Loading…

Semi-closed reduction of tripod fractures of zygoma under intraoperative assessment using ultrasonography

Summary Introduction We conducted semi-closed reduction of isolated tripod fractures of the zygoma through only a brow incision under intraoperative assessment with ultrasonography. Methods Twenty-three patients with unilateral, non-comminuted tripod fractures of zygoma were selected for application...

Full description

Saved in:
Bibliographic Details
Published in:Journal of plastic, reconstructive & aesthetic surgery reconstructive & aesthetic surgery, 2009-04, Vol.62 (4), p.499-505
Main Authors: Soejima, Kazutaka, Sakurai, Hiroyuki, Nozaki, Motohiro, Kitazawa, Yoshihiko, Takeuchi, Masaki, Yamaki, Takashi, Kono, Taro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Introduction We conducted semi-closed reduction of isolated tripod fractures of the zygoma through only a brow incision under intraoperative assessment with ultrasonography. Methods Twenty-three patients with unilateral, non-comminuted tripod fractures of zygoma were selected for application of this method at Tokyo Women's Medical University and Tokyo Metropolitan Hiroo General Hospital between April 2002 and April 2006. Patients with orbital floor blowout fractures were excluded. A skin incision was made only at the lateral brow region and the reduction was performed by inserting an elevator beneath the zygomatic arch. The bone alignment was intraoperatively assessed by ultrasonography. When the reduction was accurate, the frontozygomatic suture was immobilised with a mini-plate under direct visualisation and transmaler Kirshner wire fixation was performed. The accuracy of the reduction and postoperative movement were evaluated by computed tomography (CT) scans taken at 1 and 6 months. In five cases, the DICOM (Digital Imaging and Communication in Medicine) data from the CT were analysed with 3D imaging software (V-works, CyberMed Co., Korea). Results In all cases, accurate reduction was obtained. The analysis of the 3D imaging data revealed that postoperative movement of bone fragment was minimal. Conclusions When the accurate reduction was obtained under intraoperative assessment, the semi-closed reduction and one-plate fixation with transmaler Kirshner wire is enough to treat the simple tripod fractures of zygoma. This method is minimally invasive and takes less operative time.
ISSN:1748-6815
1878-0539