Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements

An all-solid-state calcium-selective electrode was constructed with poly(pyrrole) solid-contact doped with calcium complexing ligand Tiron. The potentiometric response of this sensor can have a linear range down to 10-9 M with a slope close to Nernstian and detection limit equal to 10-9.6. The effec...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2004-11, Vol.76 (21), p.6410-6418
Main Authors: Konopka, Anna, Sokalski, Tomasz, Michalska, Agata, Lewenstam, Andrzej, Maj-Zurawska, Magdalena
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3
cites cdi_FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3
container_end_page 6418
container_issue 21
container_start_page 6410
container_title Analytical chemistry (Washington)
container_volume 76
creator Konopka, Anna
Sokalski, Tomasz
Michalska, Agata
Lewenstam, Andrzej
Maj-Zurawska, Magdalena
description An all-solid-state calcium-selective electrode was constructed with poly(pyrrole) solid-contact doped with calcium complexing ligand Tiron. The potentiometric response of this sensor can have a linear range down to 10-9 M with a slope close to Nernstian and detection limit equal to 10-9.6. The effects of pH and the activity of the interfering ion in the conditioning solution on the potentiometric behavior of the constructed sensors were examined. Potential stability, reproducibility, and impedance studies were performed. The selectivity of the constructed electrode is better than that of the conventional calcium-selective electrode with internal filling solution of 10-2 M CaCl2 and comparable to that of the best liquid-contact electrodes.
doi_str_mv 10.1021/ac0492158
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67023297</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67023297</sourcerecordid><originalsourceid>FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3</originalsourceid><addsrcrecordid>eNptkc9uEzEQxi0EomnhwAsgX0DqweCx1_vnGEUtRaQiIuXCxfJ6Z2GLNw62N9DX4IlxlKi5cJkZaX7z6dM3hLwC_g64gPfG8qIRoOonZAZKcFbWtXhKZpxzyUTF-Rk5j_GecwAO5XNyBkpBCVLNyN9rY5MPkc77Hm0aNt9p-oF05RNu0uBHTGGw9AvGrd9EpL6nc-fY2ruhY-tkEtI87zKbT9zDiHv6Fsc2mA3ShXF2mEa2RrfX3iG92g_Bd0h7H-jS_2ZL3KHLJyZOAccsFF-QZ71xEV8e-wX5en11t7hhy88fPi7mS2Zk1SRWKdHJUlqQpoaGd7lWpq5q2UJb8I4bBAm2FDVXrYVCYdEVplRNUwK0fdnKC_L2oLsN_teEMelxiBady9b9FHVZcSFFU2Xw8gDa4GMM2OttGEYTHjRwvX-AfnxAZl8fRad2xO5EHhPPwJsjYKI1rs9B2SGeuFIUDTRF5tiBG2LCP497E35mY7JS-m611jfNt9tPi1Wt4aRrbNT3fgqbnN1_DP4DrNqpKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67023297</pqid></control><display><type>article</type><title>Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Konopka, Anna ; Sokalski, Tomasz ; Michalska, Agata ; Lewenstam, Andrzej ; Maj-Zurawska, Magdalena</creator><creatorcontrib>Konopka, Anna ; Sokalski, Tomasz ; Michalska, Agata ; Lewenstam, Andrzej ; Maj-Zurawska, Magdalena</creatorcontrib><description>An all-solid-state calcium-selective electrode was constructed with poly(pyrrole) solid-contact doped with calcium complexing ligand Tiron. The potentiometric response of this sensor can have a linear range down to 10-9 M with a slope close to Nernstian and detection limit equal to 10-9.6. The effects of pH and the activity of the interfering ion in the conditioning solution on the potentiometric behavior of the constructed sensors were examined. Potential stability, reproducibility, and impedance studies were performed. The selectivity of the constructed electrode is better than that of the conventional calcium-selective electrode with internal filling solution of 10-2 M CaCl2 and comparable to that of the best liquid-contact electrodes.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac0492158</identifier><identifier>PMID: 15516135</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Calcium - analysis ; Chemistry ; Electrochemical methods ; Electrodes ; Exact sciences and technology ; Potentiometry - instrumentation ; Potentiometry - methods ; Reproducibility of Results ; Sensitivity and Specificity</subject><ispartof>Analytical chemistry (Washington), 2004-11, Vol.76 (21), p.6410-6418</ispartof><rights>Copyright © 2004 American Chemical Society</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3</citedby><cites>FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16249194$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15516135$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Konopka, Anna</creatorcontrib><creatorcontrib>Sokalski, Tomasz</creatorcontrib><creatorcontrib>Michalska, Agata</creatorcontrib><creatorcontrib>Lewenstam, Andrzej</creatorcontrib><creatorcontrib>Maj-Zurawska, Magdalena</creatorcontrib><title>Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>An all-solid-state calcium-selective electrode was constructed with poly(pyrrole) solid-contact doped with calcium complexing ligand Tiron. The potentiometric response of this sensor can have a linear range down to 10-9 M with a slope close to Nernstian and detection limit equal to 10-9.6. The effects of pH and the activity of the interfering ion in the conditioning solution on the potentiometric behavior of the constructed sensors were examined. Potential stability, reproducibility, and impedance studies were performed. The selectivity of the constructed electrode is better than that of the conventional calcium-selective electrode with internal filling solution of 10-2 M CaCl2 and comparable to that of the best liquid-contact electrodes.