Loading…

Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction

A 75‐year‐old man was admitted to our hospital with a complaint of progressive dyspnea with effort. The patient had a permanent pacemaker that was implanted 16 years ago. Transesophageal echocardiography revealed a large, mobile mass in the right atrium attaching to the insertion site of the atrial...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 2009-02, Vol.32 (2), p.262-264
Main Authors: TUGCU, AYLIN, YILDIRIMTURK, OZLEM, TAYYARECI, YELDA, SAGBAS, ERTAN, YAZICIOGLU, NURAN, AYTEKIN, SAIDE
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3
cites cdi_FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3
container_end_page 264
container_issue 2
container_start_page 262
container_title Pacing and clinical electrophysiology
container_volume 32
creator TUGCU, AYLIN
YILDIRIMTURK, OZLEM
TAYYARECI, YELDA
SAGBAS, ERTAN
YAZICIOGLU, NURAN
AYTEKIN, SAIDE
description A 75‐year‐old man was admitted to our hospital with a complaint of progressive dyspnea with effort. The patient had a permanent pacemaker that was implanted 16 years ago. Transesophageal echocardiography revealed a large, mobile mass in the right atrium attaching to the insertion site of the atrial lead at the tricuspid valve level. Because of the size, mobility, and location of the mass, urgent surgical removal was considered. The mass was successfully removed. Histologic examination of the mass demonstrated a partially organized thrombus. The postoperative course was uneventful and the patient's symptoms improved remarkably after operation.
doi_str_mv 10.1111/j.1540-8159.2008.02211.x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66860581</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>66860581</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3</originalsourceid><addsrcrecordid>eNqNkElPwzAQhS0EomX5C8gnbgkzzuZckKqqLKISCJWz5SQTcMlS7ESFf09CK7gylxnNvPdG-hjjCD4OdbX2MQrBkxilvgCQPgiB6H8esOnv4ZBNAcPEk4FMJ-zEuTUAxBBGx2yCKSaQopyyh2fz-tbxWWeNrviTzqnW72T5knTBV2-2rbPWGcfnunemeeUra_LebUzB75uyarf8MXOd7fPOtM0ZOyp15eh830_Zy81iNb_zlo-39_PZ0svDIEQPKYtkWZLORRYllGYpCcgwIQIZDAuALM4joWWYBEWRxEUAUmBKJQoQMi2DU3a5y93Y9qMn16nauJyqSjfU9k7FsYwhkjgI5U6Y29Y5S6XaWFNr-6UQ1AhSrdXIS4281AhS_YBUn4P1Yv-jz2oq_ox7coPgeifYmoq-_h2snmbzxTgG38NXgXI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>66860581</pqid></control><display><type>article</type><title>Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction</title><source>Wiley</source><source>SPORTDiscus with Full Text</source><creator>TUGCU, AYLIN ; YILDIRIMTURK, OZLEM ; TAYYARECI, YELDA ; SAGBAS, ERTAN ; YAZICIOGLU, NURAN ; AYTEKIN, SAIDE</creator><creatorcontrib>TUGCU, AYLIN ; YILDIRIMTURK, OZLEM ; TAYYARECI, YELDA ; SAGBAS, ERTAN ; YAZICIOGLU, NURAN ; AYTEKIN, SAIDE</creatorcontrib><description>A 75‐year‐old man was admitted to our hospital with a complaint of progressive dyspnea with effort. The patient had a permanent pacemaker that was implanted 16 years ago. Transesophageal echocardiography revealed a large, mobile mass in the right atrium attaching to the insertion site of the atrial lead at the tricuspid valve level. Because of the size, mobility, and location of the mass, urgent surgical removal was considered. The mass was successfully removed. Histologic examination of the mass demonstrated a partially organized thrombus. The postoperative course was uneventful and the patient's symptoms improved remarkably after operation.