A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery

A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidial-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal...

Full description

Saved in:
Bibliographic Details
Main Authors: N'Djin, W A, Melodelima, D, Schenone, F, Rivoire, M, Chapelon, J Y
Format: Conference Proceeding
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 148
container_issue
container_start_page 144
container_title
container_volume 1113
creator N'Djin, W A
Melodelima, D
Schenone, F
Rivoire, M
Chapelon, J Y
description A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidial-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4+/-3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13+/-3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8+/-0.2 cm-2) than in the other groups.
doi_str_mv 10.1063/1.3131401
format conference_proceeding
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_34361313</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34361313</sourcerecordid><originalsourceid>FETCH-LOGICAL-p186t-3ac5e29f64dfe13773cd84604d9113ef1f017cd96b8640f5e19add9bea9e06793</originalsourceid><addsrcrecordid>eNotkD9PAyEcQEnUxFo7-A2Y3K5Cfxwcbk1j_yRNXGzi1lD40WKuxwnc0G9vo05vem94hDxxNuVMwgufAgcuGL8hE60apqAWTNZM3pIRY1pUMwGf9-Qh5y_GZlqpZkTcnJaYYnDBtFU-mR4dXW-WO1qS6bIbLCbqY6Im55BL6I70hL0pwdKEGW0JsXulhtp47ls8Y1dMulyLsf218pCOmC6P5M6bNuPkn2OyW759LNbV9n21Wcy3Vc8bWSowtsaZ9lI4jxyUAusaIZlwmnNAzz3jyjotD40UzNfItXFOH9BoZFJpGJPnv26f4veAuezPIVtsW9NhHPIeBMjrIYAf4QJaIA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>34361313</pqid></control><display><type>conference_proceeding</type><title>A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>N'Djin, W A ; Melodelima, D ; Schenone, F ; Rivoire, M ; Chapelon, J Y</creator><creatorcontrib>N'Djin, W A ; Melodelima, D ; Schenone, F ; Rivoire, M ; Chapelon, J Y</creatorcontrib><description>A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidial-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4+/-3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13+/-3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8+/-0.2 cm-2) than in the other groups.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 9780735406506</identifier><identifier>ISBN: 0735406502</identifier><identifier>DOI: 10.1063/1.3131401</identifier><language>eng</language><ispartof>8th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 1113), 2009, Vol.1113, p.144-148</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>N'Djin, W A</creatorcontrib><creatorcontrib>Melodelima, D</creatorcontrib><creatorcontrib>Schenone, F</creatorcontrib><creatorcontrib>Rivoire, M</creatorcontrib><creatorcontrib>Chapelon, J Y</creatorcontrib><title>A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery</title><title>8th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 1113)</title><description>A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidial-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4+/-3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13+/-3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8+/-0.2 cm-2) than in the other groups.</description><issn>0094-243X</issn><isbn>9780735406506</isbn><isbn>0735406502</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkD9PAyEcQEnUxFo7-A2Y3K5Cfxwcbk1j_yRNXGzi1lD40WKuxwnc0G9vo05vem94hDxxNuVMwgufAgcuGL8hE60apqAWTNZM3pIRY1pUMwGf9-Qh5y_GZlqpZkTcnJaYYnDBtFU-mR4dXW-WO1qS6bIbLCbqY6Im55BL6I70hL0pwdKEGW0JsXulhtp47ls8Y1dMulyLsf218pCOmC6P5M6bNuPkn2OyW759LNbV9n21Wcy3Vc8bWSowtsaZ9lI4jxyUAusaIZlwmnNAzz3jyjotD40UzNfItXFOH9BoZFJpGJPnv26f4veAuezPIVtsW9NhHPIeBMjrIYAf4QJaIA</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>N'Djin, W A</creator><creator>Melodelima, D</creator><creator>Schenone, F</creator><creator>Rivoire, M</creator><creator>Chapelon, J Y</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20090101</creationdate><title>A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery</title><author>N'Djin, W A ; Melodelima, D ; Schenone, F ; Rivoire, M ; Chapelon, J Y</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p186t-3ac5e29f64dfe13773cd84604d9113ef1f017cd96b8640f5e19add9bea9e06793</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>N'Djin, W A</creatorcontrib><creatorcontrib>Melodelima, D</creatorcontrib><creatorcontrib>Schenone, F</creatorcontrib><creatorcontrib>Rivoire, M</creatorcontrib><creatorcontrib>Chapelon, J Y</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>N'Djin, W A</au><au>Melodelima, D</au><au>Schenone, F</au><au>Rivoire, M</au><au>Chapelon, J Y</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery</atitle><btitle>8th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 1113)</btitle><date>2009-01-01</date><risdate>2009</risdate><volume>1113</volume><spage>144</spage><epage>148</epage><pages>144-148</pages><issn>0094-243X</issn><isbn>9780735406506</isbn><isbn>0735406502</isbn><abstract>A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidial-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4+/-3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13+/-3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8+/-0.2 cm-2) than in the other groups.</abstract><doi>10.1063/1.3131401</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof 8th International Symposium on Therapeutic Ultrasound (AIP Conference Proceedings Volume 1113), 2009, Vol.1113, p.144-148
issn 0094-243X
language eng
recordid cdi_proquest_miscellaneous_34361313
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
title A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T04%3A54%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20toroidial-shaped%20HIFU%20transducer%20for%20assisting%20hepatic%20resection:%20a%20complementary%20tool%20for%20surgery&rft.btitle=8th%20International%20Symposium%20on%20Therapeutic%20Ultrasound%20(AIP%20Conference%20Proceedings%20Volume%201113)&rft.au=N'Djin,%20W%20A&rft.date=2009-01-01&rft.volume=1113&rft.spage=144&rft.epage=148&rft.pages=144-148&rft.issn=0094-243X&rft.isbn=9780735406506&rft.isbn_list=0735406502&rft_id=info:doi/10.1063/1.3131401&rft_dat=%3Cproquest%3E34361313%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p186t-3ac5e29f64dfe13773cd84604d9113ef1f017cd96b8640f5e19add9bea9e06793%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=34361313&rft_id=info:pmid/&rfr_iscdi=true