Loading…

Miniature diamond anvil cell for broad range of high pressure measurements

A miniature versatile nonmagnetic diamond anvil cell for diverse physical property measurement under cryogenic environments and high magnetic fields at high pressure has been developed. Several such cells have been manufactured and tested in the Physical Properties Measurement System (PPMS) by Quant...

Full description

Saved in:
Bibliographic Details
Published in:Review of scientific instruments 2009-04, Vol.80 (4), p.043906-043906-4
Main Authors: Gavriliuk, A. G., Mironovich, A. A., Struzhkin, V. V.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833
cites cdi_FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833
container_end_page 043906-4
container_issue 4
container_start_page 043906
container_title Review of scientific instruments
container_volume 80
creator Gavriliuk, A. G.
Mironovich, A. A.
Struzhkin, V. V.
description A miniature versatile nonmagnetic diamond anvil cell for diverse physical property measurement under cryogenic environments and high magnetic fields at high pressure has been developed. Several such cells have been manufactured and tested in the Physical Properties Measurement System (PPMS) by Quantum Design at high pressures and low temperatures. The cells have good pressure stability during temperature scans down to helium temperatures and back to room temperature. The cells have been tested in strong magnetic fields and demonstrated excellent nonmagnetic properties. The wide-angle side openings give the possibility to use this cell as a "panoramic cell" in synchrotron experiments requiring large angle off-axis access. The possible experiments, which may use this cell, include spectroscopic experiments (optical, synchrotron Mössbauer, Raman, x-ray emission, etc.), different types of x-ray diffraction experiments, transport measurements (resistivity, magnetoresistivity, thermoelectromotive force, etc.), measurements of susceptibility, and many other conventional and synchrotron experiments at very low temperatures and in strong magnetic fields.
doi_str_mv 10.1063/1.3122051
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67194523</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67194523</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833</originalsourceid><addsrcrecordid>eNp1kM1KxDAURoMozji68AUkK8FFxyQ3aZuNIIO_jLjRdUibdCbSNmPSCr69LVN05d18XHLykRyEzilZUpLCNV0CZYwIeoDmlOQyyVIGh2hOCPAkzXg-QycxfpBhBKXHaEYlJ2I4mKPnF9c63fXBYuN041uDdfvlalzausaVD7gIXhscdLux2Fd46zZbvAs2xvFOY_WYjW27eIqOKl1HezblAr3f372tHpP168PT6nadlAB5lxhggoqislxqYJAWxvACiOAwrAWThJVSVjIHw2kmdAFVqimTrCR5xngOsECX-95d8J-9jZ1qXByfq1vr-6jSbPieYCN4tQfL4GMMtlK74BodvhUlahSnqJrEDezFVNoXjTV_5GRqAG72QCxdpzvn2__bfp2qyanSLfwAnmB8Iw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67194523</pqid></control><display><type>article</type><title>Miniature diamond anvil cell for broad range of high pressure measurements</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><source>American Institute of Physics</source><creator>Gavriliuk, A. G. ; Mironovich, A. A. ; Struzhkin, V. V.</creator><creatorcontrib>Gavriliuk, A. G. ; Mironovich, A. A. ; Struzhkin, V. V.</creatorcontrib><description>A miniature versatile nonmagnetic diamond anvil cell for diverse physical property measurement under cryogenic environments and high magnetic fields at high pressure has been developed. Several such cells have been manufactured and tested in the Physical Properties Measurement System (PPMS) by Quantum Design at high pressures and low temperatures. The cells have good pressure stability during temperature scans down to helium temperatures and back to room temperature. The cells have been tested in strong magnetic fields and demonstrated excellent nonmagnetic properties. The wide-angle side openings give the possibility to use this cell as a "panoramic cell" in synchrotron experiments requiring large angle off-axis access. The possible experiments, which may use this cell, include spectroscopic experiments (optical, synchrotron Mössbauer, Raman, x-ray emission, etc.), different types of x-ray diffraction experiments, transport measurements (resistivity, magnetoresistivity, thermoelectromotive force, etc.), measurements of susceptibility, and many other conventional and synchrotron experiments at very low temperatures and in strong magnetic fields.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.3122051</identifier><identifier>PMID: 19405674</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><ispartof>Review of scientific instruments, 2009-04, Vol.80 (4), p.043906-043906-4</ispartof><rights>2009 American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833</citedby><cites>FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.3122051$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,778,780,791,27901,27902,76352</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19405674$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gavriliuk, A. G.</creatorcontrib><creatorcontrib>Mironovich, A. A.</creatorcontrib><creatorcontrib>Struzhkin, V. V.