High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity

Screening and processing methods currently in place have made the risk of bacterial and viral infections from allograft tissues extremely low. However, the development of a terminal sterilization method that does not adversely affect tissue function would provide an added safety to tissues for trans...

Full description

Saved in:
Bibliographic Details
Published in:Journal of orthopaedic research 2006-05, Vol.24 (5), p.1011-1018
Main Authors: Grieb, Teri A., Forng, Ren-Yo, Bogdansky, Simon, Ronholdt, Chad, Parks, Brent, Drohan, William N., Burgess, Wilson H., Lin, Jack
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3
cites cdi_FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3
container_end_page 1018
container_issue 5
container_start_page 1011
container_title Journal of orthopaedic research
container_volume 24
creator Grieb, Teri A.
Forng, Ren-Yo
Bogdansky, Simon
Ronholdt, Chad
Parks, Brent
Drohan, William N.
Burgess, Wilson H.
Lin, Jack
description Screening and processing methods currently in place have made the risk of bacterial and viral infections from allograft tissues extremely low. However, the development of a terminal sterilization method that does not adversely affect tissue function would provide an added safety to tissues for transplantation. We assessed whether high‐dose gamma irradiation could be used as an effective terminal sterilization method for allografts without impairing the preimplantation mechanical integrity of the tissues. Semitendinosus tendons were pretreated with a radioprotectant solution and then irradiated to 50 kGy under well‐defined conditions that included a tight dose range and maintained low temperatures. Maximum force, strain, stress, modulus, and strain energy density for tendons irradiated to 50 kGy were compared to nonirradiated control tendons and tendons irradiated to 18 kGy by a commercial tissue bank using their existing method. The preimplantation biomechanical properties of the 50‐kGy group compared favorably to the nonirradiated and 18 kGy groups. A study to evaluate the postimplantation mechanical and biological performance of grafts irradiated to 50 kGy is ongoing. Pathogen inactivation was also quantified following 50 kGy of irradiation, with ≥4.5 logs of Sindbis virus and 4.9 logs of parvovirus kill achieved. Analysis of Clostridium sordellii inactivation kinetics indicated that a 16 log10 reduction is predicted with 50 kGy of irradiation. A high dose of gamma irradiation using the described conditions can reduce infectious risks associated with soft tissue allografts while maintaining the preimplantation biomechanical performance of the tissues. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res
doi_str_mv 10.1002/jor.20079
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67921605</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67921605</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3</originalsourceid><addsrcrecordid>eNp1kM1OGzEURq2qqKTQRV-g8qoSiyG2Z2zPdFchIFQRIBQEO8vjn4nTmXGwHdG8PaYJ7YrVla7Od3TvB8BXjE4xQmS68uGUIMSbD2CCKa0KSvjjRzBBvGQFIowdgs8xrlBGMKk_gUPMKK4YqSZgNXPdstA-GtjJYZDQhSC1k8n5EVofYPQ2weRi3Bgo-953QdoUf8DXHBxk6NwIvYVRWpO28NmlJWydH4xaytEp2UM3JtMFl7bH4MDKPpov-3kE7i_OF2ezYn5zeXX2c16osmFNwZHBjaF1_qFSiBhdU1Vr0lLKcUVUqXGr6hqzVuu21BVusaxlZS3neW9rWR6B7zvvOvinjYlJDC4q0_dyNH4TBeMNwQzRDJ7sQBV8jMFYsQ4uv7QVGInXYkUuVvwtNrPf9tJNOxj9n9w3mYHpDnh2vdm-bxK_bu7elMUu4WIyf_4lZPidTyw5FQ_XlwIt5vwWV0gsyhebfpL6</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67921605</pqid></control><display><type>article</type><title>High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Grieb, Teri A. ; Forng, Ren-Yo ; Bogdansky, Simon ; Ronholdt, Chad ; Parks, Brent ; Drohan, William N. ; Burgess, Wilson H. ; Lin, Jack</creator><creatorcontrib>Grieb, Teri A. ; Forng, Ren-Yo ; Bogdansky, Simon ; Ronholdt, Chad ; Parks, Brent ; Drohan, William N. ; Burgess, Wilson