Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia

Most US hospitals use visual inspection for the detection of cerebrospinal fluid xanthrochromia. We compared visual inspection with spectrophotometric xanthrochromia and studied the effect of tube diameter on the sensitivity of visual inspection. Blinded, experienced laboratory technicians visually...

Full description

Saved in:
Bibliographic Details
Published in:Annals of emergency medicine 2005-07, Vol.46 (1), p.51-55
Main Authors: Sidman, Robert, Spitalnic, Stuart, Demelis, Michael, Durfey, Nicole, Jay, Gregory
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903
cites cdi_FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903
container_end_page 55
container_issue 1
container_start_page 51
container_title Annals of emergency medicine
container_volume 46
creator Sidman, Robert
Spitalnic, Stuart
Demelis, Michael
Durfey, Nicole
Jay, Gregory
description Most US hospitals use visual inspection for the detection of cerebrospinal fluid xanthrochromia. We compared visual inspection with spectrophotometric xanthrochromia and studied the effect of tube diameter on the sensitivity of visual inspection. Blinded, experienced laboratory technicians visually examined unmarked samples to determine the presence or absence of xanthrochromia. Samples were prepared by lysing RBCs in distilled water. Serial dilutions were placed in clear polystyrene tubes obtained from standard lumbar puncture trays. Laboratory technicians were asked to examine each sample for xanthrochromia using visual inspection. Next, they were asked to interpret the same set of samples with the assistance of a threshold standard. Last, they were asked to interpret the same dilutions, but this time presented in a larger-diameter tube. The absorbance of each sample was measured in a double-beam spectrophotometer at wavelengths between 300 and 700 nm. Samples were said to demonstrate spectrophotometric xanthrochromia if they had an absorbance greater than 0.023 at 415 nm. Sixteen laboratory technicians were shown a total of 160 samples, of which 64 (40%) demonstrated spectrophotometric xanthrochromia. Visual inspection of the samples was 26.6% sensitive (95% confidence interval [CI] 16% to 38%) and 97.9% specific (95% CI 95% to 100%) for spectrophotometric xanthrochromia. Using a reference standard did not improve the performance of visual inspection, but increasing collection-tube diameter increased the sensitivity to 55% (95% CI 43% to 68%). Visual inspection is not sensitive for the detection of spectrophotometric xanthrochromia. Increasing the diameter of the collection tubes did improve sensitivity. Emergency physicians should be aware of how xanthrochromia is determined at their institutions and understand the implications of using visual detection to determine the presence or absence of xanthrochromia.
doi_str_mv 10.1016/j.annemergmed.2004.11.008
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67981000</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0196064404016798</els_id><sourcerecordid>67981000</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903</originalsourceid><addsrcrecordid>eNqNkE1v1DAQhq0KRJeWv4DMAW4JY8dx4lNVVnxJrXpooT0gWV5nzHqVxMHOIvXf16tdteXGwZqDn5l55yHkHYOSAZMfN6UZRxww_h6wKzmAKBkrAdojsmCgmkI2El6QBTAlC5BCHJPXKW0AQAnOXpFjVqu2FVwuyK87M87rGGx-gzdn9NM9vV2bmV7ivA7dGT2nyzBMJvoURhoc_enT1vTUjB29ntDOMUzrMIcB5-gt_XfaKXnpTJ_wzaGekB9fPt8svxUXV1-_L88vCiugnotaVo1rLXd1JSwH4arVCruWS8u7StSicaLJySWqirUrRCuhBomcGceqSkF1Qj7s504x_NlimvXgk8W-NyOGbdKyUS3L12dQ7UEbQ0oRnZ6iH0y81wz0Tq3e6Gdq9U6tZkxntbn37WHJdrX7e-w8uMzA-wNgkjW9i2a0Pj1xUnEm5S7Ecs9hVvLXY9TJehwtdj5moboL_j_iPAD8tZ1P</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67981000</pqid></control><display><type>article</type><title>Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia</title><source>Elsevier</source><creator>Sidman, Robert ; Spitalnic, Stuart ; Demelis, Michael ; Durfey, Nicole ; Jay, Gregory</creator><creatorcontrib>Sidman, Robert ; Spitalnic, Stuart ; Demelis, Michael ; Durfey, Nicole ; Jay, Gregory</creatorcontrib><description>Most US hospitals use visual inspection for the detection of cerebrospinal fluid xanthrochromia. We compared visual inspection with spectrophotometric xanthrochromia and studied the effect of tube diameter on the sensitivity of visual inspection. Blinded, experienced laboratory technicians visually examined unmarked samples to determine the presence or absence of xanthrochromia. Samples were prepared by lysing RBCs in distilled water. Serial dilutions were placed in clear polystyrene tubes obtained from standard lumbar puncture trays. Laboratory technicians were asked to examine each sample for xanthrochromia using visual inspection. Next, they were asked to interpret the same set of samples with the assistance of a threshold standard. Last, they were asked to interpret the same dilutions, but this time presented in a larger-diameter tube. The absorbance of each sample was measured in a double-beam spectrophotometer at wavelengths between 300 and 700 nm. Samples were said to demonstrate spectrophotometric xanthrochromia if they had an absorbance greater than 0.023 at 415 nm. Sixteen laboratory technicians were shown a total of 160 samples, of which 64 (40%) demonstrated spectrophotometric xanthrochromia. Visual inspection of the samples was 26.6% sensitive (95% confidence interval [CI] 16% to 38%) and 97.9% specific (95% CI 95% to 100%) for spectrophotometric xanthrochromia. Using a reference standard did not improve the performance of visual inspection, but increasing collection-tube diameter increased the sensitivity to 55% (95% CI 43% to 68%). Visual inspection is not sensitive for the detection of spectrophotometric xanthrochromia. Increasing the diameter of the collection tubes did improve sensitivity. Emergency physicians should be aware of how xanthrochromia is determined at their institutions and understand the implications of using visual detection to determine the presence or absence of xanthrochromia.</description><identifier>ISSN: 0196-0644</identifier><identifier>EISSN: 1097-6760</identifier><identifier>DOI: 10.1016/j.annemergmed.2004.11.008</identifier><identifier>PMID: 15988426</identifier><identifier>CODEN: AEMED3</identifier><language>eng</language><publisher>New York, NY: Mosby, Inc</publisher><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Blood coagulation ; Cardiovascular system ; Cerebrospinal Fluid - chemistry ; Clinical Laboratory Techniques - methods ; Humans ; Intensive care medicine ; Investigative techniques of hemodynamics ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Reference Standards ; Reproducibility of Results ; Sensitivity and Specificity ; Spectrophotometry - methods ; Subarachnoid Hemorrhage - cerebrospinal fluid ; Subarachnoid Hemorrhage - diagnosis</subject><ispartof>Annals of emergency medicine, 2005-07, Vol.46 (1), p.51-55</ispartof><rights>2005 American College of Emergency Physicians</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903</citedby><cites>FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16921660$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15988426$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sidman, Robert</creatorcontrib><creatorcontrib>Spitalnic, Stuart</creatorcontrib><creatorcontrib>Demelis, Michael</creatorcontrib><creatorcontrib>Durfey, Nicole</creatorcontrib><creatorcontrib>Jay, Gregory</creatorcontrib><title>Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia</title><title>Annals of emergency medicine</title><addtitle>Ann Emerg Med</addtitle><description>Most US hospitals use visual inspection for the detection of cerebrospinal fluid xanthrochromia. We compared visual inspection with spectrophotometric xanthrochromia and studied the effect of tube diameter on the sensitivity of visual inspection. Blinded, experienced laboratory technicians visually examined unmarked samples to determine the presence or absence of xanthrochromia. Samples were prepared by lysing RBCs in distilled water. Serial dilutions were placed in