin ; Deng, Chao ; Chen, Gang ; Wang, Guoyou ; Li, Jingchi</creatorcontrib><description>Stand-alone oblique lumbar interbody fusion (OLIF) cannot provide credible postoperative stability; additional fixation devices (AFDs) have been used to optimize surgical segment stability. Anterior lateral single rod (ALSR) screw fixation can be performed without intraoperative body position changes and additional surgical incisions, but its biomechanical defect may trigger complications. Inspired by the cross screw in other fixation devices, we designed an OLIF cage integrated with a low-profile plate and cross screw (LPCS). This study was designed to investigate whether the biomechanical performance of the LPCS OLIF cage is better than that of OLIF with ALSR fixation. The pullout and bending strength of the newly designed conical screw were tested by comparing it with a clinically used cylindrical screw. Different directional fixation strengths of the LPCS OLIF cage were tested by comparing the failure moment and stiffness with the ALSR fixation model. To test the fixation stability and potential risk for screw loosening in models with LPCS OLIF, we also compared the surgical segment's range of motions (ROMs) and stress distributions on OLIF models without and with different AFD fixation under physiological loading conditions. The bending and pullout strength of the conical screw was better than that of the clinically used screw, and the failure moment and stiffness of the LPCS OLIF model were higher than those of the ALSR model, especially under the extension loading conditions. In which, the maximum failure moment of ALSR fixed OLIF model was 0.88 Nm and 0.76 Nm, while that of the LPCS OLIF model was 9.79 Nm and 7.48 Nm in models with normal and osteoporotic BMD, respectively. Compared to the ALSR fixed OLIF model, failure moment of LPCS models increased by 1012.5% and 884.21% in normal and osteoporotic models, respectively. Moreover, under most physiological loading conditions, the ROM and stress values of the LPCS OLIF model were lower than those of the ALSR model and even slightly lower than those of the OLIF model with bilateral pedicle screw fixation under limited loading conditions. Compared to OLIF with ALSR fixation, the newly developed LPCS OLIF cage demonstrates inherent biomechanical advantages in establishing immediate postoperative stability and reducing complications related to stress concentration. However, the conclusions of current research should still be validated through in vitro mechanical tests and clinical trials.</description><identifier>ISSN: 0090-6964</identifier><identifier>ISSN: 1573-9686</identifier><identifier>EISSN: 1573-9686</identifier><identifier>DOI: 10.1007/s10439-024-03643-5</identifier><identifier>PMID: 39636380</identifier><language>eng</language><publisher>United States</publisher><ispartof>Annals of biomedical engineering, 2024-12</ispartof><rights>2024. The Author(s) under exclusive licence to Biomedical Engineering Society.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c184t-64702dc45fea46a108ff56f63784bfa4faf78e53c1d0dc5c1725b586598aa9133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39636380$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cai, Ping</creatorcontrib><creatorcontrib>Xu, Chen</creatorcontrib><creatorcontrib>Zhang, Zifan</creatorcontrib><creatorcontrib>Fang, Zhongxin</creatorcontrib><creatorcontrib>Deng, Chao</creatorcontrib><creatorcontrib>Chen, Gang</creatorcontrib><creatorcontrib>Wang, Guoyou</creatorcontrib><creatorcontrib>Li, Jingchi</creatorcontrib><title>An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically</title><title>Annals of biomedical engineering</title><addtitle>Ann Biomed Eng</addtitle><description>Stand-alone oblique lumbar interbody fusion (OLIF) cannot provide credible postoperative stability; additional fixation devices (AFDs) have been used to optimize surgical segment stability. Anterior lateral single rod (ALSR) screw fixation can be performed without intraoperative body position changes and additional surgical incisions, but its biomechanical defect may trigger complications. Inspired by the cross screw in other fixation devices, we designed an OLIF cage integrated with a low-profile plate and cross screw (LPCS). This study was designed to investigate whether the biomechanical performance of the LPCS OLIF cage is better than that of OLIF with ALSR fixation. The pullout and bending strength of the newly designed conical screw were tested by comparing it with a clinically used cylindrical screw. Different directional fixation strengths of the LPCS OLIF cage were tested by comparing the failure moment and stiffness with the ALSR fixation model. To test the fixation stability and potential risk for screw loosening in models with LPCS OLIF, we also compared the surgical segment's range of motions (ROMs) and stress distributions on OLIF models without and with different AFD fixation under physiological loading conditions. The bending and pullout strength of the conical screw was better than that of the clinically used screw, and the failure moment and stiffness of the LPCS OLIF model were higher than those of the ALSR model, especially under the extension loading conditions. In which, the maximum failure moment of ALSR fixed OLIF model was 0.88 Nm and 0.76 Nm, while that of the LPCS OLIF model was 9.79 Nm and 7.48 Nm in models with normal and osteoporotic BMD, respectively. Compared to the ALSR fixed OLIF model, failure moment of LPCS models increased by 1012.5% and 884.21% in normal and osteoporotic models, respectively. Moreover, under most physiological loading conditions, the ROM and stress values of the LPCS OLIF model were lower than those of the ALSR model and even slightly lower than those of the OLIF model with bilateral pedicle screw fixation under limited loading conditions. Compared to OLIF with ALSR fixation, the newly developed LPCS OLIF cage demonstrates inherent biomechanical advantages in establishing immediate postoperative stability and reducing complications related to stress concentration. However, the conclusions of current research should still be validated through in vitro mechanical tests and clinical trials.</description><issn>0090-6964</issn><issn>1573-9686</issn><issn>1573-9686</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9kM9u1DAQhy0EokvbF-CA5sjF1F7_iXMsEW1XWqmrFs6W1xl3A068xAmrvgDPXbdbOI1m5pufNB8hHzn7whmrLjJnUtSULSVlQktB1Ruy4KoStNZGvyULxmpGda3lCfmQ80_GODdCvScnotZCC8MW5O_lALfr1RU07gFhNUz4MLoJWzh00w4crNOBbsYUuoiwiWUDbmihGVPOcO9HPGRo0hxbuMN29gjTDuGuy78gBdikPKU9lrzuDxas38fOlyYNGb52qUe_c0OZxPh4Rt4FFzOev9ZT8uPq2_fmhq5vr1fN5Zp6buREtazYsvVSBXRSO85MCEoHLSojt8HJ4EJlUAnPW9Z65Xm1VFtltKqNczUX4pR8Pubux_R7xjzZvsseY3QDpjlbwaVWghelBV0eUf_87IjB7seud-Oj5cw--7dH_7bA9sW_VeXo02v-vO2x_X_yT7h4AolsgTs</recordid><startdate>20241205</startdate><enddate>20241205</enddate><creator>Cai, Ping</creator><creator>Xu, Chen</creator><creator>Zhang, Zifan</creator><creator>Fang, Zhongxin</creator><creator>Deng, Chao</creator><creator>Chen, Gang</creator><creator>Wang, Guoyou</creator><creator>Li, Jingchi</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20241205</creationdate><title>An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically</title><author>Cai, Ping ; Xu, Chen ; Zhang, Zifan ; Fang, Zhongxin ; Deng, Chao ; Chen, Gang ; Wang, Guoyou ; Li, Jingchi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c184t-64702dc45fea46a108ff56f63784bfa4faf78e53c1d0dc5c1725b586598aa9133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cai, Ping</creatorcontrib><creatorcontrib>Xu, Chen</creatorcontrib><creatorcontrib>Zhang, Zifan</creatorcontrib><creatorcontrib>Fang, Zhongxin</creatorcontrib><creatorcontrib>Deng, Chao</creatorcontrib><creatorcontrib>Chen, Gang</creatorcontrib><creatorcontrib>Wang, Guoyou</creatorcontrib><creatorcontrib>Li, Jingchi</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cai, Ping</au><au>Xu, Chen</au><au>Zhang, Zifan</au><au>Fang, Zhongxin</au><au>Deng, Chao</au><au>Chen, Gang</au><au>Wang, Guoyou</au><au>Li, Jingchi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically</atitle><jtitle>Annals