H. ; Lin, Jack</creatorcontrib><description>Screening and processing methods currently in place have made the risk of bacterial and viral infections from allograft tissues extremely low. However, the development of a terminal sterilization method that does not adversely affect tissue function would provide an added safety to tissues for transplantation. We assessed whether high‐dose gamma irradiation could be used as an effective terminal sterilization method for allografts without impairing the preimplantation mechanical integrity of the tissues. Semitendinosus tendons were pretreated with a radioprotectant solution and then irradiated to 50 kGy under well‐defined conditions that included a tight dose range and maintained low temperatures. Maximum force, strain, stress, modulus, and strain energy density for tendons irradiated to 50 kGy were compared to nonirradiated control tendons and tendons irradiated to 18 kGy by a commercial tissue bank using their existing method. The preimplantation biomechanical properties of the 50‐kGy group compared favorably to the nonirradiated and 18 kGy groups. A study to evaluate the postimplantation mechanical and biological performance of grafts irradiated to 50 kGy is ongoing. Pathogen inactivation was also quantified following 50 kGy of irradiation, with ≥4.5 logs of Sindbis virus and 4.9 logs of parvovirus kill achieved. Analysis of Clostridium sordellii inactivation kinetics indicated that a 16 log10 reduction is predicted with 50 kGy of irradiation. A high dose of gamma irradiation using the described conditions can reduce infectious risks associated with soft tissue allografts while maintaining the preimplantation biomechanical performance of the tissues. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res</description><identifier>ISSN: 0736-0266</identifier><identifier>EISSN: 1554-527X</identifier><identifier>DOI: 10.1002/jor.20079</identifier><identifier>PMID: 16514624</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Adolescent ; Adult ; allografts ; Biomechanical Phenomena ; biomechanical properties ; Clostridium sordellii - radiation effects ; gamma irradiation ; Gamma Rays - adverse effects ; Humans ; Middle Aged ; pathogen inactivation ; Safety ; Sterilization ; Tendons - microbiology ; Tendons - physiology ; Tendons - radiation effects ; Tendons - transplantation ; Tensile Strength ; Transplantation, Homologous</subject><ispartof>Journal of orthopaedic research, 2006-05, Vol.24 (5), p.1011-1018</ispartof><rights>Copyright © 2006 Orthopaedic Research Society.</rights><rights>Copyright 2006 Orthopaedic Research Society.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3</citedby><cites>FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16514624$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Grieb, Teri A.</creatorcontrib><creatorcontrib>Forng, Ren-Yo</creatorcontrib><creatorcontrib>Bogdansky, Simon</creatorcontrib><creatorcontrib>Ronholdt, Chad</creatorcontrib><creatorcontrib>Parks, Brent</creatorcontrib><creatorcontrib>Drohan, William N.</creatorcontrib><creatorcontrib>Burgess, Wilson H.</creatorcontrib><creatorcontrib>Lin, Jack</creatorcontrib><title>High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity</title><title>Journal of orthopaedic research</title><addtitle>J. Orthop. Res</addtitle><description>Screening and processing methods currently in place have made the risk of bacterial and viral infections from allograft tissues extremely low. However, the development of a terminal sterilization method that does not adversely affect tissue function would provide an added safety to tissues for transplantation. We assessed whether high‐dose gamma irradiation could be used as an effective terminal sterilization method for allografts without impairing the preimplantation mechanical integrity of the tissues. Semitendinosus tendons were pretreated with a radioprotectant solution and then irradiated to 50 kGy