Effects of packing density, excess water and solid surface area on flowability of cement paste

Although it has been postulated for many years that it is excess water rather than whole water that lubricates the cementitious materials and governs flowability of paste (excess water is water in excess of that needed to fill up voids), there has been no detailed investigations to study the actual...

Full description

Saved in:
Bibliographic Details
Published in:Advances in cement research 2008, Vol.20 (1), p.1-11
Main Authors: KWAN, A. K. H, WONG, H. H. C
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673
cites cdi_FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673
container_end_page 11
container_issue 1
container_start_page 1
container_title Advances in cement research
container_volume 20
creator KWAN, A. K. H
WONG, H. H. C
description Although it has been postulated for many years that it is excess water rather than whole water that lubricates the cementitious materials and governs flowability of paste (excess water is water in excess of that needed to fill up voids), there has been no detailed investigations to study the actual effects of excess water. This was due to the lack of a suitable method for measuring the packing density and voids content of cementitious materials. To resolve the problem, the authors have recently developed a new wet packing method that was applied herein to measure the packing densities and voids contents of cementitious materials containing different amounts of cement, pulverised fuel ash and condensed silica fume. The flowability properties of the paste formed of the cementitious materials with different water contents were also measured and correlated to the excess water contents, each determined as water content minus voids content. The results revealed that whereas an improvement in packing density would increase excess water content, flowability is governed mainly by excess water to solid volume and excess water to solid surface area ratios.
doi_str_mv 10.1680/adcr.2008.20.1.1
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_31754057</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>31754057</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673</originalsourceid><addsrcrecordid>eNo9kL9PwzAQhS0EEqWwM3qBiQQ7TuJ4RFX5IVVigRXrYp9RIE2KL1Xpf0-iVizvbnjvGz7GrqVIZVmJe_AuppkQ1RipTOUJm0ldyESXojhlM2GmXxp9zi6IvoSQmS7VjH0sQ0A3EO8D34D7brpP7rGjZtjfcfx1SMR3MGDk0HlOfduMuY0BHHKICLzveGj7HdRNO24mjMM1dsNIowEv2VmAlvDqeOfs_XH5tnhOVq9PL4uHVeKUFkNSe1MolykodSUzWVfKo8q8cbXJjJTOe-20yoWBYLCuvEBdl4haIlS5LrWas9sDdxP7ny3SYNcNOWxb6LDfklWji1wUU1Ecii72RBGD3cRmDXFvpbCTSDuJtJPIMay0cpzcHNlADtoQoXMN_e_Gqsp0btQfEkR06Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>31754057</pqid></control><display><type>article</type><title>Effects of packing density, excess water and solid surface area on flowability of cement paste</title><source>Institution of Civil Engineers</source><creator>KWAN, A. K. H ; WONG, H. H. C</creator><creatorcontrib>KWAN, A. K. H ; WONG, H. H. C</creatorcontrib><description>Although it has been postulated for many years that it is excess water rather than whole water that lubricates the cementitious materials and governs flowability of paste (excess water is water in excess of that needed to fill up voids), there has been no detailed investigations to study the actual effects of excess water. This was due to the lack of a suitable method for measuring the packing density and voids content of cementitious materials. To resolve the problem, the authors have recently developed a new wet packing method that was applied herein to measure the packing densities and voids contents of cementitious materials containing different amounts of cement, pulverised fuel ash and condensed silica fume. The flowability properties of the paste formed of the cementitious materials with different water contents were also measured and correlated to the excess water contents, each determined as water content minus voids content. The results revealed that whereas an improvement in packing density would increase excess water content, flowability is governed mainly by excess water to solid volume and excess water to solid surface area ratios.</description><identifier>ISSN: 0951-7197</identifier><identifier>EISSN: 1751-7605</identifier><identifier>DOI: 10.1680/adcr.2008.20.1.1</identifier><language>eng</language><publisher>London: Telford</publisher><subject>Applied sciences ; Buildings. Public works ; Cement concrete constituents ; Cements ; Exact sciences and technology ; Materials ; Properties and test methods ; Properties of anhydrous and hydrated cement, test methods</subject><ispartof>Advances in cement research, 2008, Vol.20 (1), p.1-11</ispartof><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673</citedby><cites>FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=20032749$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>KWAN, A. K. H</creatorcontrib><creatorcontrib>WONG, H. H. C</creatorcontrib><title>Effects of packing density, excess water and solid surface area on flowability of cement paste</title><title>Advances in cement research</title><description>Although it has been postulated for many years that it is excess water rather than whole water that lubricates the cementitious materials and governs flowability of paste (excess water is water in excess of that needed to fill up voids), there has been no detailed investigations to study the actual effects of excess water. This was due to the lack of a suitable method for measuring the packing density and voids content of cementitious materials. To resolve the problem, the authors have recently developed a new wet packing method that was applied herein to measure the packing densities and voids contents of cementitious materials containing different amounts of cement, pulverised fuel ash and condensed silica fume. The flowability properties of the paste formed of the cementitious materials with different water contents were also measured and correlated to the excess water contents, each determined as water content minus voids content. The results revealed that whereas an improvement in packing density would increase excess water content, flowability is governed mainly by excess water to solid volume and excess water to solid surface area ratios.