Loading…

Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography

Assessment of tricuspid valve (TV) function plays an important role in a number of clinical disease states, including left-sided valve disease and heart failure. However, the TV is a complex structure that, unlike the aortic and mitral valve, it is not possible to visualize in one cross-sectional vi...

Full description

Saved in:
Bibliographic Details
Published in:European journal of echocardiography 2009-06, Vol.10 (4), p.477-484
Main Authors: Badano, Luigi P., Agricola, Eustachio, de Isla, Leopoldo Perez, Gianfagna, Pasquale, Zamorano, Jose Louis
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93
cites cdi_FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93
container_end_page 484
container_issue 4
container_start_page 477
container_title European journal of echocardiography
container_volume 10
creator Badano, Luigi P.
Agricola, Eustachio
de Isla, Leopoldo Perez
Gianfagna, Pasquale
Zamorano, Jose Louis
description Assessment of tricuspid valve (TV) function plays an important role in a number of clinical disease states, including left-sided valve disease and heart failure. However, the TV is a complex structure that, unlike the aortic and mitral valve, it is not possible to visualize in one cross-sectional view using either transthoracic or transoesophageal two-dimensional echocardiography (i.e. imaging all three TV leaflets and their attachment in the annulus simultaneously). Conversely, three-dimensional echocardiography allows users to visualize the whole TV apparatus from any perspective. This may significantly improve our understanding of the pathophysiological mechanisms underlying the various TV diseases and functional tricuspid regurgitation, and potentially suggest ways to improve surgical treatment. This review details the current status of real-time three-dimensional echocardiography evaluation of TV morphology and function with its clinical applications and limitations.
doi_str_mv 10.1093/ejechocard/jep044
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67312141</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/ejechocard/jep044</oup_id><sourcerecordid>67312141</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93</originalsourceid><addsrcrecordid>eNqNkEtPwzAQhC0EoqXwA7ggnzgR6lea-oiq8pAqcYFzZDvrJlUSBzsp6r_HpUW9ctqR9pvR7iB0S8kjJZJPYQOmdEb5YrqBjghxhsY05SxhlIrzvWZp1LNshK5C2BBC41ZcohGVYs7kjI_R93Kr6kH1lWuxs7gvAfe-MkPoqgLH1RZw43xXutqtd1i1BbZDa35xvYuoakNfOq9MZbAHVSd91cSI0gMkRZRtiKiq8d-hlVt71ZW7a3RhVR3g5jgn6PN5-bF4TVbvL2-Lp1VieCb7hFvGJdEFkcqSlFg1Z9zMQWRcaBYf5mmmDQewIEFIqaUmqQCjC8aZ1UbyCbo_5HbefQ0Q-rypgoG6Vi24IeSzjFNGBY0gPYDGuxA82LzzVaP8Lqck37edn9rOD21Hz90xfNANFCfHsd4IPBwAN3T_yPsBqAOR8g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67312141</pqid></control><display><type>article</type><title>Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography</title><source>Oxford Journals Online</source><creator>Badano, Luigi P. ; Agricola, Eustachio ; de Isla, Leopoldo Perez ; Gianfagna, Pasquale ; Zamorano, Jose Louis</creator><creatorcontrib>Badano, Luigi P. ; Agricola, Eustachio ; de Isla, Leopoldo Perez ; Gianfagna, Pasquale ; Zamorano, Jose Louis</creatorcontrib><description>Assessment of tricuspid valve (TV) function plays an important role in a number of clinical disease states, including left-sided valve disease and heart failure. However, the TV is a complex structure that, unlike the aortic and mitral valve, it is not possible to visualize in one cross-sectional view using either transthoracic or transoesophageal two-dimensional echocardiography (i.e. imaging all three TV leaflets and their attachment in the annulus simultaneously). Conversely, three-dimensional echocardiography allows users to visualize the whole TV apparatus from any perspective. This may significantly improve our understanding of the pathophysiological mechanisms underlying the various TV diseases and functional tricuspid regurgitation, and potentially suggest ways to improve surgical treatment. This review details the current status of real-time three-dimensional echocardiography evaluation of TV morphology and function with its clinical applications and limitations.