under well‐defined conditions that included a tight dose range and maintained low temperatures. Maximum force, strain, stress, modulus, and strain energy density for tendons irradiated to 50 kGy were compared to nonirradiated control tendons and tendons irradiated to 18 kGy by a commercial tissue bank using their existing method. The preimplantation biomechanical properties of the 50‐kGy group compared favorably to the nonirradiated and 18 kGy groups. A study to evaluate the postimplantation mechanical and biological performance of grafts irradiated to 50 kGy is ongoing. Pathogen inactivation was also quantified following 50 kGy of irradiation, with ≥4.5 logs of Sindbis virus and 4.9 logs of parvovirus kill achieved. Analysis of Clostridium sordellii inactivation kinetics indicated that a 16 log10 reduction is predicted with 50 kGy of irradiation. A high dose of gamma irradiation using the described conditions can reduce infectious risks associated with soft tissue allografts while maintaining the preimplantation biomechanical performance of the tissues. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res</description><subject>Adolescent</subject><subject>Adult</subject><subject>allografts</subject><subject>Biomechanical Phenomena</subject><subject>biomechanical properties</subject><subject>Clostridium sordellii - radiation effects</subject><subject>gamma irradiation</subject><subject>Gamma Rays - adverse effects</subject><subject>Humans</subject><subject>Middle Aged</subject><subject>pathogen inactivation</subject><subject>Safety</subject><subject>Sterilization</subject><subject>Tendons - microbiology</subject><subject>Tendons - physiology</subject><subject>Tendons - radiation effects</subject><subject>Tendons - transplantation</subject><subject>Tensile Strength</subject><subject>Transplantation, Homologous</subject><issn>0736-0266</issn><issn>1554-527X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp1kM1OGzEURq2qqKTQRV-g8qoSiyG2Z2zPdFchIFQRIBQEO8vjn4nTmXGwHdG8PaYJ7YrVla7Od3TvB8BXjE4xQmS68uGUIMSbD2CCKa0KSvjjRzBBvGQFIowdgs8xrlBGMKk_gUPMKK4YqSZgNXPdstA-GtjJYZDQhSC1k8n5EVofYPQ2weRi3Bgo-953QdoUf8DXHBxk6NwIvYVRWpO28NmlJWydH4xaytEp2UM3JtMFl7bH4MDKPpov-3kE7i_OF2ezYn5zeXX2c16osmFNwZHBjaF1_qFSiBhdU1Vr0lLKcUVUqXGr6hqzVuu21BVusaxlZS3neW9rWR6B7zvvOvinjYlJDC4q0_dyNH4TBeMNwQzRDJ7sQBV8jMFYsQ4uv7QVGInXYkUuVvwtNrPf9tJNOxj9n9w3mYHpDnh2vdm-bxK_bu7elMUu4WIyf_4lZPidTyw5FQ_XlwIt5vwWV0gsyhebfpL6</recordid><startdate>200605</startdate><enddate>200605</enddate><creator>Grieb, Teri A.</creator><creator>Forng, Ren-Yo</creator><creator>Bogdansky, Simon</creator><creator>Ronholdt, Chad</creator><creator>Parks, Brent</creator><creator>Drohan, William N.</creator><creator>Burgess, Wilson H.</creator><creator>Lin, Jack</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200605</creationdate><title>High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity</title><author>Grieb, Teri A. ; Forng, Ren-Yo ; Bogdansky, Simon ; Ronholdt, Chad ; Parks, Brent ; Drohan, William N. ; Burgess, Wilson H. ; Lin, Jack</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>allografts</topic><topic>Biomechanical Phenomena</topic><topic>biomechanical properties</topic><topic>Clostridium sordellii - radiation effects</topic><topic>gamma irradiation</topic><topic>Gamma Rays - adverse effects</topic><topic>Humans</topic><topic>Middle Aged</topic><topic>pathogen inactivation</topic><topic>Safety</topic><topic>Sterilization</topic><topic>Tendons - microbiology</topic><topic>Tendons - physiology</topic><topic>Tendons - radiation effects</topic><topic>Tendons - transplantation</topic><topic>Tensile Strength</topic><topic>Transplantation, Homologous</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Grieb, Teri A.</creatorcontrib><creatorcontrib>Forng, Ren-Yo</creatorcontrib><creatorcontrib>Bogdansky, Simon</creatorcontrib><creatorcontrib>Ronholdt, Chad</creatorcontrib><creatorcontrib>Parks, Brent</creatorcontrib><creatorcontrib>Drohan, William N.