Loading…
Independent component analysis for biomedical signals
Independent component analysis (ICA) is increasing in popularity in the field of biomedical signal processing. It is generally used when it is required to separate measured multi-channel biomedical signals into their constituent underlying components. The use of ICA has been facilitated in part by t...
Saved in:
Published in: | Physiological measurement 2005-02, Vol.26 (1), p.R15-R39 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53 |
---|---|
cites | cdi_FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53 |
container_end_page | R39 |
container_issue | 1 |
container_start_page | R15 |
container_title | Physiological measurement |
container_volume | 26 |
creator | James, Christopher J Hesse, Christian W |
description | Independent component analysis (ICA) is increasing in popularity in the field of biomedical signal processing. It is generally used when it is required to separate measured multi-channel biomedical signals into their constituent underlying components. The use of ICA has been facilitated in part by the free availability of toolboxes that implement popular flavours of the techniques. Fundamentally ICA in biomedicine involves the extraction and separation of statistically independent sources underlying multiple measurements of biomedical signals. Technical advances in algorithmic developments implementing ICA are reviewed along with new directions in the field. These advances are specifically summarized with applications to biomedical signals in mind. The basic assumptions that are made when applying ICA are discussed, along with their implications when applied particularly to biomedical signals. ICA as a specific embodiment of blind source separation (BSS) is also discussed, and as a consequence the criterion used for establishing independence between sources is reviewed and this leads to the introduction of ICA/BSS techniques based on time, frequency and joint time-frequency decomposition of the data. Finally, advanced implementations of ICA are illustrated as applied to neurophysiologic signals in the form of electro-magnetic brain signals data. |
doi_str_mv | 10.1088/0967-3334/26/1/R02 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_67481268</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17338752</sourcerecordid><originalsourceid>FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53</originalsourceid><addsrcrecordid>eNqFkE1Lw0AQhhdRbK3-AQ-Sk-AhZmf2M0cpfhQKguh52SYbiSTZmG0P_fduaKmHgl5mBuaZd-Ah5BroPVCtM5pLlTLGeIYyg-yN4gmZApOQSqHyUzI9ABNyEcIXpQAaxTmZgFActWJTIhZd6XoXS7dOCt_2vhsn29lmG-qQVH5IVrVvXVkXtklC_Rk34ZKcVbG5q32fkY-nx_f5S7p8fV7MH5ZpwQVbpwydpg6tLpwCFDKvQOWalsgLRhFygY6B4Nw6oGWuXE4tIlecYpnTygo2I7e73H7w3xsX1qatQ-GaxnbOb4KRimtAqf8FQTGmlcAI4g4sBh_C4CrTD3Vrh60BakarZpRmRmkGpQETrcajm336ZhVN_J7sNUbgbgfUvj9sj4NMX1aRTY_ZP57_AFYBiyM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17338752</pqid></control><display><type>article</type><title>Independent component analysis for biomedical signals</title><source>Institute of Physics</source><creator>James, Christopher J ; Hesse, Christian W</creator><creatorcontrib>James, Christopher J ; Hesse, Christian W</creatorcontrib><description>Independent component analysis (ICA) is increasing in popularity in the field of biomedical signal processing. It is generally used when it is required to separate measured multi-channel biomedical signals into their constituent underlying components. The use of ICA has been facilitated in part by the free availability of toolboxes that implement popular flavours of the techniques. Fundamentally ICA in biomedicine involves the extraction and separation of statistically independent sources underlying multiple measurements of biomedical signals. Technical advances in algorithmic developments implementing ICA are reviewed along with new directions in the field. These advances are specifically summarized with applications to biomedical signals in mind. The basic assumptions that are made when applying ICA are discussed, along with their implications when applied particularly to biomedical signals. ICA as a specific embodiment of blind source separation (BSS) is also discussed, and as a consequence the criterion used for establishing independence between sources is reviewed and this leads to the introduction of ICA/BSS techniques based on time, frequency and joint time-frequency decomposition of the data. Finally, advanced implementations of ICA are illustrated as applied to neurophysiologic signals in the form of electro-magnetic brain signals data.</description><identifier>ISSN: 0967-3334</identifier><identifier>EISSN: 1361-6579</identifier><identifier>DOI: 10.1088/0967-3334/26/1/R02</identifier><identifier>PMID: 15742873</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Biomedical Technology - trends ; Brain - physiology ; Electroencephalography ; Electromagnetic Fields ; Electronics ; Equipment Design ; Humans ; Signal Processing, Computer-Assisted</subject><ispartof>Physiological measurement, 2005-02, Vol.26 (1), p.R15-R39</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53</citedby><cites>FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15742873$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>James, Christopher J</creatorcontrib><creatorcontrib>Hesse, Christian W</creatorcontrib><title>Independent component analysis for biomedical signals</title><title>Physiological measurement</title><addtitle>Physiol Meas</addtitle><description>Independent component analysis (ICA) is increasing in popularity in the field of biomedical signal processing. It is generally used when it is required to separate measured multi-channel biomedical signals into their constituent underlying components. The use of ICA has been facilitated in part by the free availability