Loading…

Comment on "Holographic characteristics of a 1-mm-thick photopolymer to be used in holographic memories."

We believe there is an error in the calculation of the M/# in a previous paper [Appl. Opt. 42, 7008 (2003)]. From the data provided, we calculate an M/# of 3.8 rather than the reported value of 38 for the 1-mm sample tested.

Saved in:
Bibliographic Details
Published in:Applied optics (2004) 2004-07, Vol.43 (20), p.4017-4017
Main Authors: Ihas, Benjamin C, Hill, Adrian J, Schnoes, Melinda
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We believe there is an error in the calculation of the M/# in a previous paper [Appl. Opt. 42, 7008 (2003)]. From the data provided, we calculate an M/# of 3.8 rather than the reported value of 38 for the 1-mm sample tested.
ISSN:1559-128X
DOI:10.1364/AO.43.004017