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/j.1540-8159.2008.02211.x</identifier><identifier>PMID: 19170918</identifier><language>eng</language><publisher>Malden, USA: Blackwell Publishing Inc</publisher><subject>Aged ; Electrodes, Implanted - adverse effects ; Heart Atria - injuries ; Humans ; Male ; pacemaker ; Pacemaker, Artificial - adverse effects ; thrombosis ; Thrombosis - diagnosis ; Thrombosis - etiology ; Thrombosis - prevention &amp; control ; transesophageal echocardiography ; Tricuspid Valve Stenosis - diagnosis ; Tricuspid Valve Stenosis - etiology ; Tricuspid Valve Stenosis - prevention &amp; control</subject><ispartof>Pacing and clinical electrophysiology, 2009-02, Vol.32 (2), p.262-264</ispartof><rights>2009, The Authors. Journal compilation ©2009 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3</citedby><cites>FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19170918$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>TUGCU, AYLIN</creatorcontrib><creatorcontrib>YILDIRIMTURK, OZLEM</creatorcontrib><creatorcontrib>TAYYARECI, YELDA</creatorcontrib><creatorcontrib>SAGBAS, ERTAN</creatorcontrib><creatorcontrib>YAZICIOGLU, NURAN</creatorcontrib><creatorcontrib>AYTEKIN, SAIDE</creatorcontrib><title>Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>A 75‐year‐old man was admitted to our hospital with a complaint of progressive dyspnea with effort. The patient had a permanent pacemaker that was implanted 16 years ago. Transesophageal echocardiography revealed a large, mobile mass in the right atrium attaching to the insertion site of the atrial lead at the tricuspid valve level. Because of the size, mobility, and location of the mass, urgent surgical removal was considered. The mass was successfully removed. Histologic examination of the mass demonstrated a partially organized thrombus. The postoperative course was uneventful and the patient's symptoms improved remarkably after operation.</description><subject>Aged</subject><subject>Electrodes, Implanted - adverse effects</subject><subject>Heart Atria - injuries</subject><subject>Humans</subject><subject>Male</subject><subject>pacemaker</subject><subject>Pacemaker, Artificial - adverse effects</subject><subject>thrombosis</subject><subject>Thrombosis - diagnosis</subject><subject>Thrombosis - etiology</subject><subject>Thrombosis - prevention &amp; control</subject><subject>transesophageal echocardiography</subject><subject>Tricuspid Valve Stenosis - diagnosis</subject><subject>Tricuspid Valve Stenosis - etiology</subject><subject>Tricuspid Valve Stenosis - prevention &amp; control</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqNkElPwzAQhS0EomX5C8gnbgkzzuZckKqqLKISCJWz5SQTcMlS7ESFf09CK7gylxnNvPdG-hjjCD4OdbX2MQrBkxilvgCQPgiB6H8esOnv4ZBNAcPEk4FMJ-zEuTUAxBBGx2yCKSaQopyyh2fz-tbxWWeNrviTzqnW72T5knTBV2-2rbPWGcfnunemeeUra_LebUzB75uyarf8MXOd7fPOtM0ZOyp15eh830_Zy81iNb_zlo-39_PZ0svDIEQPKYtkWZLORRYllGYpCcgwIQIZDAuALM4joWWYBEWRxEUAUmBKJQoQMi2DU3a5y93Y9qMn16nauJyqSjfU9k7FsYwhkjgI5U6Y29Y5S6XaWFNr-6UQ1AhSrdXIS4281AhS_YBUn4P1Yv-jz2oq_ox7coPgeifYmoq-_h2snmbzxTgG38NXgXI</recordid><startdate>200902</startdate><enddate>200902</enddate><creator>TUGCU, AYLIN</creator><creator>YILDIRIMTURK, OZLEM</creator><creator>TAYYARECI, YELDA</creator><creator>SAGBAS, ERTAN</creator><creator>YAZICIOGLU, NURAN</creator><creator>AYTEKIN, SAIDE</creator><general>Blackwell Publishing Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200902</creationdate><title>Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction</title><author>TUGCU, AYLIN ; YILDIRIMTURK, OZLEM ; TAYYARECI, YELDA ; SAGBAS, ERTAN ; YAZICIOGLU, NURAN ; AYTEKIN, SAIDE</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged</topic><topic>Electrodes, Implanted - adverse effects</topic><topic>Heart Atria - injuries</topic><topic>Humans</topic><topic>Male</topic><topic>pacemaker</topic><topic>Pacemaker, Artificial - adverse effects</topic><topic>thrombosis</topic><topic>Thrombosis - diagnosis</topic><topic>Thrombosis - etiology</topic><topic>Thrombosis - prevention &amp; control</topic><topic>transesophageal echocardiography</topic><topic>Tricuspid Valve Stenosis - diagnosis</topic><topic>Tricuspid Valve Stenosis - etiology</topic><topic>Tricuspid Valve Stenosis - prevention &amp; control</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TUGCU, AYLIN</creatorcontrib><creatorcontrib>YILDIRIMTURK, OZLEM</creatorcontrib><creatorcontrib>TAYYARECI, YELDA</creatorcontrib><creatorcontrib>SAGBAS, ERTAN</creatorcontrib><creatorcontrib>YAZICIOGLU, NURAN</creatorcontrib><creatorcontrib>AYTEKIN, SAIDE</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TUGCU, AYLIN</au><au>YILDIRIMTURK, OZLEM</au><au>TAYYARECI, YELDA</au><au>SAGBAS, ERTAN</au><au>YAZICIOGLU, NURAN</au><au>AYTEKIN, SAIDE</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>2009-02</date><risdate>2009</risdate><volume>32</volume><issue>2</issue><spage>262</spage><epage>264</epage><pages>262-264</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>A 75‐year‐old man was admitted to our hospital with a complaint of progressive dyspnea with effort. The patient had a permanent pacemaker that was implanted 16 years ago. Transesophageal echocardiography revealed a large, mobile mass in the right atrium attaching to the insertion site of the atrial lead at the tricuspid valve level. Because of the size, mobility, and location of the mass, urgent surgical removal was considered. The mass was successfully removed. Histologic examination of the mass demonstrated a partially organized thrombus. The postoperative course was uneventful and the patient's symptoms improved remarkably after operation.</abstract><cop>Malden, USA</cop><pub>Blackwell Publishing Inc</pub><pmid>19170918</pmid><doi>10.1111/j.1540-8159.2008.02211.x</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 2009-02, Vol.32 (2), p.262-264
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_66860581
source Wiley; SPORTDiscus with Full Text
subjects Aged
Electrodes, Implanted - adverse effects
Heart Atria - injuries
Humans
Male
pacemaker
Pacemaker, Artificial - adverse effects
thrombosis
Thrombosis - diagnosis
Thrombosis - etiology
Thrombosis - prevention & control
transesophageal echocardiography
Tricuspid Valve Stenosis - diagnosis
Tricuspid Valve Stenosis - etiology
Tricuspid Valve Stenosis - prevention & control
title Right Atrial Pacemaker Lead Thrombosis Causing Tricuspid Inflow Obstruction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T22%3A22%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Right%20Atrial%20Pacemaker%20Lead%20Thrombosis%20Causing%20Tricuspid%20Inflow%20Obstruction&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=TUGCU,%20AYLIN&rft.date=2009-02&rft.volume=32&rft.issue=2&rft.spage=262&rft.epage=264&rft.pages=262-264&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/j.1540-8159.2008.02211.x&rft_dat=%3Cproquest_cross%3E66860581%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4341-1eb58ffeac2b57e9b9e20b17ee08357e00b6c52a8473dd76d308219ef120289f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=66860581&rft_id=info:pmid/19170918&rfr_iscdi=true