Initial experience with antibiotic-impregnated silicone catheters for shunting of cerebrospinal fluid in children
Infection is a major complication of cerebrospinal fluid (CSF) shunting procedures. Recently, rifampin-impregnated and clindamycin-impregnated silicone catheters have been developed in an attempt to prevent and/or reduce the incidence of shunt infections. In vitro and in vivo animal studies have sho...
Saved in:
Published in: | Child's nervous system 2005-01, Vol.21 (1), p.56-61 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Infection is a major complication of cerebrospinal fluid (CSF) shunting procedures. Recently, rifampin-impregnated and clindamycin-impregnated silicone catheters have been developed in an attempt to prevent and/or reduce the incidence of shunt infections. In vitro and in vivo animal studies have shown their efficacy in reducing bacterial colonization of catheters. However, these shunts are yet to be evaluated in clinical trials and their safety and efficacy in preventing shunt infections is unknown.
Between April 2002 and April 2003, 31 children (age range 6 months to 17 years, mean 4.5 years) underwent implantation of an antibiotic-impregnated silicone catheter for CSF diversion. All surgeries were performed by a single neurosurgeon (HSM) at a single medical center. The Codman Hakim Bactiseal silicone catheter was used in all children. Thirty-two catheters were implanted in 31 children. All children have been followed since surgery (for an average of 19 months). For comparison, the previous 46 standard implanted shunts over a similar period of time were reviewed (average follow-up 31 months).
Of the 32 implanted catheters, 11 involved placement of a new complete shunt system, 8 were distal revisions, and 13 were proximal/ventricular revisions. There were fewer early and late complications than in the standard shunt group (12.5 and 18.8% vs. 23.9 and 34.8%). There was no local reaction from implantation of the catheters. One child contaminated his distal catheter by disrupting his abdominal incision. None of the other patients have developed any evidence of shunt infection to date.
Rifampin-impregnated and clindamycin-impregnated silicone catheters appear to be safe and well tolerated in children. Preliminary results suggest a low incidence of shunt infection. Longer follow-up and a larger number of patients are needed to more accurately assess the efficacy of these catheters compared with traditional silicone catheters. |
---|---|
ISSN: | 0256-7040 1433-0350 |
DOI: | 10.1007/s00381-004-1052-x |