Loading…

Intensity-modulated radiotherapy of breast cancer using direct aperture optimization

To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. The DAO technique implemented in the Pinnacle treatmen...

Full description

Saved in:
Bibliographic Details
Published in:Radiotherapy and oncology 2006-05, Vol.79 (2), p.162-169
Main Authors: van Asselen, Bram, Schwarz, Marco, van Vliet-Vroegindeweij, Corine, Lebesque, Joos V., Mijnheer, Ben J., Damen, Eugene M.F.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293
cites cdi_FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293
container_end_page 169
container_issue 2
container_start_page 162
container_title Radiotherapy and oncology
container_volume 79
creator van Asselen, Bram
Schwarz, Marco
van Vliet-Vroegindeweij, Corine
Lebesque, Joos V.
Mijnheer, Ben J.
Damen, Eugene M.F.
description To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. The DAO technique implemented in the Pinnacle treatment planning system, which is called direct machine parameter optimization (DMPO), was used to generate IMRT plans for twelve breast cancer patients. The prescribed dose was 50 Gy. Two DMPO plans were generated. The first approach uses DMPO only; the second technique combines DMPO with two predefined segments (DMPO segm), having shapes identical to the conventional tangential fields. The weight of these predefined segments is optimized simultaneously with DMPO. The DMPO plans were compared with normal two-step (TS) IMRT, creating segments after optimizing the intensity. Dose homogeneity within the target volume was 4.8±0.6, 4.3±0.5 and 3.8±0.5 Gy for the TS, DMPO and DMPO segm plans, respectively. Comparing the IMRT plans with an idealized dose distribution obtained using only beamlet optimization, the degradation of the dose distribution was less for the DMPO plans compared with the two-step IMRT approach. Furthermore, this degradation was similar for all patients, while for the two-step IMRT approach it was patient specific. An efficient step-and-shoot IMRT solution was developed for the treatment of breast cancer using DMPO combined with two predefined segments.
doi_str_mv 10.1016/j.radonc.2006.04.010
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68092286</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0167814006001812</els_id><sourcerecordid>68092286</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293</originalsourceid><addsrcrecordid>eNp9kMFq3DAQhkVoSTZp3iAUn3qzM5K1lnUJhJC2gUAv6VnI0ijRsrZcSQ5snj4KXsitp4Hh-_9hPkKuKDQUaHe9a6K2YTINA-ga4A1QOCEb2gtZQ9-LL2RTMFH3lMMZOU9pBwAMWnFKzsqeMinZhjw9TBmn5POhHoNd9jqjrUqxD_kFo54PVXDVEFGnXBk9GYzVkvz0XFkf0eRKzxjzErEKc_ajf9PZh-kb-er0PuHlcV6Qvz_vn-5-149_fj3c3T7Wpu0g18ihdVxQq53YMiu2tBvosBUCLHSgrRADb53opTNbzV3PrOy4dMj1IDUy2V6QH2vvHMO_BVNWo08G93s9YViS6nqQjPVdAfkKmhhSiujUHP2o40FRUB821U6tNtWHTQVcFZsl9v3Yvwwj2s_QUV8BblYAy5evHqNKxmOxtNpRNvj_X3gHWwSJew</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68092286</pqid></control><display><type>article</type><title>Intensity-modulated radiotherapy of breast cancer using direct aperture optimization</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>van Asselen, Bram ; Schwarz, Marco ; van Vliet-Vroegindeweij, Corine ; Lebesque, Joos V. ; Mijnheer, Ben J. ; Damen, Eugene M.F.</creator><creatorcontrib>van Asselen, Bram ; Schwarz, Marco ; van Vliet-Vroegindeweij, Corine ; Lebesque, Joos V. ; Mijnheer, Ben J. ; Damen, Eugene M.F.</creatorcontrib><description>To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. The DAO technique implemented in the Pinnacle treatment planning system, which is called direct machine parameter optimization (DMPO), was used to generate IMRT plans for twelve breast cancer patients. The prescribed dose was 50 Gy. Two DMPO plans were generated. The first approach uses DMPO only; the second technique combines DMPO with two predefined segments (DMPO segm), having shapes identical to the conventional tangential fields. The weight of these predefined segments is optimized simultaneously with DMPO. The DMPO plans were compared with normal two-step (TS) IMRT, creating segments after optimizing the intensity. Dose homogeneity within the target volume was 4.8±0.6, 4.3±0.5 and 3.8±0.5 Gy for the TS, DMPO and DMPO segm plans, respectively. Comparing the IMRT plans with an idealized dose distribution obtained using only beamlet optimization, the degradation of the dose distribution was less for the DMPO plans compared with the two-step IMRT approach. Furthermore, this degradation was similar for all patients, while for the two-step IMRT approach it was patient specific. An efficient step-and-shoot IMRT solution was developed for the treatment of breast cancer using DMPO combined with two predefined segments.