Loading…

Monitoring the Long-Term Performance of the Peace Tower in Ottawa

"Sensors installed at the Peace Tower [designed by John Pearson] allow for the evaluation of the long-term performance of the tower and the impact of conservation work."

Saved in:
Bibliographic Details
Published in:APT bulletin (1986) 2005-01, Vol.36 (1), p.53-59
Main Authors: Saïd, M. Nady A., Duchesne, Don, Maurenbrecher, A. H. Paul, Ibrahim, Khaled, Lumsdon, Carole, Stephenson, Doug
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 59
container_issue 1
container_start_page 53
container_title APT bulletin (1986)
container_volume 36
creator Saïd, M. Nady A.
Duchesne, Don
Maurenbrecher, A. H. Paul
Ibrahim, Khaled
Lumsdon, Carole
Stephenson, Doug
description "Sensors installed at the Peace Tower [designed by John Pearson] allow for the evaluation of the long-term performance of the tower and the impact of conservation work."
format article
fullrecord <record><control><sourceid>jstor_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_55479894</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>40003951</jstor_id><sourcerecordid>40003951</sourcerecordid><originalsourceid>FETCH-LOGICAL-j534-7b05a1e0c565e1afd4f84e1c6983914a5c41b19efb77c53514620d59e5aa2d763</originalsourceid><addsrcrecordid>eNotj8tqwzAURLVooWnaTyho1Z1BsnQtaRlCX5CSLLw3snyV2thSKjmE_n1N09UwzGHg3JAV01IXGkq4I_c5D4wJrXi1IpvPGPo5pj4c6fyFdBfDsagxTfSAycc02eCQRv83HtAupY4XTLQPdD_P9mIfyK23Y8bH_1yT-vWl3r4Xu_3bx3azKwYQslAtA8uROagAufWd9Foid5XRwnBpwUnecoO-VcqBAC6rknVgEKwtO1WJNXm-3p5S_D5jnpupzw7H0QaM59wASGW0kQv4dAWHvHg1p9RPNv00ki3OBrj4BcIqToE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>55479894</pqid></control><display><type>article</type><title>Monitoring the Long-Term Performance of the Peace Tower in Ottawa</title><source>Avery Index to Architectural Periodicals</source><source>JSTOR Archival Journals and Primary Sources Collection</source><creator>Saïd, M. Nady A. ; Duchesne, Don ; Maurenbrecher, A. H. Paul ; Ibrahim, Khaled ; Lumsdon, Carole ; Stephenson, Doug</creator><creatorcontrib>Saïd, M. Nady A. ; Duchesne, Don ; Maurenbrecher, A. H. Paul ; Ibrahim, Khaled ; Lumsdon, Carole ; Stephenson, Doug</creatorcontrib><description>"Sensors installed at the Peace Tower [designed by John Pearson] allow for the evaluation of the long-term performance of the tower and the impact of conservation work."</description><identifier>ISSN: 0848-8525</identifier><language>eng</language><publisher>Association for Preservation Technology</publisher><subject>Architectural engineering ; Concrete buildings ; Concretes ; Masonry ; Masonry buildings ; Moisture content ; Sensors ; Towers ; Wetting ; Wood buildings</subject><ispartof>APT bulletin (1986), 2005-01, Vol.36 (1), p.53-59</ispartof><rights>Copyright 2005 Association for Preservation Technology International</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/40003951$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/40003951$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>314,776,780,30982,58213,58446</link.rule.ids></links><search><creatorcontrib>Saïd, M. Nady A.</creatorcontrib><creatorcontrib>Duchesne, Don</creatorcontrib><creatorcontrib>Maurenbrecher, A. H. Paul</creatorcontrib><creatorcontrib>Ibrahim, Khaled</creatorcontrib><creatorcontrib>Lumsdon, Carole</creatorcontrib><creatorcontrib>Stephenson, Doug</creatorcontrib><title>Monitoring the Long-Term Performance of the Peace Tower in Ottawa</title><title>APT bulletin (1986)</title><description>"Sensors installed at the Peace Tower [designed by John Pearson] allow for the evaluation of the long-term performance of the tower and the impact of conservation work."