Loading…

Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID

•SPME-GC-BID method quantifies BTEX in exhaust gases effectively.•A new graduated vial device aids in sample extraction and dilution.•BID detector ensures high sensitivity in BTEX analysis.•Statistical validation ensures method reliability.•Method separates all BTEX, including xylene isomers. Benzen...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 2024-11, Vol.1736, p.465417, Article 465417
Main Authors: de Souza, Francisco T.C., da Silva, Maria Z.F., de Carvalho, Humberto H., Vidal, Carla B., do Nascimento, Ronaldo F., Longhinotti, Elisane
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c274t-110cd64febce222adea17b1acbb84fa17704eb20ae04ccc0bb38bdd46faa759b3
container_end_page
container_issue
container_start_page 465417
container_title Journal of Chromatography A
container_volume 1736
creator de Souza, Francisco T.C.
da Silva, Maria Z.F.
de Carvalho, Humberto H.
Vidal, Carla B.
do Nascimento, Ronaldo F.
Longhinotti, Elisane
description •SPME-GC-BID method quantifies BTEX in exhaust gases effectively.•A new graduated vial device aids in sample extraction and dilution.•BID detector ensures high sensitivity in BTEX analysis.•Statistical validation ensures method reliability.•Method separates all BTEX, including xylene isomers. Benzene, toluene, ethylbenzene, and the xylene isomers (m, p, and o-xylene) (BTEX) are known for their harmful effects on human health and have been extensively studied across various environmental matrices. However, quantifying BTEX in exhaust gases poses challenges due to the complexity of the matrices. In this study, we investigated a method development strategy involving solid-phase microextraction (SPME) and gas chromatography coupled with a dielectric barrier discharge ionization Detector (BID) for quantifying BTEX emitted from internal combustion engines operating at idle. Sampling was conducted using 1.0 L Tedlar bags, followed by withdrawal of aliquots and dilution with atmospheric air using a novel device (graduated vial) designed for gaseous samples. The SPME-GC-BID method was developed and validated for the conditions: BTEX extraction in CAR/PDMS 75 μm fiber at a contact time of 5.0 min at a temperature of 27 °C, followed by GC-BID analysis. Method validation to ensure the reliability of quantitative results used the merit figures e.g., limits of detection (LOD) and quantification (LOQ), precision, and accuracy (recovery). LOD varied from 0.194 to 0.340 mg m−3, LOQ varied from 0.587 to 1.03 mg m−3, precision ranged from 1.47 to 7.14 %, and recovery varied from 82.34 to 109.5 %. BTEX concentration in vehicle exhaust varied from 3.40 to 16.4 mg m−3. The results showed, concerning the figures of merit analyzed, that the SPME-GC-BID method provides good sensibility, precision, and accuracy for evaluating the presence of BTEX in the exhaust of internal combustion engines, contributing to the understanding of health risks associated with vehicle emissions. [Display omitted]
doi_str_mv 10.1016/j.chroma.2024.465417
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3153831804</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S002196732400791X</els_id><sourcerecordid>3153831804</sourcerecordid><originalsourceid>FETCH-LOGICAL-c274t-110cd64febce222adea17b1acbb84fa17704eb20ae04ccc0bb38bdd46faa759b3</originalsourceid><addsrcrecordid>eNp9kDFPwzAQhTOARCn8AwaPLAm24yYpA1JbQqlUBBJFQmKwzs65cZUmJU4q-PckhJnp3knvPd19nnfFaMAoi252gc7rag8Bp1wEIpoIFp94I0o586dRHJ55587tKGUxjfnI-0iPULTQ2HJL5pv0ndiSHDG3ukCCXzm0riFbcLdkRgx0GsqMoDFWWyy77XCoK9A5aV1f8PrylP46lgt_vrq_8E4NFA4v_-bYe3tIN4tHf_28XC1ma1_zWDQ-Y1RnkTCoNHLOIUNgsWKglUqE6XRMBSpOAanQWlOlwkRlmYgMQDyZqnDsXQ-93TGfLbpG7q3TWBRQYtU6GbJJmIQsoaKzisGq68q5Go081HYP9bdkVPb85E4O_GTPTw78utjdEMPujaPFWroegMbM1qgbmVX2_4IfB758rQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3153831804</pqid></control><display><type>article</type><title>Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID</title><source>Elsevier</source><creator>de Souza, Francisco T.C. ; da Silva, Maria Z.F. ; de Carvalho, Humberto H. ; Vidal, Carla B. ; do Nascimento, Ronaldo F. ; Longhinotti, Elisane</creator><creatorcontrib>de Souza, Francisco T.C. ; da Silva, Maria Z.F. ; de Carvalho, Humberto H. ; Vidal, Carla B. ; do Nascimento, Ronaldo F. ; Longhinotti, Elisane</creatorcontrib><description>•SPME-GC-BID method quantifies BTEX in exhaust gases effectively.