</description><identifier>ISSN: 1525-2167</identifier><identifier>EISSN: 1532-2114</identifier><identifier>DOI: 10.1093/ejechocard/jep044</identifier><identifier>PMID: 19482963</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Echocardiography, Three-Dimensional - methods ; Heart Valve Diseases - diagnostic imaging ; Heart Valve Diseases - pathology ; Heart Valve Diseases - physiopathology ; Humans ; Sensitivity and Specificity ; Tricuspid Valve - anatomy &amp; histology ; Tricuspid Valve - diagnostic imaging ; Tricuspid Valve - physiopathology</subject><ispartof>European journal of echocardiography, 2009-06, Vol.10 (4), p.477-484</ispartof><rights>Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2009. For permissions please email: journals.permissions@oxfordjournals.org 2009</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93</citedby><cites>FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19482963$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Badano, Luigi P.</creatorcontrib><creatorcontrib>Agricola, Eustachio</creatorcontrib><creatorcontrib>de Isla, Leopoldo Perez</creatorcontrib><creatorcontrib>Gianfagna, Pasquale</creatorcontrib><creatorcontrib>Zamorano, Jose Louis</creatorcontrib><title>Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography</title><title>European journal of echocardiography</title><addtitle>Eur J Echocardiogr</addtitle><description>Assessment of tricuspid valve (TV) function plays an important role in a number of clinical disease states, including left-sided valve disease and heart failure. However, the TV is a complex structure that, unlike the aortic and mitral valve, it is not possible to visualize in one cross-sectional view using either transthoracic or transoesophageal two-dimensional echocardiography (i.e. imaging all three TV leaflets and their attachment in the annulus simultaneously). Conversely, three-dimensional echocardiography allows users to visualize the whole TV apparatus from any perspective. This may significantly improve our understanding of the pathophysiological mechanisms underlying the various TV diseases and functional tricuspid regurgitation, and potentially suggest ways to improve surgical treatment. This review details the current status of real-time three-dimensional echocardiography evaluation of TV morphology and function with its clinical applications and limitations.</description><subject>Echocardiography, Three-Dimensional - methods</subject><subject>Heart Valve Diseases - diagnostic imaging</subject><subject>Heart Valve Diseases - pathology</subject><subject>Heart Valve Diseases - physiopathology</subject><subject>Humans</subject><subject>Sensitivity and Specificity</subject><subject>Tricuspid Valve - anatomy &amp; histology</subject><subject>Tricuspid Valve - diagnostic imaging</subject><subject>Tricuspid Valve - physiopathology</subject><issn>1525-2167</issn><issn>1532-2114</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqNkEtPwzAQhC0EoqXwA7ggnzgR6lea-oiq8pAqcYFzZDvrJlUSBzsp6r_HpUW9ctqR9pvR7iB0S8kjJZJPYQOmdEb5YrqBjghxhsY05SxhlIrzvWZp1LNshK5C2BBC41ZcohGVYs7kjI_R93Kr6kH1lWuxs7gvAfe-MkPoqgLH1RZw43xXutqtd1i1BbZDa35xvYuoakNfOq9MZbAHVSd91cSI0gMkRZRtiKiq8d-hlVt71ZW7a3RhVR3g5jgn6PN5-bF4TVbvL2-Lp1VieCb7hFvGJdEFkcqSlFg1Z9zMQWRcaBYf5mmmDQewIEFIqaUmqQCjC8aZ1UbyCbo_5HbefQ0Q-rypgoG6Vi24IeSzjFNGBY0gPYDGuxA82LzzVaP8Lqck37edn9rOD21Hz90xfNANFCfHsd4IPBwAN3T_yPsBqAOR8g</recordid><startdate>200906</startdate><enddate>200906</enddate><creator>Badano, Luigi P.