</description><identifier>ISSN: 0167-8140</identifier><identifier>EISSN: 1879-0887</identifier><identifier>DOI: 10.1016/j.radonc.2006.04.010</identifier><identifier>PMID: 16712992</identifier><language>eng</language><publisher>Ireland: Elsevier Ireland Ltd</publisher><subject>Algorithms ; Breast ; Breast Neoplasms - radiotherapy ; Direct aperture optimisation ; Humans ; IMRT ; Radiotherapy Dosage ; Radiotherapy, Intensity-Modulated - instrumentation ; Radiotherapy, Intensity-Modulated - methods ; Step-and-shoot</subject><ispartof>Radiotherapy and oncology, 2006-05, Vol.79 (2), p.162-169</ispartof><rights>2006 Elsevier Ireland Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293</citedby><cites>FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16712992$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>van Asselen, Bram</creatorcontrib><creatorcontrib>Schwarz, Marco</creatorcontrib><creatorcontrib>van Vliet-Vroegindeweij, Corine</creatorcontrib><creatorcontrib>Lebesque, Joos V.</creatorcontrib><creatorcontrib>Mijnheer, Ben J.</creatorcontrib><creatorcontrib>Damen, Eugene M.F.</creatorcontrib><title>Intensity-modulated radiotherapy of breast cancer using direct aperture optimization</title><title>Radiotherapy and oncology</title><addtitle>Radiother Oncol</addtitle><description>To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. The DAO technique implemented in the Pinnacle treatment planning system, which is called direct machine parameter optimization (DMPO), was used to generate IMRT plans for twelve breast cancer patients. The prescribed dose was 50 Gy. Two DMPO plans were generated. The first approach uses DMPO only; the second technique combines DMPO with two predefined segments (DMPO segm), having shapes identical to the conventional tangential fields. The weight of these predefined segments is optimized simultaneously with DMPO. The DMPO plans were compared with normal two-step (TS) IMRT, creating segments after optimizing the intensity. Dose homogeneity within the target volume was 4.8±0.6, 4.3±0.5 and 3.8±0.5 Gy for the TS, DMPO and DMPO segm plans, respectively. Comparing the IMRT plans with an idealized dose distribution obtained using only beamlet optimization, the degradation of the dose distribution was less for the DMPO plans compared with the two-step IMRT approach. Furthermore, this degradation was similar for all patients, while for the two-step IMRT approach it was patient specific. An efficient step-and-shoot IMRT solution was developed for the treatment of breast cancer using DMPO combined with two predefined segments.</description><subject>Algorithms</subject><subject>Breast</subject><subject>Breast Neoplasms - radiotherapy</subject><subject>Direct aperture optimisation</subject><subject>Humans</subject><subject>IMRT</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy, Intensity-Modulated - instrumentation</subject><subject>Radiotherapy, Intensity-Modulated - methods</subject><subject>Step-and-shoot</subject><issn>0167-8140</issn><issn>1879-0887</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kMFq3DAQhkVoSTZp3iAUn3qzM5K1lnUJhJC2gUAv6VnI0ijRsrZcSQ5snj4KXsitp4Hh-_9hPkKuKDQUaHe9a6K2YTINA-ga4A1QOCEb2gtZQ9-LL2RTMFH3lMMZOU9pBwAMWnFKzsqeMinZhjw9TBmn5POhHoNd9jqjrUqxD_kFo54PVXDVEFGnXBk9GYzVkvz0XFkf0eRKzxjzErEKc_ajf9PZh-kb-er0PuHlcV6Qvz_vn-5-149_fj3c3T7Wpu0g18ihdVxQq53YMiu2tBvosBUCLHSgrRADb53opTNbzV3PrOy4dMj1IDUy2V6QH2vvHMO_BVNWo08G93s9YViS6nqQjPVdAfkKmhhSiujUHP2o40FRUB821U6tNtWHTQVcFZsl9v3Yvwwj2s_QUV8BblYAy5evHqNKxmOxtNpRNvj_X3gHWwSJew</recordid><startdate>20060501</startdate><enddate>20060501</enddate><creator>van Asselen, Bram</creator><creator>Schwarz, Marco</creator><creator>van Vliet-Vroegindeweij, Corine</creator><creator>Lebesque, Joos V.</creator><creator>Mijnheer, Ben J.</creator><creator>Damen, Eugene M.F.