Loading…

TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry

The TiC working electrode was tested as a novel, potential electrode for anodic stripping voltammetric determination of lead(II) ions traces. To demonstrate the practical applicability of the TiC electrode, an underpotential deposition/dissolution (UPD) phenomena system in electrolyte without remova...

Full description

Saved in:
Bibliographic Details
Published in:Electroanalysis (New York, N.Y.) N.Y.), 2008-08, Vol.20 (15), p.1655-1664
Main Authors: Baś, B., Piech, R., Niewiara, E., Ziemnicka, M., Stobierski, L., Kubiak, W. W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323
cites cdi_FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323
container_end_page 1664
container_issue 15
container_start_page 1655
container_title Electroanalysis (New York, N.Y.)
container_volume 20
creator Baś, B.
Piech, R.
Niewiara, E.
Ziemnicka, M.
Stobierski, L.
Kubiak, W. W.
description The TiC working electrode was tested as a novel, potential electrode for anodic stripping voltammetric determination of lead(II) ions traces. To demonstrate the practical applicability of the TiC electrode, an underpotential deposition/dissolution (UPD) phenomena system in electrolyte without removal of oxygen was tested. The electrode was constructed be means of mounting a TiC disk (Ø=3.5 mm) in a resin body. Three compositions of TiC were tested differing in stoichiometry, namely TiC0.6, TiC0.8, and TiC1.0. The key problem is the method of electrochemical activation of the TiC electrode. No or improperly activated electrode is not polarized and is unsuitable as a voltammetric sensor. The TiC electrode was used for the determination of Pb2+ in concentrations ranging from 1 to 100 nM. The instrumental parameters, composition of supporting electrolyte and procedures of the electrode activation were optimized. The repeatability of DP ASV runs in synthetic solutions covering the entire concentration range is better than 3%. The calibration curve is characterized by a correlation coefficient of at least 0.999. The detection limit was 2 nM for an electrodeposition time of 30 s. The method enables determination of Pb2+ in the presence of, among the others, high excesses of Cd, Cu, In, Sb, Se, and Tl ions as well as surfactants, Triton X‐100 and humic acids. The analysis of Pb2+ in synthetic solutions with and without surfactants, certified reference material and natural water samples have been performed. The voltammetric data were associated with the structural characterization of the electrode surface using scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).
doi_str_mv 10.1002/elan.200804229
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_34053348</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34053348</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323</originalsourceid><addsrcrecordid>eNqFkE1P3DAQhiPUSqW015596i3L-CMfPq7Cdqm0pRIsIPVieZ0xdUni1A4qe-h_r1epgBunscbv8470ZNknCgsKwE6x08OCAdQgGJNH2TEtGM0FBfkmvUFADlxW77L3Mf4CAFkKeZz93bqG3Ppw74Y7surQTMG3uCA3vpt03-MUnCHNTx20mTC4ODkTiR5ashzHzhk9OT8Q6wM5w_Tfu2HeeEs2qFuyTRxGstuTq9Q0jocrz9X7D9lbq7uIH__Pk-z6y2rbnOeb7-uvzXKTGy4LmdcItoSKCzC8lai5kaApllxCxViNFm1LkeLOCt2yFqWxgovW7GpZmJozfpJ9nnvH4H8_YJxU76LBLhlD_xBVai44F3UKLuagCT7GgFaNwfU67BUFdbCsDpbVk-UEyBn44zrcv5JWq83y4iWbz2zSio9PrA73qqx4Vajbi7Wqyku6bn6s1Tf-D2ohkys</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34053348</pqid></control><display><type>article</type><title>TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Baś, B. ; Piech, R. ; Niewiara, E. ; Ziemnicka, M. ; Stobierski, L. ; Kubiak, W. W.</creator><creatorcontrib>Baś, B. ; Piech, R. ; Niewiara, E. ; Ziemnicka, M. ; Stobierski, L. ; Kubiak, W. W.