</creator><creator>Agricola, Eustachio</creator><creator>de Isla, Leopoldo Perez</creator><creator>Gianfagna, Pasquale</creator><creator>Zamorano, Jose Louis</creator><general>Oxford University Press</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200906</creationdate><title>Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography</title><author>Badano, Luigi P. ; Agricola, Eustachio ; de Isla, Leopoldo Perez ; Gianfagna, Pasquale ; Zamorano, Jose Louis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Echocardiography, Three-Dimensional - methods</topic><topic>Heart Valve Diseases - diagnostic imaging</topic><topic>Heart Valve Diseases - pathology</topic><topic>Heart Valve Diseases - physiopathology</topic><topic>Humans</topic><topic>Sensitivity and Specificity</topic><topic>Tricuspid Valve - anatomy &amp; histology</topic><topic>Tricuspid Valve - diagnostic imaging</topic><topic>Tricuspid Valve - physiopathology</topic><toplevel>online_resources</toplevel><creatorcontrib>Badano, Luigi P.</creatorcontrib><creatorcontrib>Agricola, Eustachio</creatorcontrib><creatorcontrib>de Isla, Leopoldo Perez</creatorcontrib><creatorcontrib>Gianfagna, Pasquale</creatorcontrib><creatorcontrib>Zamorano, Jose Louis</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of echocardiography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Badano, Luigi P.</au><au>Agricola, Eustachio</au><au>de Isla, Leopoldo Perez</au><au>Gianfagna, Pasquale</au><au>Zamorano, Jose Louis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography</atitle><jtitle>European journal of echocardiography</jtitle><addtitle>Eur J Echocardiogr</addtitle><date>2009-06</date><risdate>2009</risdate><volume>10</volume><issue>4</issue><spage>477</spage><epage>484</epage><pages>477-484</pages><issn>1525-2167</issn><eissn>1532-2114</eissn><abstract>Assessment of tricuspid valve (TV) function plays an important role in a number of clinical disease states, including left-sided valve disease and heart failure. However, the TV is a complex structure that, unlike the aortic and mitral valve, it is not possible to visualize in one cross-sectional view using either transthoracic or transoesophageal two-dimensional echocardiography (i.e. imaging all three TV leaflets and their attachment in the annulus simultaneously). Conversely, three-dimensional echocardiography allows users to visualize the whole TV apparatus from any perspective. This may significantly improve our understanding of the pathophysiological mechanisms underlying the various TV diseases and functional tricuspid regurgitation, and potentially suggest ways to improve surgical treatment. This review details the current status of real-time three-dimensional echocardiography evaluation of TV morphology and function with its clinical applications and limitations.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>19482963</pmid><doi>10.1093/ejechocard/jep044</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1525-2167
ispartof European journal of echocardiography, 2009-06, Vol.10 (4), p.477-484
issn 1525-2167
1532-2114
language eng
recordid cdi_proquest_miscellaneous_67312141
source Oxford Journals Online
subjects Echocardiography, Three-Dimensional - methods
Heart Valve Diseases - diagnostic imaging
Heart Valve Diseases - pathology
Heart Valve Diseases - physiopathology
Humans
Sensitivity and Specificity
Tricuspid Valve - anatomy & histology
Tricuspid Valve - diagnostic imaging
Tricuspid Valve - physiopathology
title Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T20%3A29%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20tricuspid%20valve%20morphology%20and%20function%20by%20transthoracic%20real-time%20three-dimensional%20echocardiography&rft.jtitle=European%20journal%20of%20echocardiography&rft.au=Badano,%20Luigi%20P.&rft.date=2009-06&rft.volume=10&rft.issue=4&rft.spage=477&rft.epage=484&rft.pages=477-484&rft.issn=1525-2167&rft.eissn=1532-2114&rft_id=info:doi/10.1093/ejechocard/jep044&rft_dat=%3Cproquest_cross%3E67312141%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c379t-3f2390bd09af050fa823c8e4734b2044357bc3eefe9e499b9b054ecbd232fbc93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67312141&rft_id=info:pmid/19482963&rft_oup_id=10.1093/ejechocard/jep044&rfr_iscdi=true