</creatorcontrib><creatorcontrib>Burgess, Wilson H.</creatorcontrib><creatorcontrib>Lin, Jack</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of orthopaedic research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Grieb, Teri A.</au><au>Forng, Ren-Yo</au><au>Bogdansky, Simon</au><au>Ronholdt, Chad</au><au>Parks, Brent</au><au>Drohan, William N.</au><au>Burgess, Wilson H.</au><au>Lin, Jack</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity</atitle><jtitle>Journal of orthopaedic research</jtitle><addtitle>J. Orthop. Res</addtitle><date>2006-05</date><risdate>2006</risdate><volume>24</volume><issue>5</issue><spage>1011</spage><epage>1018</epage><pages>1011-1018</pages><issn>0736-0266</issn><eissn>1554-527X</eissn><abstract>Screening and processing methods currently in place have made the risk of bacterial and viral infections from allograft tissues extremely low. However, the development of a terminal sterilization method that does not adversely affect tissue function would provide an added safety to tissues for transplantation. We assessed whether high‐dose gamma irradiation could be used as an effective terminal sterilization method for allografts without impairing the preimplantation mechanical integrity of the tissues. Semitendinosus tendons were pretreated with a radioprotectant solution and then irradiated to 50 kGy under well‐defined conditions that included a tight dose range and maintained low temperatures. Maximum force, strain, stress, modulus, and strain energy density for tendons irradiated to 50 kGy were compared to nonirradiated control tendons and tendons irradiated to 18 kGy by a commercial tissue bank using their existing method. The preimplantation biomechanical properties of the 50‐kGy group compared favorably to the nonirradiated and 18 kGy groups. A study to evaluate the postimplantation mechanical and biological performance of grafts irradiated to 50 kGy is ongoing. Pathogen inactivation was also quantified following 50 kGy of irradiation, with ≥4.5 logs of Sindbis virus and 4.9 logs of parvovirus kill achieved. Analysis of Clostridium sordellii inactivation kinetics indicated that a 16 log10 reduction is predicted with 50 kGy of irradiation. A high dose of gamma irradiation using the described conditions can reduce infectious risks associated with soft tissue allografts while maintaining the preimplantation biomechanical performance of the tissues. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>16514624</pmid><doi>10.1002/jor.20079</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0736-0266
ispartof Journal of orthopaedic research, 2006-05, Vol.24 (5), p.1011-1018
issn 0736-0266
1554-527X
language eng
recordid cdi_proquest_miscellaneous_67921605
source Wiley-Blackwell Read & Publish Collection
subjects Adolescent
Adult
allografts
Biomechanical Phenomena
biomechanical properties
Clostridium sordellii - radiation effects
gamma irradiation
Gamma Rays - adverse effects
Humans
Middle Aged
pathogen inactivation
Safety
Sterilization
Tendons - microbiology
Tendons - physiology
Tendons - radiation effects
Tendons - transplantation
Tensile Strength
Transplantation, Homologous
title High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T06%3A29%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-dose%20gamma%20irradiation%20for%20soft%20tissue%20allografts:%20High%20margin%20of%20safety%20with%20biomechanical%20integrity&rft.jtitle=Journal%20of%20orthopaedic%20research&rft.au=Grieb,%20Teri%20A.&rft.date=2006-05&rft.volume=24&rft.issue=5&rft.spage=1011&rft.epage=1018&rft.pages=1011-1018&rft.issn=0736-0266&rft.eissn=1554-527X&rft_id=info:doi/10.1002/jor.20079&rft_dat=%3Cproquest_cross%3E67921605%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3969-70e19e585274c02ed85c8d2b557142c3d1bc8816bddb3d41b1a8a4ff77bc8f8a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67921605&rft_id=info:pmid/16514624&rfr_iscdi=true