Loading…

Center Effect on Ankle–Brachial Index Measurement When Using the Reference Method (Doppler and Manometer): Results From a Large Cohort Study

Background The ankle–brachial index (ABI) is a simple and noninvasive tool used to detect peripheral arterial disease (PAD). We aimed to assess, in a French multicenter cohort, the center effect associated with arterial pressure (AP) and ABI measurements using the reference method and using a semiau...

Full description

Saved in:
Bibliographic Details
Published in:American journal of hypertension 2009-07, Vol.22 (7), p.718-722
Main Authors: Vierron, Emilie, Halimi, Jean-Michel, Tichet, Jean, Balkau, Beverley, Cogneau, Joel, Giraudeau, Bruno
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background The ankle–brachial index (ABI) is a simple and noninvasive tool used to detect peripheral arterial disease (PAD). We aimed to assess, in a French multicenter cohort, the center effect associated with arterial pressure (AP) and ABI measurements using the reference method and using a semiautomatic device. Methods This study included baseline and 9-year follow-up data from 3,664 volunteers of 10 health examination centers of the DESIR (Data from an Epidemiological Study on the Insulin Resistance) syndrome French cohort. Ankle and brachial AP were measured at inclusion by the reference method (a mercury sphygmomanometer coupled with a Doppler probe for ankle measurements) and at 9 years by a semiautomatic device (Omron HEM-705CP). The center effect was assessed by the intraclass correlation coefficient (ICC), ratio of the between-center variance to the total variance of the measurement. Results At inclusion, the sample mean age was 47.5 (s.d. 9.9) years; 49.3% were men. Although ICCs were smaller than 0.05 for brachial AP measurements, they were close to 0.18 and 0.20 for ankle systolic AP (SAP) and ABI measurements, respectively, when the reference method was used. No center effect for measures other than ankle SAP was detected. With the semiautomatic device method, all ICCs, including those for ankle SAP and ABI measurements, were between 0.005 and 0.04. Conclusions We found an important center effect on ABI measured with a sphygmomanometer and a Doppler probe but not a semiautomatic device. A center effect should be taken into account when planning any multicenter study on ABI measurement.
ISSN:0895-7061
1941-7225
1879-1905
DOI:10.1038/ajh.2009.78