Hematological changes during short-term tidal flow extracorporeal life support

Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to...

Full description

Saved in:
Bibliographic Details
Published in:Perfusion 2004-11, Vol.19 (6), p.359-363
Main Authors: Griffith, G W, Toomasian, J M, Schreiner, R J, Dusset, C M, Cook, K E, Osterholzer, K R, Merz, S I, Bartlett, R H
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3
cites cdi_FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3
container_end_page 363
container_issue 6
container_start_page 359
container_title Perfusion
container_volume 19
creator Griffith, G W
Toomasian, J M
Schreiner, R J
Dusset, C M
Cook, K E
Osterholzer, K R
Merz, S I
Bartlett, R H
description Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to achieve both venous drainage and arterialized reinfusion through a series of tubing occluders that are automated by a pump. A single venous occluder tidal flow system with a 15 Fr single-lumen cannula (n- 6) and passive filling M pump was compared to a conventional 14 Fr dual-lumen cannula (n- 7) and roller pump for four hours of VV ECLS. The changes in platelet count and plasma-free hemoglobin (pHgb) were compared. The results showed a decline in platelet counts typical of ECLS in both groups that were not significantly different from each other. A small elevation in pHgb did not rise above normal clinical levels of 15 mg/dL in either group after four hours of ECLS. Some recirculation was observed and needs to be addressed in future studies. Single occluder tidal flow ECLS may be feasible and efficacious for long-term application once recirculation is resolved and the system evaluated for long-term support.
doi_str_mv 10.1191/0267659104pf766oa
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67193151</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1191_0267659104pf766oa</sage_id><sourcerecordid>822554821</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3</originalsourceid><addsrcrecordid>eNp1kFFLwzAQx4Mobk4_gC9SfPCtM9ekSfsoQ50w9EXBt5Kml62jXWrSon57MzZQFJ-O3P3un-NHyDnQKUAO1zQRUqQ5UN4ZKYRVB2QMXMoYAF4PyXg7j7fAiJx4v6aUcs7ZMRlBKiDPRT4mj3NsVW8bu6y1aiK9Upsl-qgaXL1ZRn5lXR_36Nqor6swN419j_Cjd0pb11mHodfUBiM_dOHZn5IjoxqPZ_s6IS93t8-zebx4un-Y3SxizUTax5CVJQedZZVBSplGBqyUplRCSompyTLOE4A0MyphJpyNUIHKqMHSKMU0m5CrXW7n7NuAvi_a2mtsGrVBO_hCSMgZpBDAy1_g2g5uE24rggEukmAnQLCDtLPeOzRF5-pWuc8CaLE1XfwxHXYu9sFD2WL1vbFXG4DpDvBqiT9-_TfxC-pkiRU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>199462591</pqid></control><display><type>article</type><title>Hematological changes during short-term tidal flow extracorporeal life support</title><source>SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024: Reading List</source><creator>Griffith, G W ; Toomasian, J M ; Schreiner, R J ; Dusset, C M ; Cook, K E ; Osterholzer, K R ; Merz, S I ; Bartlett, R H</creator><creatorcontrib>Griffith, G W ; Toomasian, J M ; Schreiner, R J ; Dusset, C M ; Cook, K E ; Osterholzer, K R ; Merz, S I ; Bartlett, R H</creatorcontrib><description>Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to achieve both venous drainage and arterialized reinfusion through a series of tubing occluders that are automated by a pump. A single venous occluder tidal flow system with a 15 Fr single-lumen cannula (n- 6) and passive filling M pump was compared to a conventional 14 Fr dual-lumen cannula (n- 7) and roller pump for four hours of VV ECLS. The changes in platelet count and plasma-free hemoglobin (pHgb) were compared. The results showed a decline in platelet counts typical of ECLS in both groups that were not significantly different from each other. A small elevation in pHgb did not rise above normal clinical levels of 15 mg/dL in either group after four hours of ECLS. Some recirculation was observed and needs to be addressed in future studies. Single occluder tidal flow ECLS may be feasible and efficacious for long-term application once recirculation is resolved and the system evaluated for long-term support.