MR imaging during endovascular procedures: An evaluation of the potential for catheter heating

MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was assessed in an...

Full description

Saved in:
Bibliographic Details
Published in:Magnetic resonance in medicine 2009-01, Vol.61 (1), p.45-53
Main Authors: Martin, Alastair J., Baek, Bryant, Acevedo-Bolton, Gabriel, Higashida, Randall T., Comstock, John, Saloner, David A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3
cites cdi_FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3
container_end_page 53
container_issue 1
container_start_page 45
container_title Magnetic resonance in medicine
container_volume 61
creator Martin, Alastair J.
Baek, Bryant
Acevedo-Bolton, Gabriel
Higashida, Randall T.
Comstock, John
Saloner, David A.
description MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was assessed in an in vitro model simulating a patient undergoing a neurovascular procedure in which MR scans of the brain will be performed. Heating adjacent to endovascular devices was assessed with fluoroptic temperature probes in a polyacrylamide gel. The effect of variable immersion lengths, lateral and longitudinal offsets, position along the endovascular device, physical MR system, and specific absorption rate (SAR) level were studied to determine their effect on catheter heating. A rapid temperature rise was evident next to endovascular devices during MR scanning and varied moderately with immersed length, position within the bore, measurement point on the device, and MR system used. Peak heating rates were less than 1°C/min with maximal SAR exposure and anatomically realistic geometries. Heating scaled linearly with SAR and SAR values below 0.2 W/kg produced negligible heating near catheters. For the evaluated application, substantial SAR restrictions, coupled with limited imaging durations, are proposed as sufficient to permit MRI without concern for thermal injury. Magn Reson Med 61:45–53, 2009. © 2008 Wiley‐Liss, Inc.
doi_str_mv 10.1002/mrm.21817
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66749595</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20372042</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3</originalsourceid><addsrcrecordid>eNqFkMtKAzEUQIMoWqsLf0CyElyMJpmkmbiTolZpFURxZ8ikN3V0HjWZ8fH3Rlt1Ja4u3Jx7CAehHUoOKCHssPLVAaMZlSuoRwVjCROKr6IekZwkKVV8A22G8EgIUUrydbRBFVGSKtlD95NrXFRmVtQzPO3854B62ryYYLvSeDz3jYX4AOEIH9cYXkzZmbZoatw43D4Anjct1G1hSuwaj62JuxY8foBI1bMttOZMGWB7Ofvo9vTkZjhKxldn58PjcWI5kzIRFjKXGq5ExjIFmZI5FypjdkqlAEcUzYlxjjBIpXBpTqnKgWSppUZwCi7to72FN_73uYPQ6qoIFsrS1NB0QQ8GMsqV-BdkJJWMcBbB_QVofROCB6fnPoby75oS_Vldx-r6q3pkd5fSLq9g-ksuM0fgcAG8FiW8_23Sk-vJtzJZXBShhbefC-Of9EDGCPru8kzfsdFokLELfZl-AGiUm0Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20372042</pqid></control><display><type>article</type><title>MR imaging during endovascular procedures: An evaluation of the potential for catheter heating</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Martin, Alastair J. ; Baek, Bryant ; Acevedo-Bolton, Gabriel ; Higashida, Randall T. ; Comstock, John ; Saloner, David A.</creator><creatorcontrib>Martin, Alastair J. ; Baek, Bryant ; Acevedo-Bolton, Gabriel ; Higashida, Randall T. ; Comstock, John ; Saloner, David A.</creatorcontrib><description>MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was assessed in an in vitro model simulating a patient undergoing a neurovascular procedure in which MR scans of the brain will be performed. Heating adjacent to endovascular devices was assessed with fluoroptic temperature probes in a polyacrylamide gel. The effect of variable immersion lengths, lateral and longitudinal offsets, position along the endovascular device, physical MR system, and specific absorption rate (SAR) level were studied to determine their effect on catheter heating. A rapid temperature rise was evident next to endovascular devices during MR scanning and varied moderately with immersed length, position within the bore, measurement point on the device, and MR system used. Peak heating rates were less than 1°C/min with maximal SAR exposure and anatomically realistic geometries. Heating scaled linearly with SAR and SAR values below 0.2 W/kg produced negligible heating near catheters. For the evaluated application, substantial SAR restrictions, coupled with limited imaging durations, are proposed as sufficient to permit MRI without concern for thermal injury. Magn Reson Med 61:45–53, 2009. © 2008 Wiley‐Liss, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>ISSN: 1522-2594</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.21817</identifier><identifier>PMID: 