•A new graduated vial device aids in sample extraction and dilution.•BID detector ensures high sensitivity in BTEX analysis.•Statistical validation ensures method reliability.•Method separates all BTEX, including xylene isomers. Benzene, toluene, ethylbenzene, and the xylene isomers (m, p, and o-xylene) (BTEX) are known for their harmful effects on human health and have been extensively studied across various environmental matrices. However, quantifying BTEX in exhaust gases poses challenges due to the complexity of the matrices. In this study, we investigated a method development strategy involving solid-phase microextraction (SPME) and gas chromatography coupled with a dielectric barrier discharge ionization Detector (BID) for quantifying BTEX emitted from internal combustion engines operating at idle. Sampling was conducted using 1.0 L Tedlar bags, followed by withdrawal of aliquots and dilution with atmospheric air using a novel device (graduated vial) designed for gaseous samples. The SPME-GC-BID method was developed and validated for the conditions: BTEX extraction in CAR/PDMS 75 μm fiber at a contact time of 5.0 min at a temperature of 27 °C, followed by GC-BID analysis. Method validation to ensure the reliability of quantitative results used the merit figures e.g., limits of detection (LOD) and quantification (LOQ), precision, and accuracy (recovery). LOD varied from 0.194 to 0.340 mg m−3, LOQ varied from 0.587 to 1.03 mg m−3, precision ranged from 1.47 to 7.14 %, and recovery varied from 82.34 to 109.5 %. BTEX concentration in vehicle exhaust varied from 3.40 to 16.4 mg m−3. The results showed, concerning the figures of merit analyzed, that the SPME-GC-BID method provides good sensibility, precision, and accuracy for evaluating the presence of BTEX in the exhaust of internal combustion engines, contributing to the understanding of health risks associated with vehicle emissions. [Display omitted]</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2024.465417</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>air ; Barrier ionization discharge detector ; benzene ; combustion ; ethylbenzene ; exhaust gas analysis ; gas chromatography ; human health ; ionization ; Monoaromatic hydrocarbons ; solid phase microextraction ; SPME sampling ; temperature ; toluene ; Vehicle emission ; xylene</subject><ispartof>Journal of Chromatography A, 2024-11, Vol.1736, p.465417, Article 465417</ispartof><rights>2024 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c274t-110cd64febce222adea17b1acbb84fa17704eb20ae04ccc0bb38bdd46faa759b3</cites><orcidid>0000-0002-4782-6905</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>de Souza, Francisco T.C.</creatorcontrib><creatorcontrib>da Silva, Maria Z.F.</creatorcontrib><creatorcontrib>de Carvalho, Humberto H.</creatorcontrib><creatorcontrib>Vidal, Carla B.</creatorcontrib><creatorcontrib>do Nascimento, Ronaldo F.</creatorcontrib><creatorcontrib>Longhinotti, Elisane</creatorcontrib><title>Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID</title><title>Journal of Chromatography A</title><description>•SPME-GC-BID method quantifies BTEX in exhaust gases effectively.•A new graduated vial device aids in sample extraction and dilution.•BID detector ensures high sensitivity in BTEX analysis.•Statistical validation ensures method reliability.