Loading…

Three-dimensional analysis of eye movements using four times high-speed video camera

In order to record and analyze the rapid eye movement non-invasively in human subjects, a four times high-speed video camera (4TC) with a new computer software was developed and utilized. Nine healthy volunteers and four patients with vestibular dysfunction participated in this study. Caloric stimul...

Full description

Saved in:
Bibliographic Details
Published in:Auris, nasus, larynx nasus, larynx, 2005-06, Vol.32 (2), p.107-112
Main Authors: Yagi, Toshiaki, Koizumi, Yasuo, Aoyagi, Mio, Kimura, Maki, Sugizaki, Kazuki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553
cites cdi_FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553
container_end_page 112
container_issue 2
container_start_page 107
container_title Auris, nasus, larynx
container_volume 32
creator Yagi, Toshiaki
Koizumi, Yasuo
Aoyagi, Mio
Kimura, Maki
Sugizaki, Kazuki
description In order to record and analyze the rapid eye movement non-invasively in human subjects, a four times high-speed video camera (4TC) with a new computer software was developed and utilized. Nine healthy volunteers and four patients with vestibular dysfunction participated in this study. Caloric stimulation was applied to the healthy subjects and the eye movements were recorded using a standard camera (SC) and a 4TC. In four patients, the positional and/or positioning nystagmus was recorded using SC and 4TC. Analysis of the eye speed of the quick phase of nystagmus was performed manually from the print out of the chart. The quick phase of the caloric nystagmus was adequately analyzed from the data using 4TC. However, using SC the sampling rate was not sufficiently enough for this purpose, as prospected. The adaptability of the 4TC in clinical examination is exactly similar to that of SC, because of the size and weight of the camera. Although the time taken to analyze eye movements using 4TC is about four times longer than that using SC, this system is quite useful and adequate for analyzing the quick eye movements in vestibular nystagmus, in an out-patient clinic set up.
doi_str_mv 10.1016/j.anl.2005.01.001
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67870704</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0385814605000131</els_id><sourcerecordid>67870704</sourcerecordid><originalsourceid>FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553</originalsourceid><addsrcrecordid>eNp9kMFqGzEQhkVJady0D9BL0Sm33c7YWmmXnEJI0kKgF-csZGkUy-yuHGnX4LePgg255TJzmO__YT7GfiHUCCj_7Goz9vUSoKkBawD8whbYqq5CoeQFW8CqbaoWhbxk33PeAcBKrbpv7BKbDhXKZsHW620iqlwYaMwhjqbnpoxjDplHz-lIfIgHKtcp8zmH8YX7OCc-lUDm2_CyrfKeyPFDcBS5NQMl84N99abP9PO8r9jzw_367m_19P_x393tU2WFwKlCT8K7DgSht0BOiabddHYJfum8lLbrWrOUipzbgHceHRiy0jgjGnCyaVZX7PrUu0_xdaY86SFkS31vRopz1lK1ChSIAuIJtCnmnMjrfQqDSUeNoN9V6p0uKvW7Sg2oi8qS-X0unzcDuY_E2V0Bbk4AlRcPgZLONtBoyYVEdtIuhk_q3wC1_IX7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67870704</pqid></control><display><type>article</type><title>Three-dimensional analysis of eye movements using four times high-speed video camera</title><source>ScienceDirect Freedom Collection</source><creator>Yagi, Toshiaki ; Koizumi, Yasuo ; Aoyagi, Mio ; Kimura, Maki ; Sugizaki, Kazuki</creator><creatorcontrib>Yagi, Toshiaki ; Koizumi, Yasuo ; Aoyagi, Mio ; Kimura, Maki ; Sugizaki, Kazuki</creatorcontrib><description>In order to record and analyze the rapid eye movement non-invasively in human subjects, a four times high-speed video camera (4TC) with a new computer software was developed and utilized. Nine healthy volunteers and four patients with vestibular dysfunction participated in this study. Caloric stimulation was applied to the healthy subjects and the eye movements were recorded using a standard camera (SC) and a 4TC. In four patients, the positional and/or positioning nystagmus was recorded using SC and 4TC. Analysis of the eye speed of the quick phase of nystagmus was performed manually from the print out of the chart. The quick phase of the caloric nystagmus was adequately analyzed from the data using 4TC. However, using SC the sampling rate was not sufficiently enough for this purpose, as prospected. The adaptability of the 4TC in clinical examination is exactly similar to that of SC, because of the size and weight of the camera. Although the time taken to analyze eye movements using 4TC is about four times longer than that using SC, this system is quite useful and adequate for analyzing the quick eye movements in vestibular nystagmus, in an out-patient clinic set up.