Loading…

Perforation of the Third Extensor Compartment by the Drill Bit During Palmar Plating of the Distal Radius

The frequency of penetration into the third extensor compartment when drilling the distal screw holes was assessed for four different palmar distal radius plates in 160 cadaver forearms. Penetration into this compartment occurred in 43%. Different plates had different penetration rates: 3.5 LCP four...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of hand surgery, European volume European volume, 2009-06, Vol.34 (3), p.333-335
Main Authors: PICHLER, W., GRECHENIG, W., CLEMENT, H., WINDISCH, G., TESCH, N. P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The frequency of penetration into the third extensor compartment when drilling the distal screw holes was assessed for four different palmar distal radius plates in 160 cadaver forearms. Penetration into this compartment occurred in 43%. Different plates had different penetration rates: 3.5 LCP four-hole locking T-plate: 20%, 3.5 LCP three-hole locking plate: 42.5%, 2.4 palmar LCP standard plate and the 2.4 palmar LCP buttress plate: 55%. When using a palmar plate on the distal radius, the surgeon risks penetrating into the third extensor compartment.