Loading…

Choroidal perfusion measurements made with optical coherence tomography

Choroidal perfusion measurements are complicated by the choroid's location posterior to the retina and its associated retinal blood vessels. Optical coherence tomography is a relatively new imaging technique with sufficient spatial resolution to isolate choroidal backscattering events from the...

Full description

Saved in:
Bibliographic Details
Published in:Applied optics (2004) 2005-03, Vol.44 (8), p.1426-1433
Main Authors: Wu, Frank I, Glucksberg, Matthew R
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Choroidal perfusion measurements are complicated by the choroid's location posterior to the retina and its associated retinal blood vessels. Optical coherence tomography is a relatively new imaging technique with sufficient spatial resolution to isolate choroidal backscattering events from the posterior eye. We modified a speckle imaging algorithm to analyze sequential axial depth scans obtained from posterior rat eye to obtain an indicator of choroidal perfusion. This indicator is correlated with known changes in choroidal blood flow in response to increased intraocular pressure.
ISSN:1559-128X
DOI:10.1364/AO.44.001426