</description><identifier>ISSN: 0385-8146</identifier><identifier>EISSN: 1879-1476</identifier><identifier>DOI: 10.1016/j.anl.2005.01.001</identifier><identifier>PMID: 15917165</identifier><language>eng</language><publisher>Netherlands: Elsevier Ireland Ltd</publisher><subject>3D analysis ; Adult ; Equipment Design ; Eye Movements ; Eye Protective Devices ; High-speed ; Humans ; Imaging, Three-Dimensional ; Nystagmus, Physiologic ; Reference Values ; Time Factors ; Vertigo ; Vestibular ; Video-oculography ; Videotape Recording - instrumentation</subject><ispartof>Auris, nasus, larynx, 2005-06, Vol.32 (2), p.107-112</ispartof><rights>2005 Elsevier Ireland Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553</citedby><cites>FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15917165$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yagi, Toshiaki</creatorcontrib><creatorcontrib>Koizumi, Yasuo</creatorcontrib><creatorcontrib>Aoyagi, Mio</creatorcontrib><creatorcontrib>Kimura, Maki</creatorcontrib><creatorcontrib>Sugizaki, Kazuki</creatorcontrib><title>Three-dimensional analysis of eye movements using four times high-speed video camera</title><title>Auris, nasus, larynx</title><addtitle>Auris Nasus Larynx</addtitle><description>In order to record and analyze the rapid eye movement non-invasively in human subjects, a four times high-speed video camera (4TC) with a new computer software was developed and utilized. Nine healthy volunteers and four patients with vestibular dysfunction participated in this study. Caloric stimulation was applied to the healthy subjects and the eye movements were recorded using a standard camera (SC) and a 4TC. In four patients, the positional and/or positioning nystagmus was recorded using SC and 4TC. Analysis of the eye speed of the quick phase of nystagmus was performed manually from the print out of the chart. The quick phase of the caloric nystagmus was adequately analyzed from the data using 4TC. However, using SC the sampling rate was not sufficiently enough for this purpose, as prospected. The adaptability of the 4TC in clinical examination is exactly similar to that of SC, because of the size and weight of the camera. Although the time taken to analyze eye movements using 4TC is about four times longer than that using SC, this system is quite useful and adequate for analyzing the quick eye movements in vestibular nystagmus, in an out-patient clinic set up.</description><subject>3D analysis</subject><subject>Adult</subject><subject>Equipment Design</subject><subject>Eye Movements</subject><subject>Eye Protective Devices</subject><subject>High-speed</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Nystagmus, Physiologic</subject><subject>Reference Values</subject><subject>Time Factors</subject><subject>Vertigo</subject><subject>Vestibular</subject><subject>Video-oculography</subject><subject>Videotape Recording - instrumentation</subject><issn>0385-8146</issn><issn>1879-1476</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp9kMFqGzEQhkVJady0D9BL0Sm33c7YWmmXnEJI0kKgF-csZGkUy-yuHGnX4LePgg255TJzmO__YT7GfiHUCCj_7Goz9vUSoKkBawD8whbYqq5CoeQFW8CqbaoWhbxk33PeAcBKrbpv7BKbDhXKZsHW620iqlwYaMwhjqbnpoxjDplHz-lIfIgHKtcp8zmH8YX7OCc-lUDm2_CyrfKeyPFDcBS5NQMl84N99abP9PO8r9jzw_367m_19P_x393tU2WFwKlCT8K7DgSht0BOiabddHYJfum8lLbrWrOUipzbgHceHRiy0jgjGnCyaVZX7PrUu0_xdaY86SFkS31vRopz1lK1ChSIAuIJtCnmnMjrfQqDSUeNoN9V6p0uKvW7Sg2oi8qS-X0unzcDuY_E2V0Bbk4AlRcPgZLONtBoyYVEdtIuhk_q3wC1_IX7</recordid><startdate>20050601</startdate><enddate>20050601</enddate><creator>Yagi, Toshiaki</creator><creator>Koizumi, Yasuo</creator><creator>Aoyagi, Mio</creator><creator>Kimura, Maki</creator><creator>Sugizaki, Kazuki</creator><general>Elsevier Ireland Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>8BM</scope></search><sort><creationdate>20050601</creationdate><title>Three-dimensional