19097197</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Blood Vessel Prosthesis ; Blood Vessels - anatomy &amp; histology ; Blood Vessels - physiology ; Blood Vessels - radiation effects ; Body Temperature - physiology ; Body Temperature - radiation effects ; Burns - etiology ; Burns - prevention &amp; control ; Catheterization - adverse effects ; Catheterization - instrumentation ; endovascular ; Feasibility Studies ; Humans ; interventional MR ; Magnetic Resonance Imaging, Interventional - adverse effects ; Magnetic Resonance Imaging, Interventional - methods ; Models, Biological ; MR safety</subject><ispartof>Magnetic resonance in medicine, 2009-01, Vol.61 (1), p.45-53</ispartof><rights>Copyright © 2008 Wiley‐Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3</citedby><cites>FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19097197$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Martin, Alastair J.</creatorcontrib><creatorcontrib>Baek, Bryant</creatorcontrib><creatorcontrib>Acevedo-Bolton, Gabriel</creatorcontrib><creatorcontrib>Higashida, Randall T.</creatorcontrib><creatorcontrib>Comstock, John</creatorcontrib><creatorcontrib>Saloner, David A.</creatorcontrib><title>MR imaging during endovascular procedures: An evaluation of the potential for catheter heating</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was assessed in an in vitro model simulating a patient undergoing a neurovascular procedure in which MR scans of the brain will be performed. Heating adjacent to endovascular devices was assessed with fluoroptic temperature probes in a polyacrylamide gel. The effect of variable immersion lengths, lateral and longitudinal offsets, position along the endovascular device, physical MR system, and specific absorption rate (SAR) level were studied to determine their effect on catheter heating. A rapid temperature rise was evident next to endovascular devices during MR scanning and varied moderately with immersed length, position within the bore, measurement point on the device, and MR system used. Peak heating rates were less than 1°C/min with maximal SAR exposure and anatomically realistic geometries. Heating scaled linearly with SAR and SAR values below 0.2 W/kg produced negligible heating near catheters. For the evaluated application, substantial SAR restrictions, coupled with limited imaging durations, are proposed as sufficient to permit MRI without concern for thermal injury. Magn Reson Med 61:45–53, 2009. © 2008 Wiley‐Liss, Inc.</description><subject>Blood Vessel Prosthesis</subject><subject>Blood Vessels - anatomy &amp; histology</subject><subject>Blood Vessels - physiology</subject><subject>Blood Vessels - radiation effects</subject><subject>Body Temperature - physiology</subject><subject>Body Temperature - radiation effects</subject><subject>Burns - etiology</subject><subject>Burns - prevention &amp; control</subject><subject>Catheterization - adverse effects</subject><subject>Catheterization - instrumentation</subject><subject>endovascular</subject><subject>Feasibility Studies</subject><subject>Humans</subject><subject>interventional MR</subject><subject>Magnetic Resonance Imaging, Interventional - adverse effects</subject><subject>Magnetic Resonance Imaging, Interventional - methods</subject><subject>Models, Biological</subject><subject>MR safety</subject><issn>0740-3194</issn><issn>1522-2594</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqFkMtKAzEUQIMoWqsLf0CyElyMJpmkmbiTolZpFURxZ8ikN3V0HjWZ8fH3Rlt1Ja4u3Jx7CAehHUoOKCHssPLVAaMZlSuoRwVjCROKr6IekZwkKVV8A22G8EgIUUrydbRBFVGSKtlD95NrXFRmVtQzPO3854B62ryYYLvSeDz3jYX4AOEIH9cYXkzZmbZoatw43D4Anjct1G1hSuwaj62JuxY8foBI1bMttOZMGWB7Ofvo9vTkZjhKxldn58PjcWI5kzIRFjKXGq5ExjIFmZI5FypjdkqlAEcUzYlxjjBIpXBpTqnKgWSppUZwCi7to72FN_73uYPQ6qoIFsrS1NB0QQ8GMsqV-BdkJJWMcBbB_QVofROCB6fnPoby75oS_Vldx-r6q3pkd5fSLq9g-ksuM0fgcAG8FiW8_23Sk-vJtzJZXBShhbefC-Of9EDGCPru8kzfsdFokLELfZl-AGiUm0Q</recordid><startdate>200901</startdate><enddate>200901</enddate><creator>Martin, Alastair J.</creator><creator>Baek, Bryant</creator><creator>Acevedo-Bolton, Gabriel</creator><creator>Higashida, Randall T.</creator><creator>Comstock, John</creator><creator>Saloner, David A.