of biomedical engineering</jtitle><addtitle>Ann Biomed Eng</addtitle><date>2024-12-05</date><risdate>2024</risdate><issn>0090-6964</issn><issn>1573-9686</issn><eissn>1573-9686</eissn><abstract>Stand-alone oblique lumbar interbody fusion (OLIF) cannot provide credible postoperative stability; additional fixation devices (AFDs) have been used to optimize surgical segment stability. Anterior lateral single rod (ALSR) screw fixation can be performed without intraoperative body position changes and additional surgical incisions, but its biomechanical defect may trigger complications. Inspired by the cross screw in other fixation devices, we designed an OLIF cage integrated with a low-profile plate and cross screw (LPCS). This study was designed to investigate whether the biomechanical performance of the LPCS OLIF cage is better than that of OLIF with ALSR fixation. The pullout and bending strength of the newly designed conical screw were tested by comparing it with a clinically used cylindrical screw. Different directional fixation strengths of the LPCS OLIF cage were tested by comparing the failure moment and stiffness with the ALSR fixation model. To test the fixation stability and potential risk for screw loosening in models with LPCS OLIF, we also compared the surgical segment's range of motions (ROMs) and stress distributions on OLIF models without and with different AFD fixation under physiological loading conditions. The bending and pullout strength of the conical screw was better than that of the clinically used screw, and the failure moment and stiffness of the LPCS OLIF model were higher than those of the ALSR model, especially under the extension loading conditions. In which, the maximum failure moment of ALSR fixed OLIF model was 0.88 Nm and 0.76 Nm, while that of the LPCS OLIF model was 9.79 Nm and 7.48 Nm in models with normal and osteoporotic BMD, respectively. Compared to the ALSR fixed OLIF model, failure moment of LPCS models increased by 1012.5% and 884.21% in normal and osteoporotic models, respectively. Moreover, under most physiological loading conditions, the ROM and stress values of the LPCS OLIF model were lower than those of the ALSR model and even slightly lower than those of the OLIF model with bilateral pedicle screw fixation under limited loading conditions. Compared to OLIF with ALSR fixation, the newly developed LPCS OLIF cage demonstrates inherent biomechanical advantages in establishing immediate postoperative stability and reducing complications related to stress concentration. However, the conclusions of current research should still be validated through in vitro mechanical tests and clinical trials.</abstract><cop>United States</cop><pmid>39636380</pmid><doi>10.1007/s10439-024-03643-5</doi></addata></record>
fulltext fulltext
identifier ISSN: 0090-6964
ispartof Annals of biomedical engineering, 2024-12
issn 0090-6964
1573-9686
1573-9686
language eng
recordid cdi_proquest_miscellaneous_3146531024
source Springer Nature
title An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T20%3A47%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20OLIF%20Cage%20Integrated%20with%20a%20Low-Profile%20Plate%20and%20Cross%20Screws%20Could%20Reduce%20the%20Risk%20of%20Postoperative%20Complications%20Biomechanically&rft.jtitle=Annals%20of%20biomedical%20engineering&rft.au=Cai,%20Ping&rft.date=2024-12-05&rft.issn=0090-6964&rft.eissn=1573-9686&rft_id=info:doi/10.1007/s10439-024-03643-5&rft_dat=%3Cproquest_cross%3E3146531024%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c184t-64702dc45fea46a108ff56f63784bfa4faf78e53c1d0dc5c1725b586598aa9133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3146531024&rft_id=info:pmid/39636380&rfr_iscdi=true