of toolboxes that implement popular flavours of the techniques. Fundamentally ICA in biomedicine involves the extraction and separation of statistically independent sources underlying multiple measurements of biomedical signals. Technical advances in algorithmic developments implementing ICA are reviewed along with new directions in the field. These advances are specifically summarized with applications to biomedical signals in mind. The basic assumptions that are made when applying ICA are discussed, along with their implications when applied particularly to biomedical signals. ICA as a specific embodiment of blind source separation (BSS) is also discussed, and as a consequence the criterion used for establishing independence between sources is reviewed and this leads to the introduction of ICA/BSS techniques based on time, frequency and joint time-frequency decomposition of the data. Finally, advanced implementations of ICA are illustrated as applied to neurophysiologic signals in the form of electro-magnetic brain signals data.</description><subject>Biomedical Technology - trends</subject><subject>Brain - physiology</subject><subject>Electroencephalography</subject><subject>Electromagnetic Fields</subject><subject>Electronics</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Signal Processing, Computer-Assisted</subject><issn>0967-3334</issn><issn>1361-6579</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkE1Lw0AQhhdRbK3-AQ-Sk-AhZmf2M0cpfhQKguh52SYbiSTZmG0P_fduaKmHgl5mBuaZd-Ah5BroPVCtM5pLlTLGeIYyg-yN4gmZApOQSqHyUzI9ABNyEcIXpQAaxTmZgFActWJTIhZd6XoXS7dOCt_2vhsn29lmG-qQVH5IVrVvXVkXtklC_Rk34ZKcVbG5q32fkY-nx_f5S7p8fV7MH5ZpwQVbpwydpg6tLpwCFDKvQOWalsgLRhFygY6B4Nw6oGWuXE4tIlecYpnTygo2I7e73H7w3xsX1qatQ-GaxnbOb4KRimtAqf8FQTGmlcAI4g4sBh_C4CrTD3Vrh60BakarZpRmRmkGpQETrcajm336ZhVN_J7sNUbgbgfUvj9sj4NMX1aRTY_ZP57_AFYBiyM</recordid><startdate>20050201</startdate><enddate>20050201</enddate><creator>James, Christopher J</creator><creator>Hesse, Christian W</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20050201</creationdate><title>Independent component analysis for biomedical signals</title><author>James, Christopher J ; Hesse, Christian W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Biomedical Technology - trends</topic><topic>Brain - physiology</topic><topic>Electroencephalography</topic><topic>Electromagnetic Fields</topic><topic>Electronics</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Signal Processing, Computer-Assisted</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>James, Christopher J</creatorcontrib><creatorcontrib>Hesse, Christian W</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Physiological measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>James, Christopher J</au><au>Hesse, Christian W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Independent component analysis for biomedical signals</atitle><jtitle>Physiological measurement</jtitle><addtitle>Physiol Meas</addtitle><date>2005-02-01</date><risdate>2005</risdate><volume>26</volume><issue>1</issue><spage>R15</spage><epage>R39</epage><pages>R15-R39</pages><issn>0967-3334</issn><eissn>1361-6579</eissn><abstract>Independent component analysis (ICA) is increasing in popularity in the field of biomedical signal processing. It is generally used when it is required to separate measured multi-channel biomedical signals into their constituent underlying components. The use of ICA has been facilitated in part by the free availability of toolboxes that implement popular flavours of the techniques. Fundamentally ICA in biomedicine involves the extraction and separation of statistically independent sources underlying multiple measurements of biomedical signals. Technical advances in algorithmic developments implementing ICA are reviewed along with new directions in the field. These advances are specifically summarized with applications to biomedical signals in mind. The basic assumptions that are made when applying ICA are discussed, along with their implications when applied particularly to biomedical signals. ICA as a specific embodiment of blind source separation (BSS) is also discussed, and as a consequence the criterion used for establishing independence between sources is reviewed and this leads to the introduction of ICA/BSS techniques based on time, frequency and joint time-frequency decomposition of the data. Finally, advanced implementations of ICA are illustrated as applied to neurophysiologic signals in the form of electro-magnetic brain signals data.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>15742873</pmid><doi>10.1088/0967-3334/26/1/R02</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0967-3334 |
ispartof | Physiological measurement, 2005-02, Vol.26 (1), p.R15-R39 |
issn | 0967-3334 1361-6579 |
language | eng |
recordid | cdi_proquest_miscellaneous_67481268 |
source | Institute of Physics |
subjects | Biomedical Technology - trends Brain - physiology Electroencephalography Electromagnetic Fields Electronics Equipment Design Humans Signal Processing, Computer-Assisted |
title | Independent component analysis for biomedical signals |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T10%3A03%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Independent%20component%20analysis%20for%20biomedical%20signals&rft.jtitle=Physiological%20measurement&rft.au=James,%20Christopher%20J&rft.date=2005-02-01&rft.volume=26&rft.issue=1&rft.spage=R15&rft.epage=R39&rft.pages=R15-R39&rft.issn=0967-3334&rft.eissn=1361-6579&rft_id=info:doi/10.1088/0967-3334/26/1/R02&rft_dat=%3Cproquest_pubme%3E17338752%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c453t-32e80e2a8ce712569f17980d24c3021952e31544ae10d97e90a2247402d90fa53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=17338752&rft_id=info:pmid/15742873&rfr_iscdi=true |