</description><subject>Architectural engineering</subject><subject>Concrete buildings</subject><subject>Concretes</subject><subject>Masonry</subject><subject>Masonry buildings</subject><subject>Moisture content</subject><subject>Sensors</subject><subject>Towers</subject><subject>Wetting</subject><subject>Wood buildings</subject><issn>0848-8525</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>7QK</sourceid><recordid>eNotj8tqwzAURLVooWnaTyho1Z1BsnQtaRlCX5CSLLw3snyV2thSKjmE_n1N09UwzGHg3JAV01IXGkq4I_c5D4wJrXi1IpvPGPo5pj4c6fyFdBfDsagxTfSAycc02eCQRv83HtAupY4XTLQPdD_P9mIfyK23Y8bH_1yT-vWl3r4Xu_3bx3azKwYQslAtA8uROagAufWd9Foid5XRwnBpwUnecoO-VcqBAC6rknVgEKwtO1WJNXm-3p5S_D5jnpupzw7H0QaM59wASGW0kQv4dAWHvHg1p9RPNv00ki3OBrj4BcIqToE</recordid><startdate>20050101</startdate><enddate>20050101</enddate><creator>Saïd, M. Nady A.</creator><creator>Duchesne, Don</creator><creator>Maurenbrecher, A. H. Paul</creator><creator>Ibrahim, Khaled</creator><creator>Lumsdon, Carole</creator><creator>Stephenson, Doug</creator><general>Association for Preservation Technology</general><scope>7QK</scope><scope>FUQ</scope><scope>KCI</scope></search><sort><creationdate>20050101</creationdate><title>Monitoring the Long-Term Performance of the Peace Tower in Ottawa</title><author>Saïd, M. Nady A. ; Duchesne, Don ; Maurenbrecher, A. H. Paul ; Ibrahim, Khaled ; Lumsdon, Carole ; Stephenson, Doug</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j534-7b05a1e0c565e1afd4f84e1c6983914a5c41b19efb77c53514620d59e5aa2d763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Architectural engineering</topic><topic>Concrete buildings</topic><topic>Concretes</topic><topic>Masonry</topic><topic>Masonry buildings</topic><topic>Moisture content</topic><topic>Sensors</topic><topic>Towers</topic><topic>Wetting</topic><topic>Wood buildings</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saïd, M. Nady A.</creatorcontrib><creatorcontrib>Duchesne, Don</creatorcontrib><creatorcontrib>Maurenbrecher, A. H. Paul</creatorcontrib><creatorcontrib>Ibrahim, Khaled</creatorcontrib><creatorcontrib>Lumsdon, Carole</creatorcontrib><creatorcontrib>Stephenson, Doug</creatorcontrib><collection>Avery Index to Architectural Periodicals</collection><collection>Avery Index to Architectural Periodicals</collection><collection>Avery Index to Architectural Periodicals</collection><jtitle>APT bulletin (1986)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saïd, M. Nady A.</au><au>Duchesne, Don</au><au>Maurenbrecher, A. H. Paul</au><au>Ibrahim, Khaled</au><au>Lumsdon, Carole</au><au>Stephenson, Doug</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monitoring the Long-Term Performance of the Peace Tower in Ottawa</atitle><jtitle>APT bulletin (1986)</jtitle><date>2005-01-01</date><risdate>2005</risdate><volume>36</volume><issue>1</issue><spage>53</spage><epage>59</epage><pages>53-59</pages><issn>0848-8525</issn><abstract>"Sensors installed at the Peace Tower [designed by John Pearson] allow for the evaluation of the long-term performance of the tower and the impact of conservation work."</abstract><pub>Association for Preservation Technology</pub><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0848-8525
ispartof APT bulletin (1986), 2005-01, Vol.36 (1), p.53-59
issn 0848-8525
language eng
recordid cdi_proquest_miscellaneous_55479894
source Avery Index to Architectural Periodicals; JSTOR Archival Journals and Primary Sources Collection
subjects Architectural engineering
Concrete buildings
Concretes
Masonry
Masonry buildings
Moisture content
Sensors
Towers
Wetting
Wood buildings
title Monitoring the Long-Term Performance of the Peace Tower in Ottawa
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T06%3A58%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monitoring%20the%20Long-Term%20Performance%20of%20the%20Peace%20Tower%20in%20Ottawa&rft.jtitle=APT%20bulletin%20(1986)&rft.au=Sa%C3%AFd,%20M.%20Nady%20A.&rft.date=2005-01-01&rft.volume=36&rft.issue=1&rft.spage=53&rft.epage=59&rft.pages=53-59&rft.issn=0848-8525&rft_id=info:doi/&rft_dat=%3Cjstor_proqu%3E40003951%3C/jstor_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-j534-7b05a1e0c565e1afd4f84e1c6983914a5c41b19efb77c53514620d59e5aa2d763%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=55479894&rft_id=info:pmid/&rft_jstor_id=40003951&rfr_iscdi=true