</creatorcontrib><description>The TiC working electrode was tested as a novel, potential electrode for anodic stripping voltammetric determination of lead(II) ions traces. To demonstrate the practical applicability of the TiC electrode, an underpotential deposition/dissolution (UPD) phenomena system in electrolyte without removal of oxygen was tested. The electrode was constructed be means of mounting a TiC disk (Ø=3.5 mm) in a resin body. Three compositions of TiC were tested differing in stoichiometry, namely TiC0.6, TiC0.8, and TiC1.0. The key problem is the method of electrochemical activation of the TiC electrode. No or improperly activated electrode is not polarized and is unsuitable as a voltammetric sensor. The TiC electrode was used for the determination of Pb2+ in concentrations ranging from 1 to 100 nM. The instrumental parameters, composition of supporting electrolyte and procedures of the electrode activation were optimized. The repeatability of DP ASV runs in synthetic solutions covering the entire concentration range is better than 3%. The calibration curve is characterized by a correlation coefficient of at least 0.999. The detection limit was 2 nM for an electrodeposition time of 30 s. The method enables determination of Pb2+ in the presence of, among the others, high excesses of Cd, Cu, In, Sb, Se, and Tl ions as well as surfactants, Triton X‐100 and humic acids. The analysis of Pb2+ in synthetic solutions with and without surfactants, certified reference material and natural water samples have been performed. The voltammetric data were associated with the structural characterization of the electrode surface using scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.200804229</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Lead ; Mercury-free electroanalysis ; Stripping voltammetry ; Titanium carbide ; Trace analysis ; Underpotential deposition</subject><ispartof>Electroanalysis (New York, N.Y.), 2008-08, Vol.20 (15), p.1655-1664</ispartof><rights>Copyright © 2008 WILEY‐VCH Verlag GmbH &amp; Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323</citedby><cites>FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Baś, B.</creatorcontrib><creatorcontrib>Piech, R.</creatorcontrib><creatorcontrib>Niewiara, E.</creatorcontrib><creatorcontrib>Ziemnicka, M.</creatorcontrib><creatorcontrib>Stobierski, L.</creatorcontrib><creatorcontrib>Kubiak, W. W.</creatorcontrib><title>TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>The TiC working electrode was tested as a novel, potential electrode for anodic stripping voltammetric determination of lead(II) ions traces. To demonstrate the practical applicability of the TiC electrode, an underpotential deposition/dissolution (UPD) phenomena system in electrolyte without removal of oxygen was tested. The electrode was constructed be means of mounting a TiC disk (Ø=3.5 mm) in a resin body. Three compositions of TiC were tested differing in stoichiometry, namely TiC0.6, TiC0.8, and TiC1.0. The key problem is the method of electrochemical activation of the TiC electrode. No or improperly activated electrode is not polarized and is unsuitable as a voltammetric sensor. The TiC electrode was used for the determination of Pb2+ in concentrations ranging from 1 to 100 nM. The instrumental parameters, composition of supporting electrolyte and procedures of the electrode activation were optimized. The repeatability of DP ASV runs in synthetic solutions covering the entire concentration range is better than 3%. The calibration curve is characterized by a correlation coefficient of at least 0.999. The detection limit was 2 nM for an electrodeposition time of 30 s. The method enables determination of Pb2+ in the presence of, among the others, high excesses of Cd, Cu, In, Sb, Se, and Tl ions as well as surfactants, Triton X‐100 and humic acids. The analysis of Pb2+ in synthetic solutions with and without surfactants, certified reference material and natural water samples have been performed. The voltammetric data were associated with the structural characterization of the electrode surface using scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).</description><subject>Lead</subject><subject>Mercury-free electroanalysis</subject><subject>Stripping voltammetry</subject><subject>Titanium carbide</subject><subject>Trace analysis</subject><subject>Underpotential deposition</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkE1P3DAQhiPUSqW015596i3L-CMfPq7Cdqm0pRIsIPVieZ0xdUni1A4qe-h_r1epgBunscbv8470ZNknCgsKwE6x08OCAdQgGJNH2TEtGM0FBfkmvUFADlxW77L3Mf4CAFkKeZz93bqG3Ppw74Y7surQTMG3uCA3vpt03-MUnCHNTx20mTC4ODkTiR5ashzHzhk9OT8Q6wM5w_Tfu2HeeEs2qFuyTRxGstuTq9Q0jocrz9X7D9lbq7uIH__Pk-z6y2rbnOeb7-uvzXKTGy4LmdcItoSKCzC8lai5kaApllxCxViNFm1LkeLOCt2yFqWxgovW7GpZmJozfpJ9nnvH4H8_YJxU76LBLhlD_xBVai44F3UKLuagCT7GgFaNwfU67BUFdbCsDpbVk-UEyBn44zrcv5JWq83y4iWbz2zSio9PrA73qqx4Vajbi7Wqyku6bn6s1Tf-D2ohkys</recordid><startdate>200808</startdate><enddate>200808</enddate><creator>Baś, B.