</description><subject>Analytical chemistry</subject><subject>Calcium - analysis</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Electrodes</subject><subject>Exact sciences and technology</subject><subject>Potentiometry - instrumentation</subject><subject>Potentiometry - methods</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNptkc9uEzEQxi0EomnhwAsgX0DqweCx1_vnGEUtRaQiIuXCxfJ6Z2GLNw62N9DX4IlxlKi5cJkZaX7z6dM3hLwC_g64gPfG8qIRoOonZAZKcFbWtXhKZpxzyUTF-Rk5j_GecwAO5XNyBkpBCVLNyN9rY5MPkc77Hm0aNt9p-oF05RNu0uBHTGGw9AvGrd9EpL6nc-fY2ruhY-tkEtI87zKbT9zDiHv6Fsc2mA3ShXF2mEa2RrfX3iG92g_Bd0h7H-jS_2ZL3KHLJyZOAccsFF-QZ71xEV8e-wX5en11t7hhy88fPi7mS2Zk1SRWKdHJUlqQpoaGd7lWpq5q2UJb8I4bBAm2FDVXrYVCYdEVplRNUwK0fdnKC_L2oLsN_teEMelxiBady9b9FHVZcSFFU2Xw8gDa4GMM2OttGEYTHjRwvX-AfnxAZl8fRad2xO5EHhPPwJsjYKI1rs9B2SGeuFIUDTRF5tiBG2LCP497E35mY7JS-m611jfNt9tPi1Wt4aRrbNT3fgqbnN1_DP4DrNqpKw</recordid><startdate>20041101</startdate><enddate>20041101</enddate><creator>Konopka, Anna</creator><creator>Sokalski, Tomasz</creator><creator>Michalska, Agata</creator><creator>Lewenstam, Andrzej</creator><creator>Maj-Zurawska, Magdalena</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20041101</creationdate><title>Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements</title><author>Konopka, Anna ; Sokalski, Tomasz ; Michalska, Agata ; Lewenstam, Andrzej ; Maj-Zurawska, Magdalena</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Analytical chemistry</topic><topic>Calcium - analysis</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Electrodes</topic><topic>Exact sciences and technology</topic><topic>Potentiometry - instrumentation</topic><topic>Potentiometry - methods</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Konopka, Anna</creatorcontrib><creatorcontrib>Sokalski, Tomasz</creatorcontrib><creatorcontrib>Michalska, Agata</creatorcontrib><creatorcontrib>Lewenstam, Andrzej</creatorcontrib><creatorcontrib>Maj-Zurawska, Magdalena</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Konopka, Anna</au><au>Sokalski, Tomasz</au><au>Michalska, Agata</au><au>Lewenstam, Andrzej</au><au>Maj-Zurawska, Magdalena</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2004-11-01</date><risdate>2004</risdate><volume>76</volume><issue>21</issue><spage>6410</spage><epage>6418</epage><pages>6410-6418</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>An all-solid-state calcium-selective electrode was constructed with poly(pyrrole) solid-contact doped with calcium complexing ligand Tiron. The potentiometric response of this sensor can have a linear range down to 10-9 M with a slope close to Nernstian and detection limit equal to 10-9.6. The effects of pH and the activity of the interfering ion in the conditioning solution on the potentiometric behavior of the constructed sensors were examined. Potential stability, reproducibility, and impedance studies were performed. The selectivity of the constructed electrode is better than that of the conventional calcium-selective electrode with internal filling solution of 10-2 M CaCl2 and comparable to that of the best liquid-contact electrodes.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>15516135</pmid><doi>10.1021/ac0492158</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2004-11, Vol.76 (21), p.6410-6418
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_67023297
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Calcium - analysis
Chemistry
Electrochemical methods
Electrodes
Exact sciences and technology
Potentiometry - instrumentation
Potentiometry - methods
Reproducibility of Results
Sensitivity and Specificity
title Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T22%3A02%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Factors%20Affecting%20the%20Potentiometric%20Response%20of%20All-Solid-State%20Solvent%20Polymeric%20Membrane%20Calcium-Selective%20Electrode%20for%20Low-Level%20Measurements&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Konopka,%20Anna&rft.date=2004-11-01&rft.volume=76&rft.issue=21&rft.spage=6410&rft.epage=6418&rft.pages=6410-6418&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac0492158&rft_dat=%3Cproquest_cross%3E67023297%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a379t-752d363c13a8190da817a8783b1b40d0ae131c62805bc145e4d4a6599611bf6b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67023297&rft_id=info:pmid/15516135&rfr_iscdi=true