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7TK</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>200901</creationdate><title>MR imaging during endovascular procedures: An evaluation of the potential for catheter heating</title><author>Martin, Alastair J. ; Baek, Bryant ; Acevedo-Bolton, Gabriel ; Higashida, Randall T. ; Comstock, John ; Saloner, David A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Blood Vessel Prosthesis</topic><topic>Blood Vessels - anatomy &amp; histology</topic><topic>Blood Vessels - physiology</topic><topic>Blood Vessels - radiation effects</topic><topic>Body Temperature - physiology</topic><topic>Body Temperature - radiation effects</topic><topic>Burns - etiology</topic><topic>Burns - prevention &amp; control</topic><topic>Catheterization - adverse effects</topic><topic>Catheterization - instrumentation</topic><topic>endovascular</topic><topic>Feasibility Studies</topic><topic>Humans</topic><topic>interventional MR</topic><topic>Magnetic Resonance Imaging, Interventional - adverse effects</topic><topic>Magnetic Resonance Imaging, Interventional - methods</topic><topic>Models, Biological</topic><topic>MR safety</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Martin, Alastair J.</creatorcontrib><creatorcontrib>Baek, Bryant</creatorcontrib><creatorcontrib>Acevedo-Bolton, Gabriel</creatorcontrib><creatorcontrib>Higashida, Randall T.</creatorcontrib><creatorcontrib>Comstock, John</creatorcontrib><creatorcontrib>Saloner, David A.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Martin, Alastair J.</au><au>Baek, Bryant</au><au>Acevedo-Bolton, Gabriel</au><au>Higashida, Randall T.</au><au>Comstock, John</au><au>Saloner, David A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>MR imaging during endovascular procedures: An evaluation of the potential for catheter heating</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2009-01</date><risdate>2009</risdate><volume>61</volume><issue>1</issue><spage>45</spage><epage>53</epage><pages>45-53</pages><issn>0740-3194</issn><issn>1522-2594</issn><eissn>1522-2594</eissn><abstract>MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was assessed in an in vitro model simulating a patient undergoing a neurovascular procedure in which MR scans of the brain will be performed. Heating adjacent to endovascular devices was assessed with fluoroptic temperature probes in a polyacrylamide gel. The effect of variable immersion lengths, lateral and longitudinal offsets, position along the endovascular device, physical MR system, and specific absorption rate (SAR) level were studied to determine their effect on catheter heating. A rapid temperature rise was evident next to endovascular devices during MR scanning and varied moderately with immersed length, position within the bore, measurement point on the device, and MR system used. Peak heating rates were less than 1°C/min with maximal SAR exposure and anatomically realistic geometries. Heating scaled linearly with SAR and SAR values below 0.2 W/kg produced negligible heating near catheters. For the evaluated application, substantial SAR restrictions, coupled with limited imaging durations, are proposed as sufficient to permit MRI without concern for thermal injury. Magn Reson Med 61:45–53, 2009. © 2008 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>19097197</pmid><doi>10.1002/mrm.21817</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2009-01, Vol.61 (1), p.45-53
issn 0740-3194
1522-2594
1522-2594
language eng
recordid cdi_proquest_miscellaneous_66749595
source Wiley-Blackwell Read & Publish Collection
subjects Blood Vessel Prosthesis
Blood Vessels - anatomy & histology
Blood Vessels - physiology
Blood Vessels - radiation effects
Body Temperature - physiology
Body Temperature - radiation effects
Burns - etiology
Burns - prevention & control
Catheterization - adverse effects
Catheterization - instrumentation
endovascular
Feasibility Studies
Humans
interventional MR
Magnetic Resonance Imaging, Interventional - adverse effects
Magnetic Resonance Imaging, Interventional - methods
Models, Biological
MR safety
title MR imaging during endovascular procedures: An evaluation of the potential for catheter heating
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T13%3A18%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=MR%20imaging%20during%20endovascular%20procedures:%20An%20evaluation%20of%20the%20potential%20for%20catheter%20heating&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Martin,%20Alastair%20J.&rft.date=2009-01&rft.volume=61&rft.issue=1&rft.spage=45&rft.epage=53&rft.pages=45-53&rft.issn=0740-3194&rft.eissn=1522-2594&rft_id=info:doi/10.1002/mrm.21817&rft_dat=%3Cproquest_cross%3E20372042%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4277-5ce8f3a4958289e897b45982cd175ef091b0aff02e375f3b119be083c1a541ef3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20372042&rft_id=info:pmid/19097197&rfr_iscdi=true