•Method separates all BTEX, including xylene isomers. Benzene, toluene, ethylbenzene, and the xylene isomers (m, p, and o-xylene) (BTEX) are known for their harmful effects on human health and have been extensively studied across various environmental matrices. However, quantifying BTEX in exhaust gases poses challenges due to the complexity of the matrices. In this study, we investigated a method development strategy involving solid-phase microextraction (SPME) and gas chromatography coupled with a dielectric barrier discharge ionization Detector (BID) for quantifying BTEX emitted from internal combustion engines operating at idle. Sampling was conducted using 1.0 L Tedlar bags, followed by withdrawal of aliquots and dilution with atmospheric air using a novel device (graduated vial) designed for gaseous samples. The SPME-GC-BID method was developed and validated for the conditions: BTEX extraction in CAR/PDMS 75 μm fiber at a contact time of 5.0 min at a temperature of 27 °C, followed by GC-BID analysis. Method validation to ensure the reliability of quantitative results used the merit figures e.g., limits of detection (LOD) and quantification (LOQ), precision, and accuracy (recovery). LOD varied from 0.194 to 0.340 mg m−3, LOQ varied from 0.587 to 1.03 mg m−3, precision ranged from 1.47 to 7.14 %, and recovery varied from 82.34 to 109.5 %. BTEX concentration in vehicle exhaust varied from 3.40 to 16.4 mg m−3. The results showed, concerning the figures of merit analyzed, that the SPME-GC-BID method provides good sensibility, precision, and accuracy for evaluating the presence of BTEX in the exhaust of internal combustion engines, contributing to the understanding of health risks associated with vehicle emissions. [Display omitted]</description><subject>air</subject><subject>Barrier ionization discharge detector</subject><subject>benzene</subject><subject>combustion</subject><subject>ethylbenzene</subject><subject>exhaust gas analysis</subject><subject>gas chromatography</subject><subject>human health</subject><subject>ionization</subject><subject>Monoaromatic hydrocarbons</subject><subject>solid phase microextraction</subject><subject>SPME sampling</subject><subject>temperature</subject><subject>toluene</subject><subject>Vehicle emission</subject><subject>xylene</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kDFPwzAQhTOARCn8AwaPLAm24yYpA1JbQqlUBBJFQmKwzs65cZUmJU4q-PckhJnp3knvPd19nnfFaMAoi252gc7rag8Bp1wEIpoIFp94I0o586dRHJ55587tKGUxjfnI-0iPULTQ2HJL5pv0ndiSHDG3ukCCXzm0riFbcLdkRgx0GsqMoDFWWyy77XCoK9A5aV1f8PrylP46lgt_vrq_8E4NFA4v_-bYe3tIN4tHf_28XC1ma1_zWDQ-Y1RnkTCoNHLOIUNgsWKglUqE6XRMBSpOAanQWlOlwkRlmYgMQDyZqnDsXQ-93TGfLbpG7q3TWBRQYtU6GbJJmIQsoaKzisGq68q5Go081HYP9bdkVPb85E4O_GTPTw78utjdEMPujaPFWroegMbM1qgbmVX2_4IfB758rQ</recordid><startdate>20241108</startdate><enddate>20241108</enddate><creator>de Souza, Francisco T.C.</creator><creator>da Silva, Maria Z.F.</creator><creator>de Carvalho, Humberto H.</creator><creator>Vidal, Carla B.</creator><creator>do Nascimento, Ronaldo F.</creator><creator>Longhinotti, Elisane</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7S9</scope><scope>L.6</scope><orcidid>https://orcid.org/0000-0002-4782-6905</orcidid></search><sort><creationdate>20241108</creationdate><title>Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID</title><author>de Souza, Francisco T.C. ; da Silva, Maria Z.F. ; de Carvalho, Humberto H. ; Vidal, Carla B. ; do Nascimento, Ronaldo F. ; Longhinotti, Elisane</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c274t-110cd64febce222adea17b1acbb84fa17704eb20ae04ccc0bb38bdd46faa759b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>air</topic><topic>Barrier ionization discharge detector</topic><topic>benzene</topic><topic>combustion</topic><topic>ethylbenzene</topic><topic>exhaust gas analysis</topic><topic>gas chromatography</topic><topic>human health</topic><topic>ionization</topic><topic>Monoaromatic hydrocarbons</topic><topic>solid phase microextraction</topic><topic>SPME sampling</topic><topic>temperature</topic><topic>toluene</topic><topic>Vehicle emission</topic><topic>xylene</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Souza, Francisco T.C.</creatorcontrib><creatorcontrib>da Silva, Maria Z.F.</creatorcontrib><creatorcontrib>de Carvalho, Humberto H.</creatorcontrib><creatorcontrib>Vidal, Carla B.