</description><subject>Applied sciences</subject><subject>Buildings. Public works</subject><subject>Cement concrete constituents</subject><subject>Cements</subject><subject>Exact sciences and technology</subject><subject>Materials</subject><subject>Properties and test methods</subject><subject>Properties of anhydrous and hydrated cement, test methods</subject><issn>0951-7197</issn><issn>1751-7605</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNo9kL9PwzAQhS0EEqWwM3qBiQQ7TuJ4RFX5IVVigRXrYp9RIE2KL1Xpf0-iVizvbnjvGz7GrqVIZVmJe_AuppkQ1RipTOUJm0ldyESXojhlM2GmXxp9zi6IvoSQmS7VjH0sQ0A3EO8D34D7brpP7rGjZtjfcfx1SMR3MGDk0HlOfduMuY0BHHKICLzveGj7HdRNO24mjMM1dsNIowEv2VmAlvDqeOfs_XH5tnhOVq9PL4uHVeKUFkNSe1MolykodSUzWVfKo8q8cbXJjJTOe-20yoWBYLCuvEBdl4haIlS5LrWas9sDdxP7ny3SYNcNOWxb6LDfklWji1wUU1Ecii72RBGD3cRmDXFvpbCTSDuJtJPIMay0cpzcHNlADtoQoXMN_e_Gqsp0btQfEkR06Q</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>KWAN, A. K. H</creator><creator>WONG, H. H. C</creator><general>Telford</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QQ</scope><scope>7SR</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>JG9</scope><scope>KR7</scope></search><sort><creationdate>2008</creationdate><title>Effects of packing density, excess water and solid surface area on flowability of cement paste</title><author>KWAN, A. K. H ; WONG, H. H. C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Applied sciences</topic><topic>Buildings. Public works</topic><topic>Cement concrete constituents</topic><topic>Cements</topic><topic>Exact sciences and technology</topic><topic>Materials</topic><topic>Properties and test methods</topic><topic>Properties of anhydrous and hydrated cement, test methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KWAN, A. K. H</creatorcontrib><creatorcontrib>WONG, H. H. C</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Ceramic Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Advances in cement research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KWAN, A. K. H</au><au>WONG, H. H. C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of packing density, excess water and solid surface area on flowability of cement paste</atitle><jtitle>Advances in cement research</jtitle><date>2008</date><risdate>2008</risdate><volume>20</volume><issue>1</issue><spage>1</spage><epage>11</epage><pages>1-11</pages><issn>0951-7197</issn><eissn>1751-7605</eissn><abstract>Although it has been postulated for many years that it is excess water rather than whole water that lubricates the cementitious materials and governs flowability of paste (excess water is water in excess of that needed to fill up voids), there has been no detailed investigations to study the actual effects of excess water. This was due to the lack of a suitable method for measuring the packing density and voids content of cementitious materials. To resolve the problem, the authors have recently developed a new wet packing method that was applied herein to measure the packing densities and voids contents of cementitious materials containing different amounts of cement, pulverised fuel ash and condensed silica fume. The flowability properties of the paste formed of the cementitious materials with different water contents were also measured and correlated to the excess water contents, each determined as water content minus voids content. The results revealed that whereas an improvement in packing density would increase excess water content, flowability is governed mainly by excess water to solid volume and excess water to solid surface area ratios.</abstract><cop>London</cop><pub>Telford</pub><doi>10.1680/adcr.2008.20.1.1</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0951-7197
ispartof Advances in cement research, 2008, Vol.20 (1), p.1-11
issn 0951-7197
1751-7605
language eng
recordid cdi_proquest_miscellaneous_31754057
source Institution of Civil Engineers
subjects Applied sciences
Buildings. Public works
Cement concrete constituents
Cements
Exact sciences and technology
Materials
Properties and test methods
Properties of anhydrous and hydrated cement, test methods
title Effects of packing density, excess water and solid surface area on flowability of cement paste
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-23T23%3A02%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20packing%20density,%20excess%20water%20and%20solid%20surface%20area%20on%20flowability%20of%20cement%20paste&rft.jtitle=Advances%20in%20cement%20research&rft.au=KWAN,%20A.%20K.%20H&rft.date=2008&rft.volume=20&rft.issue=1&rft.spage=1&rft.epage=11&rft.pages=1-11&rft.issn=0951-7197&rft.eissn=1751-7605&rft_id=info:doi/10.1680/adcr.2008.20.1.1&rft_dat=%3Cproquest_cross%3E31754057%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c370t-bd953c23a678121b83de32d9cb92911cdd7c73409af9eb8d0e7b6ee71ea847673%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=31754057&rft_id=info:pmid/&rfr_iscdi=true