Loading…
Electrical and thermal analyses for the radio-frequency circuit of ITER NBI ion source
This paper covers specific electrical and thermal aspects of the radio-frequency (RF) circuit which supplies the ion source of the International Thermonuclear Experimental Reactor (ITER) Neutral Beam Injector (NBI). Firstly, a matching circuit for the RF Antennas is presented and a possible solution...
Saved in:
Published in: | Fusion engineering and design 2009-06, Vol.84 (7), p.2025-2030 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper covers specific electrical and thermal aspects of the radio-frequency (RF) circuit which supplies the ion source of the International Thermonuclear Experimental Reactor (ITER) Neutral Beam Injector (NBI). Firstly, a matching circuit for the RF Antennas is presented and a possible solution for the matching components discussed, in relation to the anticipated equivalent circuit parameters of the RF driven plasma. Secondly, the thermal behaviour of the RF transmission line is analyzed, utilising finite element tools, to evaluate the RF line overtemperature under the heaviest foreseen operating conditions. |
---|---|
ISSN: | 0920-3796 1873-7196 |
DOI: | 10.1016/j.fusengdes.2009.01.007 |