</description><identifier>ISSN: 0267-6591</identifier><identifier>EISSN: 1477-111X</identifier><identifier>DOI: 10.1191/0267659104pf766oa</identifier><identifier>PMID: 15619969</identifier><language>eng</language><publisher>Thousand Oaks, CA: SAGE Publications</publisher><subject>Catheterization, Peripheral ; Extracorporeal Membrane Oxygenation - instrumentation ; Hemoglobins - analysis ; Humans ; Life Support Systems - instrumentation ; Platelet Count</subject><ispartof>Perfusion, 2004-11, Vol.19 (6), p.359-363</ispartof><rights>2004 Arnold</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3</citedby><cites>FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904,79110</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15619969$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Griffith, G W</creatorcontrib><creatorcontrib>Toomasian, J M</creatorcontrib><creatorcontrib>Schreiner, R J</creatorcontrib><creatorcontrib>Dusset, C M</creatorcontrib><creatorcontrib>Cook, K E</creatorcontrib><creatorcontrib>Osterholzer, K R</creatorcontrib><creatorcontrib>Merz, S I</creatorcontrib><creatorcontrib>Bartlett, R H</creatorcontrib><title>Hematological changes during short-term tidal flow extracorporeal life support</title><title>Perfusion</title><addtitle>Perfusion</addtitle><description>Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to achieve both venous drainage and arterialized reinfusion through a series of tubing occluders that are automated by a pump. A single venous occluder tidal flow system with a 15 Fr single-lumen cannula (n- 6) and passive filling M pump was compared to a conventional 14 Fr dual-lumen cannula (n- 7) and roller pump for four hours of VV ECLS. The changes in platelet count and plasma-free hemoglobin (pHgb) were compared. The results showed a decline in platelet counts typical of ECLS in both groups that were not significantly different from each other. A small elevation in pHgb did not rise above normal clinical levels of 15 mg/dL in either group after four hours of ECLS. Some recirculation was observed and needs to be addressed in future studies. Single occluder tidal flow ECLS may be feasible and efficacious for long-term application once recirculation is resolved and the system evaluated for long-term support.</description><subject>Catheterization, Peripheral</subject><subject>Extracorporeal Membrane Oxygenation - instrumentation</subject><subject>Hemoglobins - analysis</subject><subject>Humans</subject><subject>Life Support Systems - instrumentation</subject><subject>Platelet Count</subject><issn>0267-6591</issn><issn>1477-111X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNp1kFFLwzAQx4Mobk4_gC9SfPCtM9ekSfsoQ50w9EXBt5Kml62jXWrSon57MzZQFJ-O3P3un-NHyDnQKUAO1zQRUqQ5UN4ZKYRVB2QMXMoYAF4PyXg7j7fAiJx4v6aUcs7ZMRlBKiDPRT4mj3NsVW8bu6y1aiK9Upsl-qgaXL1ZRn5lXR_36Nqor6swN419j_Cjd0pb11mHodfUBiM_dOHZn5IjoxqPZ_s6IS93t8-zebx4un-Y3SxizUTax5CVJQedZZVBSplGBqyUplRCSompyTLOE4A0MyphJpyNUIHKqMHSKMU0m5CrXW7n7NuAvi_a2mtsGrVBO_hCSMgZpBDAy1_g2g5uE24rggEukmAnQLCDtLPeOzRF5-pWuc8CaLE1XfwxHXYu9sFD2WL1vbFXG4DpDvBqiT9-_TfxC-pkiRU</recordid><startdate>200411</startdate><enddate>200411</enddate><creator>Griffith, G W</creator><creator>Toomasian, J M</creator><creator>Schreiner, R J</creator><creator>Dusset, C M</creator><creator>Cook, K E</creator><creator>Osterholzer, K R</creator><creator>Merz, S I</creator><creator>Bartlett, R H</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7TK</scope><scope>7U7</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>200411</creationdate><title>Hematological changes during short-term tidal flow extracorporeal life support</title><author>Griffith, G W ; Toomasian, J M ; Schreiner, R J ; Dusset, C M ; Cook, K E ; Osterholzer, K R ; Merz, S I ; Bartlett, R H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Catheterization, Peripheral</topic><topic>Extracorporeal