Loading…

Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen

We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological r...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2005-03, Vol.77 (6), p.1771-1779
Main Authors: Konry, T, Novoa, A, Shemer-Avni, Y, Hanuka, N, Cosnier, S, Lepellec, Arielle, Marks, R. S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83
cites cdi_FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83
container_end_page 1779
container_issue 6
container_start_page 1771
container_title Analytical chemistry (Washington)
container_volume 77
creator Konry, T
Novoa, A
Shemer-Avni, Y
Hanuka, N
Cosnier, S
Lepellec, Arielle
Marks, R. S
description We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength ∼345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.
doi_str_mv 10.1021/ac048569w
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67504626</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67504626</sourcerecordid><originalsourceid>FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83</originalsourceid><addsrcrecordid>eNqF0cFu1DAQBuAIgehSOPACyEIC0UNgbMd2ciy7bKlUqZVYceBiOc6EpiR2amdFlyfgzCPyJHi1q64EB06RnO8fe_Rn2XMKbykw-s5YKEohq-8PshkVDHJZluxhNgMAnjMFcJQ9ifEGgFKg8nF2RIWSTJTFLLu7HKfOmp4suxoDOR-GtfMRXfSBvDcRG-IdMeTK95s34yYE3-Pvn79qdD_8eI3OOzxJ0X4gbQpM10gWOKGdupTyLTl1U1f7psNIJk8-dyFdtD37iu5p9qg1fcRn--9xtlp-WM0_5heXZ-fz04vcCBBTXvKaIq1bYFI2jDe2QUDRQlMXdV00leVNQ2vFpYWyAMqVslxgpTiHFCj5cfZ6N3YM_naNcdJDFy32vXHo11FLJaCQTP4X0kpJJSlN8OVf8Mavg0s7aEZVWfGyEAmd7JANPsaArR5DN5iw0RT0tjN931myL_YD1_WAzUHuS0rg1R6YmKpqg3G2iwcnJa8KsXX5znVxwrv7_yZ8S2tyJfTq6pOWC86-zJdnenGYa2w8LPHvA_8Ao6u5-g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217893845</pqid></control><display><type>article</type><title>Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Konry, T ; Novoa, A ; Shemer-Avni, Y ; Hanuka, N ; Cosnier, S ; Lepellec, Arielle ; Marks, R. S</creator><creatorcontrib>Konry, T ; Novoa, A ; Shemer-Avni, Y ; Hanuka, N ; Cosnier, S ; Lepellec, Arielle ; Marks, R. S</creatorcontrib><description>We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength ∼345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac048569w</identifier><identifier>PMID: 15762584</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Antigens ; Benzophenones - chemistry ; Biological and medical sciences ; Biosensing Techniques - methods ; Biosensors ; Biotechnology ; Chemistry ; Enzyme-Linked Immunosorbent Assay ; Exact sciences and technology ; Fiber Optic Technology ; Fundamental and applied biological sciences. Psychology ; General, instrumentation ; Hepacivirus - isolation &amp; purification ; Hepatitis ; Hepatitis C Antibodies - blood ; Hepatitis C virus ; Humans ; Methods. Procedures. Technologies ; Optical Fibers ; Optics ; RNA, Viral - blood ; Various methods and equipments ; Viral Envelope Proteins - immunology</subject><ispartof>Analytical chemistry (Washington), 2005-03, Vol.77 (6), p.1771-1779</ispartof><rights>Copyright © 2005 American Chemical Society</rights><rights>2005 INIST-CNRS</rights><rights>Copyright American Chemical Society Mar 15, 2005</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83</citedby><cites>FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16639454$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15762584$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Konry, T</creatorcontrib><creatorcontrib>Novoa, A</creatorcontrib><creatorcontrib>Shemer-Avni, Y</creatorcontrib><creatorcontrib>Hanuka, N</creatorcontrib><creatorcontrib>Cosnier, S</creatorcontrib><creatorcontrib>Lepellec, Arielle</creatorcontrib><creatorcontrib>Marks, R. S</creatorcontrib><title>Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength ∼345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.</description><subject>Analytical chemistry</subject><subject>Antigens</subject><subject>Benzophenones - chemistry</subject><subject>Biological and medical sciences</subject><subject>Biosensing Techniques - methods</subject><subject>Biosensors</subject><subject>Biotechnology</subject><subject>Chemistry</subject><subject>Enzyme-Linked Immunosorbent Assay</subject><subject>Exact sciences and technology</subject><subject>Fiber Optic Technology</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General, instrumentation</subject><subject>Hepacivirus - isolation &amp; purification</subject><subject>Hepatitis</subject><subject>Hepatitis C Antibodies - blood</subject><subject>Hepatitis C virus</subject><subject>Humans</subject><subject>Methods. Procedures. Technologies</subject><subject>Optical Fibers</subject><subject>Optics</subject><subject>RNA, Viral - blood</subject><subject>Various methods and equipments</subject><subject>Viral Envelope Proteins - immunology</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqF0cFu1DAQBuAIgehSOPACyEIC0UNgbMd2ciy7bKlUqZVYceBiOc6EpiR2amdFlyfgzCPyJHi1q64EB06RnO8fe_Rn2XMKbykw-s5YKEohq-8PshkVDHJZluxhNgMAnjMFcJQ9ifEGgFKg8nF2RIWSTJTFLLu7HKfOmp4suxoDOR-GtfMRXfSBvDcRG-IdMeTK95s34yYE3-Pvn79qdD_8eI3OOzxJ0X4gbQpM10gWOKGdupTyLTl1U1f7psNIJk8-dyFdtD37iu5p9qg1fcRn--9xtlp-WM0_5heXZ-fz04vcCBBTXvKaIq1bYFI2jDe2QUDRQlMXdV00leVNQ2vFpYWyAMqVslxgpTiHFCj5cfZ6N3YM_naNcdJDFy32vXHo11FLJaCQTP4X0kpJJSlN8OVf8Mavg0s7aEZVWfGyEAmd7JANPsaArR5DN5iw0RT0tjN931myL_YD1_WAzUHuS0rg1R6YmKpqg3G2iwcnJa8KsXX5znVxwrv7_yZ8S2tyJfTq6pOWC86-zJdnenGYa2w8LPHvA_8Ao6u5-g</recordid><startdate>20050315</startdate><enddate>20050315</enddate><creator>Konry, T</creator><creator>Novoa, A</creator><creator>Shemer-Avni, Y</creator><creator>Hanuka, N</creator><creator>Cosnier, S</creator><creator>Lepellec, Arielle</creator><creator>Marks, R. S</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20050315</creationdate><title>Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen</title><author>Konry, T ; Novoa, A ; Shemer-Avni, Y ; Hanuka, N ; Cosnier, S ; Lepellec, Arielle ; Marks, R. S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analytical chemistry</topic><topic>Antigens</topic><topic>Benzophenones - chemistry</topic><topic>Biological and medical sciences</topic><topic>Biosensing Techniques - methods</topic><topic>Biosensors</topic><topic>Biotechnology</topic><topic>Chemistry</topic><topic>Enzyme-Linked Immunosorbent Assay</topic><topic>Exact sciences and technology</topic><topic>Fiber Optic Technology</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General, instrumentation</topic><topic>Hepacivirus - isolation &amp; purification</topic><topic>Hepatitis</topic><topic>Hepatitis C Antibodies - blood</topic><topic>Hepatitis C virus</topic><topic>Humans</topic><topic>Methods. Procedures. Technologies</topic><topic>Optical Fibers</topic><topic>Optics</topic><topic>RNA, Viral - blood</topic><topic>Various methods and equipments</topic><topic>Viral Envelope Proteins - immunology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Konry, T</creatorcontrib><creatorcontrib>Novoa, A</creatorcontrib><creatorcontrib>Shemer-Avni, Y</creatorcontrib><creatorcontrib>Hanuka, N</creatorcontrib><creatorcontrib>Cosnier, S</creatorcontrib><creatorcontrib>Lepellec, Arielle</creatorcontrib><creatorcontrib>Marks, R. S</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Konry, T</au><au>Novoa, A</au><au>Shemer-Avni, Y</au><au>Hanuka, N</au><au>Cosnier, S</au><au>Lepellec, Arielle</au><au>Marks, R. S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2005-03-15</date><risdate>2005</risdate><volume>77</volume><issue>6</issue><spage>1771</spage><epage>1779</epage><pages>1771-1779</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength ∼345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>15762584</pmid><doi>10.1021/ac048569w</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2005-03, Vol.77 (6), p.1771-1779
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_67504626
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Antigens
Benzophenones - chemistry
Biological and medical sciences
Biosensing Techniques - methods
Biosensors
Biotechnology
Chemistry
Enzyme-Linked Immunosorbent Assay
Exact sciences and technology
Fiber Optic Technology
Fundamental and applied biological sciences. Psychology
General, instrumentation
Hepacivirus - isolation & purification
Hepatitis
Hepatitis C Antibodies - blood
Hepatitis C virus
Humans
Methods. Procedures. Technologies
Optical Fibers
Optics
RNA, Viral - blood
Various methods and equipments
Viral Envelope Proteins - immunology
title Optical Fiber Immunosensor Based on a Poly(pyrrole−benzophenone) Film for the Detection of Antibodies to Viral Antigen
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T20%3A38%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optical%20Fiber%20Immunosensor%20Based%20on%20a%20Poly(pyrrole%E2%88%92benzophenone)%20Film%20for%20the%20Detection%20of%20Antibodies%20to%20Viral%20Antigen&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Konry,%20T&rft.date=2005-03-15&rft.volume=77&rft.issue=6&rft.spage=1771&rft.epage=1779&rft.pages=1771-1779&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac048569w&rft_dat=%3Cproquest_cross%3E67504626%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a505t-83b1e1bf0266d23dcde0e5f0db4bb4d9c3dd1b736c08401377c35e9733066d83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=217893845&rft_id=info:pmid/15762584&rfr_iscdi=true