The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless d...
Saved in:
Published in: | Haemophilia : the official journal of the World Federation of Hemophilia 2007-09, Vol.13 (5), p.470-472 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c2969-66feae63009b9430bedf5bc6b1032b700e1d9d5594d033bc08417288d2374fcb3 |
container_end_page | 472 |
container_issue | 5 |
container_start_page | 470 |
container_title | Haemophilia : the official journal of the World Federation of Hemophilia |
container_volume | 13 |
creator | BIDLINGMAIER, C. KURNIK, K. HÖLSCHER, G. KAPPLER, M. |
description | The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless device for reconstitution of antihaemophilic factor for non‐haemophilia experts and to define evidence of the need for coaching these physicians via providing two additional photographs illustrating the two key points of the factor reconstitution process. Twenty‐eight physicians of a tertiary care university children's hospital were randomized into two groups, either with no further explanation of the reconstitution device or with two additional photographs, showing the two key steps of the procedure. Reconstitution of dummy‐factor concentrate was video‐taped and evaluated by a blinded helper. Main outcome measure was the successful reconstitution of dummy‐factor concentrate and procedure failure respectively. Of the group without explanation of the reconstitution device, only two of 14 physicians were able to reconstitute the dummy‐factor concentrate. Of the group receiving two photographs, nine of 14 completed the task successfully (P = 0.0068). The needleless device is not self explaining to non‐haemophilia physicians involved in emergency services. Coaching via short to the point instructions as provided by simple visual educational material therefore is crucial to enable these physicians to resolve the expensive emergency drug quickly and correctly. Companies concerned with the production of any devices to dissolve drugs, especially for treatment of rare diseases as haemophilia, therefore should take measures to simplify therapy. |
doi_str_mv | 10.1111/j.1365-2516.2007.01439.x |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68296338</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20723013</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2969-66feae63009b9430bedf5bc6b1032b700e1d9d5594d033bc08417288d2374fcb3</originalsourceid><addsrcrecordid>eNqNkdtu1DAQhi1ERUvhFZCvEFwk-JA4CRIXZRu6rapFQhyk3liOPWG95ETslF0egyfG6a7aS_CNRzP_NzP2jxCmJKbhvNnElIs0YikVMSMkiwlNeBFvH6GT-8LjOU5plDMqjtFT5zaEUM6IeIKOaZbnJOH0BP35BLrvnLd-8rb7jmulfT_ikNPQ-VF5cG_xOdS2m6vlrTUQKriv8aJXej0nV30XldsBRu_wq_Py6-WifI1th9cK2n5Y28YqHGGFh7F3A2hvbwGPqjN9a3-DwTUoZ6ug8jvs_GR2z9BRrRoHzw_3Kfryofy8WEbXHy8uF2fXkWaFKCIhAgmCE1JURcJJBaZOKy0qSjirMkKAmsKkaZEYwnmlSZ7QjOW5YTxLal3xU_Ry3zcs9nMC52VrnYamUR30k5MiD3M4z_8pZCRjPPxtEOZ7oQ5PdSPUchhtq8adpETOxsmNnP2Rsz9yNk7eGSe3AX1xmDFVLZgH8OBUELzbC37ZBnb_3Vguz8o5Cny0563zsL3n1fhDioxnqfy2upD8RqQ371dLecX_AuZptzo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20723013</pqid></control><display><type>article</type><title>Reconstituting factor concentrates: Defining Evidence of Coaching Non-Experts (DEVICE) in haemophilia - a prospective randomized feasibility study</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>BIDLINGMAIER, C. ; KURNIK, K. ; HÖLSCHER, G. ; KAPPLER, M.</creator><creatorcontrib>BIDLINGMAIER, C. ; KURNIK, K. ; HÖLSCHER, G. ; KAPPLER, M.</creatorcontrib><description>The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless device for reconstitution of antihaemophilic factor for non‐haemophilia experts and to define evidence of the need for coaching these physicians via providing two additional photographs illustrating the two key points of the factor reconstitution process. Twenty‐eight physicians of a tertiary care university children's hospital were randomized into two groups, either with no further explanation of the reconstitution device or with two additional photographs, showing the two key steps of the procedure. Reconstitution of dummy‐factor concentrate was video‐taped and evaluated by a blinded helper. Main outcome measure was the successful reconstitution of dummy‐factor concentrate and procedure failure respectively. Of the group without explanation of the reconstitution device, only two of 14 physicians were able to reconstitute the dummy‐factor concentrate. Of the group receiving two photographs, nine of 14 completed the task successfully (P = 0.0068). The needleless device is not self explaining to non‐haemophilia physicians involved in emergency services. Coaching via short to the point instructions as provided by simple visual educational material therefore is crucial to enable these physicians to resolve the expensive emergency drug quickly and correctly. Companies concerned with the production of any devices to dissolve drugs, especially for treatment of rare diseases as haemophilia, therefore should take measures to simplify therapy.