Loading…

Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert

In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to...

Full description

Saved in:
Bibliographic Details
Published in:International journal of heat and mass transfer 2009-03, Vol.52 (7), p.1938-1944
Main Authors: Bharadwaj, P., Khondge, A.D., Date, A.W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743
cites cdi_FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743
container_end_page 1944
container_issue 7
container_start_page 1938
container_title International journal of heat and mass transfer
container_volume 52
creator Bharadwaj, P.
Khondge, A.D.
Date, A.W.
description In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to the direction of flow. Compared to smooth tube, the heat transfer enhancement due to spiral grooves is further augmented by inserting twisted tapes having twist ratios Y ≃ 10.15, 7.95 and 3.4. It is found that the direction of twist (clockwise and anticlockwise) influences the thermo-hydraulic characteristics. Constant pumping power comparisons with smooth tube characteristics show that in spirally grooved tube with and without twisted tape, heat transfer increases considerably in laminar and moderately in turbulent range of Reynolds numbers. However, for the bare spiral tube and for spiral tube with anticlockwise twisted tape ( Y = 10.15), reduction in heat transfer is noticed over a transition range of Reynolds numbers.
doi_str_mv 10.1016/j.ijheatmasstransfer.2008.08.038
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_33227236</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0017931008006066</els_id><sourcerecordid>33227236</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743</originalsourceid><addsrcrecordid>eNqNkE9Lw0AQxRdRsFa_w57ES-L-abKbm1LUKgUP6nnZbCZ2S5rEnW1Lv70J1ZMX4cEwM48fvEfIDWcpZzy_Xad-vQIbNxYxBttiDSEVjOl0lNQnZMK1KhLBdXFKJoxxlRSSs3NygbgeVzbLJ-RtMTDoL4DatqJ9AMRtAFqFrqe-pZZi74NtmgP9DF23g4rGbQl07-OKxr3HOF5sD4MZIcRLclbbBuHqZ07Jx-PD-3yRLF-fnuf3y8RJJWMiSu2qSopMc-5kVihnS6WdKzPNMlHZuhZC5koWzHKb51rlqpy5sijzTFmhZnJKro_cPnRfW8BoNh4dNI1toduikVIINSAG493R6EKHGKA2ffAbGw6GMzO2adbmb5tmbNOMknpAvBwRMATa-eGLzkProPIBXDRV5_8P-wYBUYuQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>33227236</pqid></control><display><type>article</type><title>Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert</title><source>ScienceDirect Journals</source><creator>Bharadwaj, P. ; Khondge, A.D. ; Date, A.W.</creator><creatorcontrib>Bharadwaj, P. ; Khondge, A.D. ; Date, A.W.</creatorcontrib><description>In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to the direction of flow. Compared to smooth tube, the heat transfer enhancement due to spiral grooves is further augmented by inserting twisted tapes having twist ratios Y ≃ 10.15, 7.95 and 3.4. It is found that the direction of twist (clockwise and anticlockwise) influences the thermo-hydraulic characteristics. Constant pumping power comparisons with smooth tube characteristics show that in spirally grooved tube with and without twisted tape, heat transfer increases considerably in laminar and moderately in turbulent range of Reynolds numbers. However, for the bare spiral tube and for spiral tube with anticlockwise twisted tape ( Y = 10.15), reduction in heat transfer is noticed over a transition range of Reynolds numbers.</description><identifier>ISSN: 0017-9310</identifier><identifier>EISSN: 1879-2189</identifier><identifier>DOI: 10.1016/j.ijheatmasstransfer.2008.08.038</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Compound heat transfer enhancement ; Spirally grooved tube ; Twisted tape insert</subject><ispartof>International journal of heat and mass transfer, 2009-03, Vol.52 (7), p.1938-1944</ispartof><rights>2008 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743</citedby><cites>FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Bharadwaj, P.</creatorcontrib><creatorcontrib>Khondge, A.D.</creatorcontrib><creatorcontrib>Date, A.W.