Loading…

Potential benefit of transesophageal defibrillation: an experimental evaluation

Because of the proximity of the esophagus to the heart, transesophageal defibrillation might increase defibrillation success. We assessed the defibrillation threshold (DFT) of transesophageal defibrillation compared with standard transthoracic defibrillation. Defibrillation success and DFTs were det...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of emergency medicine 2006-07, Vol.24 (4), p.418-422
Main Authors: Mischke, Karl, Schimpf, Thomas, Knackstedt, Christian, Zarse, Markus, Eickholt, Christian, Plisiene, Jurgita, Frechen, Dirk, Gramley, Felix, Schauerte, Patrick
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Because of the proximity of the esophagus to the heart, transesophageal defibrillation might increase defibrillation success. We assessed the defibrillation threshold (DFT) of transesophageal defibrillation compared with standard transthoracic defibrillation. Defibrillation success and DFTs were determined in 22 female pigs with high (68 ± 4 kg, n = 12) or low body weight (39 ± 1 kg, n = 10). After induction of ventricular fibrillation, biphasic shocks were delivered between two cutaneous patch electrodes (sternal and apical position) or between an esophageal and two cutaneous patch electrodes in a sternal and apical position. The esophageal electrode was integrated into a latex sheath covering a standard transesophageal echocardiography probe. In 5 of 12 pigs with high body weight, external defibrillation failed despite 3 consecutive 200-J shocks, whereas subsequent transesophageal defibrillation was successful with the first shock. In the remaining 7 pigs, a more than 50% reduction in DFT was obtained with transesophageal defibrillation compared with standard biphasic external defibrillation (67 ± 27 vs 164 ± 23 J, P < .001). Pigs with lower body weight were successfully defibrillated by both transthoracic and transesophageal shocks. The DFT in pigs with low body weight was significantly lower using transesophageal defibrillation compared with transthoracic shocks (65 ± 15 vs 99 ± 38 J, P < .05). In this animal model, nonresponders to standard external defibrillation could successfully be defibrillated via an esophageal-cutaneous electrode configuration. Overall, an almost 50% DFT reduction was achieved by transesophageal defibrillation. Transesophageal defibrillation may provide an additional tool for terminating VF, which is refractory to external defibrillation, eg, in patients with very high body weight.
ISSN:0735-6757
1532-8171
DOI:10.1016/j.ajem.2005.12.014