Membrane Oxygenation - instrumentation</topic><topic>Hemoglobins - analysis</topic><topic>Humans</topic><topic>Life Support Systems - instrumentation</topic><topic>Platelet Count</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Griffith, G W</creatorcontrib><creatorcontrib>Toomasian, J M</creatorcontrib><creatorcontrib>Schreiner, R J</creatorcontrib><creatorcontrib>Dusset, C M</creatorcontrib><creatorcontrib>Cook, K E</creatorcontrib><creatorcontrib>Osterholzer, K R</creatorcontrib><creatorcontrib>Merz, S I</creatorcontrib><creatorcontrib>Bartlett, R H</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Neurosciences Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Perfusion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Griffith, G W</au><au>Toomasian, J M</au><au>Schreiner, R J</au><au>Dusset, C M</au><au>Cook, K E</au><au>Osterholzer, K R</au><au>Merz, S I</au><au>Bartlett, R H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hematological changes during short-term tidal flow extracorporeal life support</atitle><jtitle>Perfusion</jtitle><addtitle>Perfusion</addtitle><date>2004-11</date><risdate>2004</risdate><volume>19</volume><issue>6</issue><spage>359</spage><epage>363</epage><pages>359-363</pages><issn>0267-6591</issn><eissn>1477-111X</eissn><abstract>Various methods exist in the clinical practice of long-term venovenous (VV) extracorporeal life support (ECLS). Among the clinical techniques used are single venous access with a dual-lumen catheter, and cannulation of the jugular and femoral veins. Tidal flow VV ECLS uses a single-lumen catheter to achieve both venous drainage and arterialized reinfusion through a series of tubing occluders that are automated by a pump. A single venous occluder tidal flow system with a 15 Fr single-lumen cannula (n- 6) and passive filling M pump was compared to a conventional 14 Fr dual-lumen cannula (n- 7) and roller pump for four hours of VV ECLS. The changes in platelet count and plasma-free hemoglobin (pHgb) were compared. The results showed a decline in platelet counts typical of ECLS in both groups that were not significantly different from each other. A small elevation in pHgb did not rise above normal clinical levels of 15 mg/dL in either group after four hours of ECLS. Some recirculation was observed and needs to be addressed in future studies. Single occluder tidal flow ECLS may be feasible and efficacious for long-term application once recirculation is resolved and the system evaluated for long-term support.</abstract><cop>Thousand Oaks, CA</cop><pub>SAGE Publications</pub><pmid>15619969</pmid><doi>10.1191/0267659104pf766oa</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0267-6591
ispartof Perfusion, 2004-11, Vol.19 (6), p.359-363
issn 0267-6591
1477-111X
language eng
recordid cdi_proquest_miscellaneous_67193151
source SAGE:Jisc Collections:SAGE Journals Read and Publish 2023-2024: Reading List
subjects Catheterization, Peripheral
Extracorporeal Membrane Oxygenation - instrumentation
Hemoglobins - analysis
Humans
Life Support Systems - instrumentation
Platelet Count
title Hematological changes during short-term tidal flow extracorporeal life support
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T12%3A17%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hematological%20changes%20during%20short-term%20tidal%20flow%20extracorporeal%20life%20support&rft.jtitle=Perfusion&rft.au=Griffith,%20G%20W&rft.date=2004-11&rft.volume=19&rft.issue=6&rft.spage=359&rft.epage=363&rft.pages=359-363&rft.issn=0267-6591&rft.eissn=1477-111X&rft_id=info:doi/10.1191/0267659104pf766oa&rft_dat=%3Cproquest_cross%3E822554821%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c365t-18bb41c88dfe003ce313b7fba6777e5f884421158fa23f004e1d1a80febfaa3c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=199462591&rft_id=info:pmid/15619969&rft_sage_id=10.1191_0267659104pf766oa&rfr_iscdi=true