analysis of eye movements using four times high-speed video camera</title><author>Yagi, Toshiaki ; Koizumi, Yasuo ; Aoyagi, Mio ; Kimura, Maki ; Sugizaki, Kazuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>3D analysis</topic><topic>Adult</topic><topic>Equipment Design</topic><topic>Eye Movements</topic><topic>Eye Protective Devices</topic><topic>High-speed</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Nystagmus, Physiologic</topic><topic>Reference Values</topic><topic>Time Factors</topic><topic>Vertigo</topic><topic>Vestibular</topic><topic>Video-oculography</topic><topic>Videotape Recording - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yagi, Toshiaki</creatorcontrib><creatorcontrib>Koizumi, Yasuo</creatorcontrib><creatorcontrib>Aoyagi, Mio</creatorcontrib><creatorcontrib>Kimura, Maki</creatorcontrib><creatorcontrib>Sugizaki, Kazuki</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>ComDisDome</collection><jtitle>Auris, nasus, larynx</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yagi, Toshiaki</au><au>Koizumi, Yasuo</au><au>Aoyagi, Mio</au><au>Kimura, Maki</au><au>Sugizaki, Kazuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Three-dimensional analysis of eye movements using four times high-speed video camera</atitle><jtitle>Auris, nasus, larynx</jtitle><addtitle>Auris Nasus Larynx</addtitle><date>2005-06-01</date><risdate>2005</risdate><volume>32</volume><issue>2</issue><spage>107</spage><epage>112</epage><pages>107-112</pages><issn>0385-8146</issn><eissn>1879-1476</eissn><abstract>In order to record and analyze the rapid eye movement non-invasively in human subjects, a four times high-speed video camera (4TC) with a new computer software was developed and utilized. Nine healthy volunteers and four patients with vestibular dysfunction participated in this study. Caloric stimulation was applied to the healthy subjects and the eye movements were recorded using a standard camera (SC) and a 4TC. In four patients, the positional and/or positioning nystagmus was recorded using SC and 4TC. Analysis of the eye speed of the quick phase of nystagmus was performed manually from the print out of the chart. The quick phase of the caloric nystagmus was adequately analyzed from the data using 4TC. However, using SC the sampling rate was not sufficiently enough for this purpose, as prospected. The adaptability of the 4TC in clinical examination is exactly similar to that of SC, because of the size and weight of the camera. Although the time taken to analyze eye movements using 4TC is about four times longer than that using SC, this system is quite useful and adequate for analyzing the quick eye movements in vestibular nystagmus, in an out-patient clinic set up.</abstract><cop>Netherlands</cop><pub>Elsevier Ireland Ltd</pub><pmid>15917165</pmid><doi>10.1016/j.anl.2005.01.001</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0385-8146
ispartof Auris, nasus, larynx, 2005-06, Vol.32 (2), p.107-112
issn 0385-8146
1879-1476
language eng
recordid cdi_proquest_miscellaneous_67870704
source ScienceDirect Freedom Collection
subjects 3D analysis
Adult
Equipment Design
Eye Movements
Eye Protective Devices
High-speed
Humans
Imaging, Three-Dimensional
Nystagmus, Physiologic
Reference Values
Time Factors
Vertigo
Vestibular
Video-oculography
Videotape Recording - instrumentation
title Three-dimensional analysis of eye movements using four times high-speed video camera
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T22%3A52%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Three-dimensional%20analysis%20of%20eye%20movements%20using%20four%20times%20high-speed%20video%20camera&rft.jtitle=Auris,%20nasus,%20larynx&rft.au=Yagi,%20Toshiaki&rft.date=2005-06-01&rft.volume=32&rft.issue=2&rft.spage=107&rft.epage=112&rft.pages=107-112&rft.issn=0385-8146&rft.eissn=1879-1476&rft_id=info:doi/10.1016/j.anl.2005.01.001&rft_dat=%3Cproquest_cross%3E67870704%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c441t-1fe4fd904e1fc0ed7458b9c20f2df66c998a267eddb0fdf1d0aec6ada450d6553%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67870704&rft_id=info:pmid/15917165&rfr_iscdi=true