</creatorcontrib><title>Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert</title><title>International journal of heat and mass transfer</title><description>In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to the direction of flow. Compared to smooth tube, the heat transfer enhancement due to spiral grooves is further augmented by inserting twisted tapes having twist ratios Y ≃ 10.15, 7.95 and 3.4. It is found that the direction of twist (clockwise and anticlockwise) influences the thermo-hydraulic characteristics. Constant pumping power comparisons with smooth tube characteristics show that in spirally grooved tube with and without twisted tape, heat transfer increases considerably in laminar and moderately in turbulent range of Reynolds numbers. However, for the bare spiral tube and for spiral tube with anticlockwise twisted tape ( Y = 10.15), reduction in heat transfer is noticed over a transition range of Reynolds numbers.</description><subject>Compound heat transfer enhancement</subject><subject>Spirally grooved tube</subject><subject>Twisted tape insert</subject><issn>0017-9310</issn><issn>1879-2189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqNkE9Lw0AQxRdRsFa_w57ES-L-abKbm1LUKgUP6nnZbCZ2S5rEnW1Lv70J1ZMX4cEwM48fvEfIDWcpZzy_Xad-vQIbNxYxBttiDSEVjOl0lNQnZMK1KhLBdXFKJoxxlRSSs3NygbgeVzbLJ-RtMTDoL4DatqJ9AMRtAFqFrqe-pZZi74NtmgP9DF23g4rGbQl07-OKxr3HOF5sD4MZIcRLclbbBuHqZ07Jx-PD-3yRLF-fnuf3y8RJJWMiSu2qSopMc-5kVihnS6WdKzPNMlHZuhZC5koWzHKb51rlqpy5sijzTFmhZnJKro_cPnRfW8BoNh4dNI1toduikVIINSAG493R6EKHGKA2ffAbGw6GMzO2adbmb5tmbNOMknpAvBwRMATa-eGLzkProPIBXDRV5_8P-wYBUYuQ</recordid><startdate>20090301</startdate><enddate>20090301</enddate><creator>Bharadwaj, P.</creator><creator>Khondge, A.D.</creator><creator>Date, A.W.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20090301</creationdate><title>Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert</title><author>Bharadwaj, P. ; Khondge, A.D. ; Date, A.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Compound heat transfer enhancement</topic><topic>Spirally grooved tube</topic><topic>Twisted tape insert</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bharadwaj, P.</creatorcontrib><creatorcontrib>Khondge, A.D.</creatorcontrib><creatorcontrib>Date, A.W.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>International journal of heat and mass transfer</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bharadwaj, P.</au><au>Khondge, A.D.</au><au>Date, A.W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert</atitle><jtitle>International journal of heat and mass transfer</jtitle><date>2009-03-01</date><risdate>2009</risdate><volume>52</volume><issue>7</issue><spage>1938</spage><epage>1944</epage><pages>1938-1944</pages><issn>0017-9310</issn><eissn>1879-2189</eissn><abstract>In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to the direction of flow. Compared to smooth tube, the heat transfer enhancement due to spiral grooves is further augmented by inserting twisted tapes having twist ratios Y ≃ 10.15, 7.95 and 3.4. It is found that the direction of twist (clockwise and anticlockwise) influences the thermo-hydraulic characteristics. Constant pumping power comparisons with smooth tube characteristics show that in spirally grooved tube with and without twisted tape, heat transfer increases considerably in laminar and moderately in turbulent range of Reynolds numbers. However, for the bare spiral tube and for spiral tube with anticlockwise twisted tape ( Y = 10.15), reduction in heat transfer is noticed over a transition range of Reynolds numbers.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ijheatmasstransfer.2008.08.038</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0017-9310
ispartof International journal of heat and mass transfer, 2009-03, Vol.52 (7), p.1938-1944
issn 0017-9310
1879-2189
language eng
recordid cdi_proquest_miscellaneous_33227236
source ScienceDirect Journals
subjects Compound heat transfer enhancement
Spirally grooved tube
Twisted tape insert
title Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T09%3A52%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Heat%20transfer%20and%20pressure%20drop%20in%20a%20spirally%20grooved%20tube%20with%20twisted%20tape%20insert&rft.jtitle=International%20journal%20of%20heat%20and%20mass%20transfer&rft.au=Bharadwaj,%20P.&rft.date=2009-03-01&rft.volume=52&rft.issue=7&rft.spage=1938&rft.epage=1944&rft.pages=1938-1944&rft.issn=0017-9310&rft.eissn=1879-2189&rft_id=info:doi/10.1016/j.ijheatmasstransfer.2008.08.038&rft_dat=%3Cproquest_cross%3E33227236%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c373t-2b8cdd325811c3597cab78ccb58052daff22367390a1a668767b4cb9b657a2743%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=33227236&rft_id=info:pmid/&rfr_iscdi=true