</creatorcontrib><creatorcontrib>do Nascimento, Ronaldo F.</creatorcontrib><creatorcontrib>Longhinotti, Elisane</creatorcontrib><collection>CrossRef</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Souza, Francisco T.C.</au><au>da Silva, Maria Z.F.</au><au>de Carvalho, Humberto H.</au><au>Vidal, Carla B.</au><au>do Nascimento, Ronaldo F.</au><au>Longhinotti, Elisane</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID</atitle><jtitle>Journal of Chromatography A</jtitle><date>2024-11-08</date><risdate>2024</risdate><volume>1736</volume><spage>465417</spage><pages>465417-</pages><artnum>465417</artnum><issn>0021-9673</issn><abstract>•SPME-GC-BID method quantifies BTEX in exhaust gases effectively.•A new graduated vial device aids in sample extraction and dilution.•BID detector ensures high sensitivity in BTEX analysis.•Statistical validation ensures method reliability.•Method separates all BTEX, including xylene isomers. Benzene, toluene, ethylbenzene, and the xylene isomers (m, p, and o-xylene) (BTEX) are known for their harmful effects on human health and have been extensively studied across various environmental matrices. However, quantifying BTEX in exhaust gases poses challenges due to the complexity of the matrices. In this study, we investigated a method development strategy involving solid-phase microextraction (SPME) and gas chromatography coupled with a dielectric barrier discharge ionization Detector (BID) for quantifying BTEX emitted from internal combustion engines operating at idle. Sampling was conducted using 1.0 L Tedlar bags, followed by withdrawal of aliquots and dilution with atmospheric air using a novel device (graduated vial) designed for gaseous samples. The SPME-GC-BID method was developed and validated for the conditions: BTEX extraction in CAR/PDMS 75 μm fiber at a contact time of 5.0 min at a temperature of 27 °C, followed by GC-BID analysis. Method validation to ensure the reliability of quantitative results used the merit figures e.g., limits of detection (LOD) and quantification (LOQ), precision, and accuracy (recovery). LOD varied from 0.194 to 0.340 mg m−3, LOQ varied from 0.587 to 1.03 mg m−3, precision ranged from 1.47 to 7.14 %, and recovery varied from 82.34 to 109.5 %. BTEX concentration in vehicle exhaust varied from 3.40 to 16.4 mg m−3. The results showed, concerning the figures of merit analyzed, that the SPME-GC-BID method provides good sensibility, precision, and accuracy for evaluating the presence of BTEX in the exhaust of internal combustion engines, contributing to the understanding of health risks associated with vehicle emissions. [Display omitted]</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.chroma.2024.465417</doi><orcidid>https://orcid.org/0000-0002-4782-6905</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2024-11, Vol.1736, p.465417, Article 465417
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_3153831804
source Elsevier
subjects air
Barrier ionization discharge detector
benzene
combustion
ethylbenzene
exhaust gas analysis
gas chromatography
human health
ionization
Monoaromatic hydrocarbons
solid phase microextraction
SPME sampling
temperature
toluene
Vehicle emission
xylene
title Evaluating BTEX in vehicle exhaust gas: A fast and efficient approach using SPME and GC-BID
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T02%3A56%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluating%20BTEX%20in%20vehicle%20exhaust%20gas:%20A%20fast%20and%20efficient%20approach%20using%20SPME%20and%20GC-BID&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=de%20Souza,%20Francisco%20T.C.&rft.date=2024-11-08&rft.volume=1736&rft.spage=465417&rft.pages=465417-&rft.artnum=465417&rft.issn=0021-9673&rft_id=info:doi/10.1016/j.chroma.2024.465417&rft_dat=%3Cproquest_cross%3E3153831804%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c274t-110cd64febce222adea17b1acbb84fa17704eb20ae04ccc0bb38bdd46faa759b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3153831804&rft_id=info:pmid/&rfr_iscdi=true