</creator><general>Elsevier Ireland Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060501</creationdate><title>Intensity-modulated radiotherapy of breast cancer using direct aperture optimization</title><author>van Asselen, Bram ; Schwarz, Marco ; van Vliet-Vroegindeweij, Corine ; Lebesque, Joos V. ; Mijnheer, Ben J. ; Damen, Eugene M.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Algorithms</topic><topic>Breast</topic><topic>Breast Neoplasms - radiotherapy</topic><topic>Direct aperture optimisation</topic><topic>Humans</topic><topic>IMRT</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy, Intensity-Modulated - instrumentation</topic><topic>Radiotherapy, Intensity-Modulated - methods</topic><topic>Step-and-shoot</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>van Asselen, Bram</creatorcontrib><creatorcontrib>Schwarz, Marco</creatorcontrib><creatorcontrib>van Vliet-Vroegindeweij, Corine</creatorcontrib><creatorcontrib>Lebesque, Joos V.</creatorcontrib><creatorcontrib>Mijnheer, Ben J.</creatorcontrib><creatorcontrib>Damen, Eugene M.F.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiotherapy and oncology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>van Asselen, Bram</au><au>Schwarz, Marco</au><au>van Vliet-Vroegindeweij, Corine</au><au>Lebesque, Joos V.</au><au>Mijnheer, Ben J.</au><au>Damen, Eugene M.F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Intensity-modulated radiotherapy of breast cancer using direct aperture optimization</atitle><jtitle>Radiotherapy and oncology</jtitle><addtitle>Radiother Oncol</addtitle><date>2006-05-01</date><risdate>2006</risdate><volume>79</volume><issue>2</issue><spage>162</spage><epage>169</epage><pages>162-169</pages><issn>0167-8140</issn><eissn>1879-0887</eissn><abstract>To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. The DAO technique implemented in the Pinnacle treatment planning system, which is called direct machine parameter optimization (DMPO), was used to generate IMRT plans for twelve breast cancer patients. The prescribed dose was 50 Gy. Two DMPO plans were generated. The first approach uses DMPO only; the second technique combines DMPO with two predefined segments (DMPO segm), having shapes identical to the conventional tangential fields. The weight of these predefined segments is optimized simultaneously with DMPO. The DMPO plans were compared with normal two-step (TS) IMRT, creating segments after optimizing the intensity. Dose homogeneity within the target volume was 4.8±0.6, 4.3±0.5 and 3.8±0.5 Gy for the TS, DMPO and DMPO segm plans, respectively. Comparing the IMRT plans with an idealized dose distribution obtained using only beamlet optimization, the degradation of the dose distribution was less for the DMPO plans compared with the two-step IMRT approach. Furthermore, this degradation was similar for all patients, while for the two-step IMRT approach it was patient specific. An efficient step-and-shoot IMRT solution was developed for the treatment of breast cancer using DMPO combined with two predefined segments.</abstract><cop>Ireland</cop><pub>Elsevier Ireland Ltd</pub><pmid>16712992</pmid><doi>10.1016/j.radonc.2006.04.010</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0167-8140
ispartof Radiotherapy and oncology, 2006-05, Vol.79 (2), p.162-169
issn 0167-8140
1879-0887
language eng
recordid cdi_proquest_miscellaneous_68092286
source ScienceDirect Freedom Collection 2022-2024
subjects Algorithms
Breast
Breast Neoplasms - radiotherapy
Direct aperture optimisation
Humans
IMRT
Radiotherapy Dosage
Radiotherapy, Intensity-Modulated - instrumentation
Radiotherapy, Intensity-Modulated - methods
Step-and-shoot
title Intensity-modulated radiotherapy of breast cancer using direct aperture optimization
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T08%3A19%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Intensity-modulated%20radiotherapy%20of%20breast%20cancer%20using%20direct%20aperture%20optimization&rft.jtitle=Radiotherapy%20and%20oncology&rft.au=van%20Asselen,%20Bram&rft.date=2006-05-01&rft.volume=79&rft.issue=2&rft.spage=162&rft.epage=169&rft.pages=162-169&rft.issn=0167-8140&rft.eissn=1879-0887&rft_id=info:doi/10.1016/j.radonc.2006.04.010&rft_dat=%3Cproquest_cross%3E68092286%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c360t-e403f471daf752d7516b1b5770d060ad77b43f789fc5a4f82d9649fe4ab9ae293%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68092286&rft_id=info:pmid/16712992&rfr_iscdi=true