Loading…

Evaluation of varying amounts of thermal cycling on bond strength and permanent deformation of two resilient denture liners

Two problems found in prostheses with resilient liners are bond failure to the acrylic resin base and increased permanent deformation due to material aging. This in vitro study evaluated the effect of varying amounts of thermal cycling on bond strength and permanent deformation of 2 resilient dentur...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of prosthetic dentistry 2004-09, Vol.92 (3), p.288-293
Main Authors: Ribeiro Pinto, José Renato, Mesquita, Marcelo Ferraz, de Arruda Nóbilo, Mauro Antônio, Elias Pessanha Henriques, Guilherme
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Two problems found in prostheses with resilient liners are bond failure to the acrylic resin base and increased permanent deformation due to material aging. This in vitro study evaluated the effect of varying amounts of thermal cycling on bond strength and permanent deformation of 2 resilient denture liners bonded to an acrylic resin base. Plasticized acrylic resin (PermaSoft) or silicone (Softliner) resilient lining materials were processed to a heat-polymerized acrylic resin (QC-20). One hundred rectangular specimens (10 × 10-mm 2 cross-sectional area) and 100 cylindrically-shaped specimens (12.7-mm diameter × 19.0-mm height) for each liner/resin combination were used for the tensile and deformation tests, respectively. Specimen shape and liner thickness were standardized. Specimens were divided into 9 test groups (n=10) and were thermal cycled for 200, 500, 1000, 1500, 2000, 2500, 3000, 3500, and 4000 cycles. Control specimens (n=10) were stored for 24 hours in water at 37°C. Mean bond strength, expressed as stress at failure (MPa), was determined with a tensile test using a universal testing machine at a crosshead speed of 5 mm/min. Analysis of failure mode, expressed as a percent (%), was recorded as either cohesive, adhesive, or both, after observation. Permanent deformation, expressed as a percent (%), was determined using ADA specification no. 18. Data from both tests were examined with a 2-way analysis of variance and a Tukey test (α=.05). For the tensile test, Softliner specimens submitted to different thermal cycling regimens demonstrated no significantly different bond strength values from the control; however, there was a significant difference between the PermaSoft control group (0.47 ± 0.09 MPa [mean ± SD]) and the 500 cycle group (0.46 ± 0.07 MPa) compared to the 4000 cycle group (0.70 ± 0.20 MPa) ( P
ISSN:0022-3913
1097-6841
DOI:10.1016/j.prosdent.2004.06.005