Clonidine as a pre-anesthetic agent for flexible bronchoscopy
Several drugs have been employed for sedation during flexible fiberoptic bronchoscopy (FOB). Clonidine attenuates stress-induced sympathoadrenal responses and has sedative properties. We investigate the effects of clonidine pre-medication on hemodynamic and comfort parameters of patients submitted t...
Saved in:
Published in: | Respiratory medicine 2004-08, Vol.98 (8), p.746-751 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Several drugs have been employed for sedation during flexible fiberoptic bronchoscopy (FOB). Clonidine attenuates stress-induced sympathoadrenal responses and has sedative properties. We investigate the effects of clonidine pre-medication on hemodynamic and comfort parameters of patients submitted to FOB under airway topical anesthesia only. Patients received placebo (
n=22; men=16; median age=50.5 years) or intravenous clonidine (3
μg/kg;
n=20; men=15; median age=46.0 years) 15
min before FOB. Blood pressure (BP), heart rate (HR), plasma norepinephrine (nor) and cortisol levels were measured before, during, and 1
h after FOB. Comfort was assessed by the examiner and by the patients using a visual numerical scale (0–10). The placebo group showed significant increases in systolic BP, HR, and nor levels during FOB (SBP = 125
mmHg×145
mmHg; HR=74
bpm×85
bpm; nor = 316.2
pg/dl×483.1
pg/dl), whereas clonidine group did not display such changes. Clonidine group showed a lower frequency of cardiac arrhythmias than the placebo group during and after FOB (supraventricular = 39%×50%; ventricular=22%×40%). Levels of comfort were high and comparable in both groups. We concluded that although clonidine led to a somewhat better hemodynamic profile, it did not contribute to better comfort in this setting. |
---|---|