</creatorcontrib><title>Miniature diamond anvil cell for broad range of high pressure measurements</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>A miniature versatile nonmagnetic diamond anvil cell for diverse physical property measurement under cryogenic environments and high magnetic fields at high pressure has been developed. Several such cells have been manufactured and tested in the Physical Properties Measurement System (PPMS) by Quantum Design at high pressures and low temperatures. The cells have good pressure stability during temperature scans down to helium temperatures and back to room temperature. The cells have been tested in strong magnetic fields and demonstrated excellent nonmagnetic properties. The wide-angle side openings give the possibility to use this cell as a "panoramic cell" in synchrotron experiments requiring large angle off-axis access. The possible experiments, which may use this cell, include spectroscopic experiments (optical, synchrotron Mössbauer, Raman, x-ray emission, etc.), different types of x-ray diffraction experiments, transport measurements (resistivity, magnetoresistivity, thermoelectromotive force, etc.), measurements of susceptibility, and many other conventional and synchrotron experiments at very low temperatures and in strong magnetic fields.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp1kM1KxDAURoMozji68AUkK8FFxyQ3aZuNIIO_jLjRdUibdCbSNmPSCr69LVN05d18XHLykRyEzilZUpLCNV0CZYwIeoDmlOQyyVIGh2hOCPAkzXg-QycxfpBhBKXHaEYlJ2I4mKPnF9c63fXBYuN041uDdfvlalzausaVD7gIXhscdLux2Fd46zZbvAs2xvFOY_WYjW27eIqOKl1HezblAr3f372tHpP168PT6nadlAB5lxhggoqislxqYJAWxvACiOAwrAWThJVSVjIHw2kmdAFVqimTrCR5xngOsECX-95d8J-9jZ1qXByfq1vr-6jSbPieYCN4tQfL4GMMtlK74BodvhUlahSnqJrEDezFVNoXjTV_5GRqAG72QCxdpzvn2__bfp2qyanSLfwAnmB8Iw</recordid><startdate>20090401</startdate><enddate>20090401</enddate><creator>Gavriliuk, A. G.</creator><creator>Mironovich, A. A.</creator><creator>Struzhkin, V. V.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20090401</creationdate><title>Miniature diamond anvil cell for broad range of high pressure measurements</title><author>Gavriliuk, A. G. ; Mironovich, A. A. ; Struzhkin, V. V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gavriliuk, A. G.</creatorcontrib><creatorcontrib>Mironovich, A. A.</creatorcontrib><creatorcontrib>Struzhkin, V. V.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gavriliuk, A. G.</au><au>Mironovich, A. A.</au><au>Struzhkin, V. V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Miniature diamond anvil cell for broad range of high pressure measurements</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2009-04-01</date><risdate>2009</risdate><volume>80</volume><issue>4</issue><spage>043906</spage><epage>043906-4</epage><pages>043906-043906-4</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>A miniature versatile nonmagnetic diamond anvil cell for diverse physical property measurement under cryogenic environments and high magnetic fields at high pressure has been developed. Several such cells have been manufactured and tested in the Physical Properties Measurement System (PPMS) by Quantum Design at high pressures and low temperatures. The cells have good pressure stability during temperature scans down to helium temperatures and back to room temperature. The cells have been tested in strong magnetic fields and demonstrated excellent nonmagnetic properties. The wide-angle side openings give the possibility to use this cell as a "panoramic cell" in synchrotron experiments requiring large angle off-axis access. The possible experiments, which may use this cell, include spectroscopic experiments (optical, synchrotron Mössbauer, Raman, x-ray emission, etc.), different types of x-ray diffraction experiments, transport measurements (resistivity, magnetoresistivity, thermoelectromotive force, etc.), measurements of susceptibility, and many other conventional and synchrotron experiments at very low temperatures and in strong magnetic fields.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>19405674</pmid><doi>10.1063/1.3122051</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2009-04, Vol.80 (4), p.043906-043906-4
issn 0034-6748
1089-7623
language eng
recordid cdi_proquest_miscellaneous_67194523
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list); American Institute of Physics
title Miniature diamond anvil cell for broad range of high pressure measurements
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-23T23%3A04%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Miniature%20diamond%20anvil%20cell%20for%20broad%20range%20of%20high%20pressure%20measurements&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Gavriliuk,%20A.%20G.&rft.date=2009-04-01&rft.volume=80&rft.issue=4&rft.spage=043906&rft.epage=043906-4&rft.pages=043906-043906-4&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.3122051&rft_dat=%3Cproquest_cross%3E67194523%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c338t-d32515bfe49a3236bdd4b30543a32b2902c99f983d4175ab3f6a1292c08724833%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67194523&rft_id=info:pmid/19405674&rfr_iscdi=true