Rupture pressure of wear degraded alloy 600 steam generator tubings
Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195 mm in length. A pressure test was carried out with the tubes at room temperature by using a hi...
Saved in:
Published in: | Journal of nuclear materials 2008-02, Vol.373 (1), p.71-74 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593 |
---|---|
cites | cdi_FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593 |
container_end_page | 74 |
container_issue | 1 |
container_start_page | 71 |
container_title | Journal of nuclear materials |
container_volume | 373 |
creator | Hwang, Seong Sik Namgung, Chan Jung, Man Kyo Kim, Hong Pyo Kim, Joung Soo |
description | Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195
mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture. |
doi_str_mv | 10.1016/j.jnucmat.2007.05.020 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_31869387</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022311507007921</els_id><sourcerecordid>20261878</sourcerecordid><originalsourceid>FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593</originalsourceid><addsrcrecordid>eNqFkMtKxEAQRRtRcBz9BCEb3SVWPyqPlcjgCwYE0XXT6VSGhLzsThT_3oQZ3M6qanFuXeowds0h4sDjuzqqu8m2ZowEQBIBRiDghK14mshQpQJO2QpAiFByjufswvsaADADXLHN-zSMk6NgcOT9svRl8EPGBQXtnCmoCEzT9L9BDBD4kUwb7KgjZ8beBeOUV93OX7Kz0jSerg5zzT6fHj82L-H27fl187ANrQI-hgrTHMAmRimZYCYyqzgKMjlPhEktyTyJrUJUtowTxEJKIiV4XhIXaDGTa3a7vzu4_msiP-q28paaxnTUT15LnsaZnJ8-BgoQ8SwnnUHcg9b13jsq9eCq1rhfzUEvbnWtD2714lYD6tntnLs5FBhvTVM609nK_4dnVKSIC3e_52jW8l2R095W1FkqKkd21EVfHWn6AyjqkMY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20261878</pqid></control><display><type>article</type><title>Rupture pressure of wear degraded alloy 600 steam generator tubings</title><source>ScienceDirect Freedom Collection</source><creator>Hwang, Seong Sik ; Namgung, Chan ; Jung, Man Kyo ; Kim, Hong Pyo ; Kim, Joung Soo</creator><creatorcontrib>Hwang, Seong Sik ; Namgung, Chan ; Jung, Man Kyo ; Kim, Hong Pyo ; Kim, Joung Soo</creatorcontrib><description>Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195
mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.</description><identifier>ISSN: 0022-3115</identifier><identifier>EISSN: 1873-4820</identifier><identifier>DOI: 10.1016/j.jnucmat.2007.05.020</identifier><identifier>CODEN: JNUMAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Controled nuclear fusion plants ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Fission nuclear power plants ; Fuels ; Installations for energy generation and conversion: thermal and electrical energy ; Nuclear fuels</subject><ispartof>Journal of nuclear materials, 2008-02, Vol.373 (1), p.71-74</ispartof><rights>2007</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593</citedby><cites>FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20028550$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Hwang, Seong Sik</creatorcontrib><creatorcontrib>Namgung, Chan</creatorcontrib><creatorcontrib>Jung, Man Kyo</creatorcontrib><creatorcontrib>Kim, Hong Pyo</creatorcontrib><creatorcontrib>Kim, Joung Soo</creatorcontrib><title>Rupture pressure of wear degraded alloy 600 steam generator tubings</title><title>Journal of nuclear materials</title><description>Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195
mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.</description><subject>Applied sciences</subject><subject>Controled nuclear fusion plants</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Fission nuclear power plants</subject><subject>Fuels</subject><subject>Installations for energy generation and conversion: thermal and electrical energy</subject><subject>Nuclear fuels</subject><issn>0022-3115</issn><issn>1873-4820</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkMtKxEAQRRtRcBz9BCEb3SVWPyqPlcjgCwYE0XXT6VSGhLzsThT_3oQZ3M6qanFuXeowds0h4sDjuzqqu8m2ZowEQBIBRiDghK14mshQpQJO2QpAiFByjufswvsaADADXLHN-zSMk6NgcOT9svRl8EPGBQXtnCmoCEzT9L9BDBD4kUwb7KgjZ8beBeOUV93OX7Kz0jSerg5zzT6fHj82L-H27fl187ANrQI-hgrTHMAmRimZYCYyqzgKMjlPhEktyTyJrUJUtowTxEJKIiV4XhIXaDGTa3a7vzu4_msiP-q28paaxnTUT15LnsaZnJ8-BgoQ8SwnnUHcg9b13jsq9eCq1rhfzUEvbnWtD2714lYD6tntnLs5FBhvTVM609nK_4dnVKSIC3e_52jW8l2R095W1FkqKkd21EVfHWn6AyjqkMY</recordid><startdate>20080215</startdate><enddate>20080215</enddate><creator>Hwang, Seong Sik</creator><creator>Namgung, Chan</creator><creator>Jung, Man Kyo</creator><creator>Kim, Hong Pyo</creator><creator>Kim, Joung Soo</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope><scope>SOI</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20080215</creationdate><title>Rupture pressure of wear degraded alloy 600 steam generator tubings</title><author>Hwang, Seong Sik ; Namgung, Chan ; Jung, Man Kyo ; Kim, Hong Pyo ; Kim, Joung Soo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Applied sciences</topic><topic>Controled nuclear fusion plants</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Fission nuclear power plants</topic><topic>Fuels</topic><topic>Installations for energy generation and conversion: thermal and electrical energy</topic><topic>Nuclear fuels</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hwang, Seong Sik</creatorcontrib><creatorcontrib>Namgung, Chan</creatorcontrib><creatorcontrib>Jung, Man Kyo</creatorcontrib><creatorcontrib>Kim, Hong Pyo</creatorcontrib><creatorcontrib>Kim, Joung Soo</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of nuclear materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hwang, Seong Sik</au><au>Namgung, Chan</au><au>Jung, Man Kyo</au><au>Kim, Hong Pyo</au><au>Kim, Joung Soo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rupture pressure of wear degraded alloy 600 steam generator tubings</atitle><jtitle>Journal of nuclear materials</jtitle><date>2008-02-15</date><risdate>2008</risdate><volume>373</volume><issue>1</issue><spage>71</spage><epage>74</epage><pages>71-74</pages><issn>0022-3115</issn><eissn>1873-4820</eissn><coden>JNUMAM</coden><abstract>Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195
mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.jnucmat.2007.05.020</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3115 |
ispartof | Journal of nuclear materials, 2008-02, Vol.373 (1), p.71-74 |
issn | 0022-3115 1873-4820 |
language | eng |
recordid | cdi_proquest_miscellaneous_31869387 |
source | ScienceDirect Freedom Collection |
subjects | Applied sciences Controled nuclear fusion plants Energy Energy. Thermal use of fuels Exact sciences and technology Fission nuclear power plants Fuels Installations for energy generation and conversion: thermal and electrical energy Nuclear fuels |
title | Rupture pressure of wear degraded alloy 600 steam generator tubings |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T05%3A39%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rupture%20pressure%20of%20wear%20degraded%20alloy%20600%20steam%20generator%20tubings&rft.jtitle=Journal%20of%20nuclear%20materials&rft.au=Hwang,%20Seong%20Sik&rft.date=2008-02-15&rft.volume=373&rft.issue=1&rft.spage=71&rft.epage=74&rft.pages=71-74&rft.issn=0022-3115&rft.eissn=1873-4820&rft.coden=JNUMAM&rft_id=info:doi/10.1016/j.jnucmat.2007.05.020&rft_dat=%3Cproquest_cross%3E20261878%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c401t-458b00c7a44375929c4152eab172a8ce3b76c4554cf6755d33ee421bfe125c593%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20261878&rft_id=info:pmid/&rfr_iscdi=true |