clear polystyrene tubes obtained from standard lumbar puncture trays. Laboratory technicians were asked to examine each sample for xanthrochromia using visual inspection. Next, they were asked to interpret the same set of samples with the assistance of a threshold standard. Last, they were asked to interpret the same dilutions, but this time presented in a larger-diameter tube. The absorbance of each sample was measured in a double-beam spectrophotometer at wavelengths between 300 and 700 nm. Samples were said to demonstrate spectrophotometric xanthrochromia if they had an absorbance greater than 0.023 at 415 nm. Sixteen laboratory technicians were shown a total of 160 samples, of which 64 (40%) demonstrated spectrophotometric xanthrochromia. Visual inspection of the samples was 26.6% sensitive (95% confidence interval [CI] 16% to 38%) and 97.9% specific (95% CI 95% to 100%) for spectrophotometric xanthrochromia. Using a reference standard did not improve the performance of visual inspection, but increasing collection-tube diameter increased the sensitivity to 55% (95% CI 43% to 68%). Visual inspection is not sensitive for the detection of spectrophotometric xanthrochromia. Increasing the diameter of the collection tubes did improve sensitivity. Emergency physicians should be aware of how xanthrochromia is determined at their institutions and understand the implications of using visual detection to determine the presence or absence of xanthrochromia.</description><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Blood coagulation</subject><subject>Cardiovascular system</subject><subject>Cerebrospinal Fluid - chemistry</subject><subject>Clinical Laboratory Techniques - methods</subject><subject>Humans</subject><subject>Intensive care medicine</subject><subject>Investigative techniques of hemodynamics</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Spectrophotometry - methods</subject><subject>Subarachnoid Hemorrhage - cerebrospinal fluid</subject><subject>Subarachnoid Hemorrhage - diagnosis</subject><issn>0196-0644</issn><issn>1097-6760</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqNkE1v1DAQhq0KRJeWv4DMAW4JY8dx4lNVVnxJrXpooT0gWV5nzHqVxMHOIvXf16tdteXGwZqDn5l55yHkHYOSAZMfN6UZRxww_h6wKzmAKBkrAdojsmCgmkI2El6QBTAlC5BCHJPXKW0AQAnOXpFjVqu2FVwuyK87M87rGGx-gzdn9NM9vV2bmV7ivA7dGT2nyzBMJvoURhoc_enT1vTUjB29ntDOMUzrMIcB5-gt_XfaKXnpTJ_wzaGekB9fPt8svxUXV1-_L88vCiugnotaVo1rLXd1JSwH4arVCruWS8u7StSicaLJySWqirUrRCuhBomcGceqSkF1Qj7s504x_NlimvXgk8W-NyOGbdKyUS3L12dQ7UEbQ0oRnZ6iH0y81wz0Tq3e6Gdq9U6tZkxntbn37WHJdrX7e-w8uMzA-wNgkjW9i2a0Pj1xUnEm5S7Ecs9hVvLXY9TJehwtdj5moboL_j_iPAD8tZ1P</recordid><startdate>20050701</startdate><enddate>20050701</enddate><creator>Sidman, Robert</creator><creator>Spitalnic, Stuart</creator><creator>Demelis, Michael</creator><creator>Durfey, Nicole</creator><creator>Jay, Gregory</creator><general>Mosby, Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050701</creationdate><title>Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia</title><author>Sidman, Robert ; Spitalnic, Stuart ; Demelis, Michael ; Durfey, Nicole ; Jay, Gregory</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Blood coagulation</topic><topic>Cardiovascular system</topic><topic>Cerebrospinal Fluid - chemistry</topic><topic>Clinical Laboratory Techniques - methods</topic><topic>Humans</topic><topic>Intensive care medicine</topic><topic>Investigative techniques of hemodynamics</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Spectrophotometry - methods</topic><topic>Subarachnoid Hemorrhage - cerebrospinal fluid</topic><topic>Subarachnoid Hemorrhage - diagnosis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sidman, Robert</creatorcontrib><creatorcontrib>Spitalnic, Stuart</creatorcontrib><creatorcontrib>Demelis, Michael</creatorcontrib><creatorcontrib>Durfey, Nicole</creatorcontrib><creatorcontrib>Jay, Gregory</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of emergency medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sidman, Robert</au><au>Spitalnic, Stuart</au><au>Demelis, Michael</au><au>Durfey, Nicole</au><au>Jay, Gregory</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia</atitle><jtitle>Annals of emergency medicine</jtitle><addtitle>Ann Emerg Med</addtitle><date>2005-07-01</date><risdate>2005</risdate><volume>46</volume><issue>1</issue><spage>51</spage><epage>55</epage><pages>51-55</pages><issn>0196-0644</issn><eissn>1097-6760</eissn><coden>AEMED3</coden><abstract>Most US hospitals use visual inspection for the detection of cerebrospinal fluid xanthrochromia. We compared visual inspection with spectrophotometric xanthrochromia and studied the effect of tube diameter on the sensitivity of visual inspection. Blinded, experienced laboratory technicians visually examined unmarked samples to determine the presence or absence of xanthrochromia. Samples were prepared by lysing RBCs in distilled water. Serial dilutions were placed in clear polystyrene tubes obtained from standard lumbar puncture trays. Laboratory technicians were asked to examine each sample for xanthrochromia using visual inspection. Next, they were asked to interpret the same set of samples with the assistance of a threshold standard. Last, they were asked to interpret the same dilutions, but this time presented in a larger-diameter tube. The absorbance of each sample was measured in a double-beam spectrophotometer at wavelengths between 300 and 700 nm. Samples were said to demonstrate spectrophotometric xanthrochromia if they had an absorbance greater than 0.023 at 415 nm. Sixteen laboratory technicians were shown a total of 160 samples, of which 64 (40%) demonstrated spectrophotometric xanthrochromia. Visual inspection of the samples was 26.6% sensitive (95% confidence interval [CI] 16% to 38%) and 97.9% specific (95% CI 95% to 100%) for spectrophotometric xanthrochromia. Using a reference standard did not improve the performance of visual inspection, but increasing collection-tube diameter increased the sensitivity to 55% (95% CI 43% to 68%). Visual inspection is not sensitive for the detection of spectrophotometric xanthrochromia. Increasing the diameter of the collection tubes did improve sensitivity. Emergency physicians should be aware of how xanthrochromia is determined at their institutions and understand the implications of using visual detection to determine the presence or absence of xanthrochromia.</abstract><cop>New York, NY</cop><pub>Mosby, Inc</pub><pmid>15988426</pmid><doi>10.1016/j.annemergmed.2004.11.008</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0196-0644
ispartof Annals of emergency medicine, 2005-07, Vol.46 (1), p.51-55
issn 0196-0644
1097-6760
language eng
recordid cdi_proquest_miscellaneous_67981000
source Elsevier
subjects Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Blood coagulation
Cardiovascular system
Cerebrospinal Fluid - chemistry
Clinical Laboratory Techniques - methods
Humans
Intensive care medicine
Investigative techniques of hemodynamics
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Reference Standards
Reproducibility of Results
Sensitivity and Specificity
Spectrophotometry - methods
Subarachnoid Hemorrhage - cerebrospinal fluid
Subarachnoid Hemorrhage - diagnosis
title Xanthrochromia? By What Method? A Comparison of Visual and Spectrophotometric Xanthrochromia
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T13%3A10%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Xanthrochromia?%20By%20What%20Method?%20A%20Comparison%20of%20Visual%20and%20Spectrophotometric%20Xanthrochromia&rft.jtitle=Annals%20of%20emergency%20medicine&rft.au=Sidman,%20Robert&rft.date=2005-07-01&rft.volume=46&rft.issue=1&rft.spage=51&rft.epage=55&rft.pages=51-55&rft.issn=0196-0644&rft.eissn=1097-6760&rft.coden=AEMED3&rft_id=info:doi/10.1016/j.annemergmed.2004.11.008&rft_dat=%3Cproquest_cross%3E67981000%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c405t-5637f8c2f534c204f3bbed826c2d34547f470946e9318beec60506e21af133903%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67981000&rft_id=info:pmid/15988426&rfr_iscdi=true