Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction

We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). Microbubbles normally pass freely through large and...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology 2004-09, Vol.44 (5), p.1036-1046
Main Authors: Tsutsui, Jeane M., Xie, Feng, Cano, Martin, Chomas, James, Phillips, Patrick, Radio, Stanley J., Lof, John, Porter, Thomas R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2004.05.056