</creator><creator>Piech, R.</creator><creator>Niewiara, E.</creator><creator>Ziemnicka, M.</creator><creator>Stobierski, L.</creator><creator>Kubiak, W. W.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>200808</creationdate><title>TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry</title><author>Baś, B. ; Piech, R. ; Niewiara, E. ; Ziemnicka, M. ; Stobierski, L. ; Kubiak, W. W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Lead</topic><topic>Mercury-free electroanalysis</topic><topic>Stripping voltammetry</topic><topic>Titanium carbide</topic><topic>Trace analysis</topic><topic>Underpotential deposition</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Baś, B.</creatorcontrib><creatorcontrib>Piech, R.</creatorcontrib><creatorcontrib>Niewiara, E.</creatorcontrib><creatorcontrib>Ziemnicka, M.</creatorcontrib><creatorcontrib>Stobierski, L.</creatorcontrib><creatorcontrib>Kubiak, W. W.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Baś, B.</au><au>Piech, R.</au><au>Niewiara, E.</au><au>Ziemnicka, M.</au><au>Stobierski, L.</au><au>Kubiak, W. W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2008-08</date><risdate>2008</risdate><volume>20</volume><issue>15</issue><spage>1655</spage><epage>1664</epage><pages>1655-1664</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The TiC working electrode was tested as a novel, potential electrode for anodic stripping voltammetric determination of lead(II) ions traces. To demonstrate the practical applicability of the TiC electrode, an underpotential deposition/dissolution (UPD) phenomena system in electrolyte without removal of oxygen was tested. The electrode was constructed be means of mounting a TiC disk (Ø=3.5 mm) in a resin body. Three compositions of TiC were tested differing in stoichiometry, namely TiC0.6, TiC0.8, and TiC1.0. The key problem is the method of electrochemical activation of the TiC electrode. No or improperly activated electrode is not polarized and is unsuitable as a voltammetric sensor. The TiC electrode was used for the determination of Pb2+ in concentrations ranging from 1 to 100 nM. The instrumental parameters, composition of supporting electrolyte and procedures of the electrode activation were optimized. The repeatability of DP ASV runs in synthetic solutions covering the entire concentration range is better than 3%. The calibration curve is characterized by a correlation coefficient of at least 0.999. The detection limit was 2 nM for an electrodeposition time of 30 s. The method enables determination of Pb2+ in the presence of, among the others, high excesses of Cd, Cu, In, Sb, Se, and Tl ions as well as surfactants, Triton X‐100 and humic acids. The analysis of Pb2+ in synthetic solutions with and without surfactants, certified reference material and natural water samples have been performed. The voltammetric data were associated with the structural characterization of the electrode surface using scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.200804229</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1040-0397
ispartof Electroanalysis (New York, N.Y.), 2008-08, Vol.20 (15), p.1655-1664
issn 1040-0397
1521-4109
language eng
recordid cdi_proquest_miscellaneous_34053348
source Wiley-Blackwell Read & Publish Collection
subjects Lead
Mercury-free electroanalysis
Stripping voltammetry
Titanium carbide
Trace analysis
Underpotential deposition
title TiC Working Electrode. Voltammetric Characteristics and Application for Determination of Lead Traces by Stripping Voltammetry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T05%3A22%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=TiC%20Working%20Electrode.%20Voltammetric%20Characteristics%20and%20Application%20for%20Determination%20of%20Lead%20Traces%20by%20Stripping%20Voltammetry&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Ba%C5%9B,%20B.&rft.date=2008-08&rft.volume=20&rft.issue=15&rft.spage=1655&rft.epage=1664&rft.pages=1655-1664&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.200804229&rft_dat=%3Cproquest_cross%3E34053348%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3959-8e0f607340c3d9ea3c90a1e63907228efefd1e1ebf4ad2de9cf434dcb895c8323%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=34053348&rft_id=info:pmid/&rfr_iscdi=true