Validation of EuroSCORE model in an Australian patient population
Background: The purpose of the present paper was to assess the performance of the European system for cardiac operative risk evaluation (EuroSCORE) model in an Australian adult cardiac surgical population. Methods: The additive and logistic EuroSCORE models were retrospectively applied to predict...
Saved in:
Published in: | ANZ journal of surgery 2005-07, Vol.75 (7), p.508-512 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background: The purpose of the present paper was to assess the performance of the European system for cardiac operative risk evaluation (EuroSCORE) model in an Australian adult cardiac surgical population.
Methods: The additive and logistic EuroSCORE models were retrospectively applied to predict operative mortality in 2106 consecutive patients undergoing cardiac surgery at St Vincent's Hospital, Melbourne between June 2001 and August 2003, and at Geelong Hospital between June 2001 and April 2004. The entire cohort and a subset of patients undergoing isolated coronary artery bypass graft (CABG) surgery were analysed. Model discrimination and calibration was tested by determining the area under the receiver operating characteristic (ROC) curve and Hosmer−Lemeshow χ2, respectively.
Results: There were significant differences in the prevalence of risk factors between the Australian and European cardiac surgical populations. There were 81 deaths (observed mortality 3.85%) in the entire cohort and 39 deaths in the isolated CABG group (observed mortality 2.60%). The EuroSCORE models overestimated mortality (entire cohort: additive predicted 5.75%, logistic predicted 9.93%; isolated CABG: additive predicted 4.87%, logistic predicted 7.71%). Discriminative power was very good for the entire cohort (area under ROC curve, 0.81 (additive) and 0.82 (logistic)). Calibration of both models was poor.
Conclusion: The additive and logistic EuroSCORE model of risk prediction was not validated in the present population of cardiac surgical patients. The models may not accurately predict outcomes of patients undergoing cardiac surgery in Australia. |
---|---|