</description><identifier>ISSN: 1351-8216</identifier><identifier>EISSN: 1365-2516</identifier><identifier>DOI: 10.1111/j.1365-2516.2007.01439.x</identifier><identifier>PMID: 17880431</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Child ; Coagulants - administration & dosage ; Drug Administration Routes ; Education, Medical, Continuing ; Emergency Medicine - education ; Equipment and Supplies - standards ; factor concentrates ; Factor VIII - administration & dosage ; feasibility ; Feasibility Studies ; haemophilia ; Hemophilia A - drug therapy ; Humans ; Medical Staff, Hospital - education ; needleless device ; Prospective Studies ; reconstitution device</subject><ispartof>Haemophilia : the official journal of the World Federation of Hemophilia, 2007-09, Vol.13 (5), p.470-472</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2969-66feae63009b9430bedf5bc6b1032b700e1d9d5594d033bc08417288d2374fcb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17880431$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>BIDLINGMAIER, C.</creatorcontrib><creatorcontrib>KURNIK, K.</creatorcontrib><creatorcontrib>HÖLSCHER, G.</creatorcontrib><creatorcontrib>KAPPLER, M.</creatorcontrib><title>Reconstituting factor concentrates: Defining Evidence of Coaching Non-Experts (DEVICE) in haemophilia - a prospective randomized feasibility study</title><title>Haemophilia : the official journal of the World Federation of Hemophilia</title><addtitle>Haemophilia</addtitle><description>The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless device for reconstitution of antihaemophilic factor for non‐haemophilia experts and to define evidence of the need for coaching these physicians via providing two additional photographs illustrating the two key points of the factor reconstitution process. Twenty‐eight physicians of a tertiary care university children's hospital were randomized into two groups, either with no further explanation of the reconstitution device or with two additional photographs, showing the two key steps of the procedure. Reconstitution of dummy‐factor concentrate was video‐taped and evaluated by a blinded helper. Main outcome measure was the successful reconstitution of dummy‐factor concentrate and procedure failure respectively. Of the group without explanation of the reconstitution device, only two of 14 physicians were able to reconstitute the dummy‐factor concentrate. Of the group receiving two photographs, nine of 14 completed the task successfully (P = 0.0068). The needleless device is not self explaining to non‐haemophilia physicians involved in emergency services. Coaching via short to the point instructions as provided by simple visual educational material therefore is crucial to enable these physicians to resolve the expensive emergency drug quickly and correctly. Companies concerned with the production of any devices to dissolve drugs, especially for treatment of rare diseases as haemophilia, therefore should take measures to simplify therapy.</description><subject>Child</subject><subject>Coagulants - administration & dosage</subject><subject>Drug Administration Routes</subject><subject>Education, Medical, Continuing</subject><subject>Emergency Medicine - education</subject><subject>Equipment and Supplies - standards</subject><subject>factor concentrates</subject><subject>Factor VIII - administration & dosage</subject><subject>feasibility</subject><subject>Feasibility Studies</subject><subject>haemophilia</subject><subject>Hemophilia A - drug therapy</subject><subject>Humans</subject><subject>Medical Staff, Hospital - education</subject><subject>needleless device</subject><subject>Prospective Studies</subject><subject>reconstitution device</subject><issn>1351-8216</issn><issn>1365-2516</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqNkdtu1DAQhi1ERUvhFZCvEFwk-JA4CRIXZRu6rapFQhyk3liOPWG95ETslF0egyfG6a7aS_CNRzP_NzP2jxCmJKbhvNnElIs0YikVMSMkiwlNeBFvH6GT-8LjOU5plDMqjtFT5zaEUM6IeIKOaZbnJOH0BP35BLrvnLd-8rb7jmulfT_ikNPQ-VF5cG_xOdS2m6vlrTUQKriv8aJXej0nV30XldsBRu_wq_Py6-WifI1th9cK2n5Y28YqHGGFh7F3A2hvbwGPqjN9a3-DwTUoZ6ug8jvs_GR2z9BRrRoHzw_3Kfryofy8WEbXHy8uF2fXkWaFKCIhAgmCE1JURcJJBaZOKy0qSjirMkKAmsKkaZEYwnmlSZ7QjOW5YTxLal3xU_Ry3zcs9nMC52VrnYamUR30k5MiD3M4z_8pZCRjPPxtEOZ7oQ5PdSPUchhtq8adpETOxsmNnP2Rsz9yNk7eGSe3AX1xmDFVLZgH8OBUELzbC37ZBnb_3Vguz8o5Cny0563zsL3n1fhDioxnqfy2upD8RqQ371dLecX_AuZptzo</recordid><startdate>200709</startdate><enddate>200709</enddate><creator>BIDLINGMAIER, C.</creator><creator>KURNIK, K.</creator><creator>HÖLSCHER, G.</creator><creator>KAPPLER, M.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope><scope>7X8</scope></search><sort><creationdate>200709</creationdate><title>Reconstituting factor concentrates: Defining Evidence of Coaching Non-Experts (DEVICE) in haemophilia - a prospective randomized feasibility study</title><author>BIDLINGMAIER, C. ; KURNIK, K. ; HÖLSCHER, G. ; KAPPLER, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2969-66feae63009b9430bedf5bc6b1032b700e1d9d5594d033bc08417288d2374fcb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Child</topic><topic>Coagulants - administration & dosage</topic><topic>Drug Administration Routes</topic><topic>Education, Medical, Continuing</topic><topic>Emergency Medicine - education</topic><topic>Equipment and Supplies - standards</topic><topic>factor concentrates</topic><topic>Factor VIII - administration & dosage</topic><topic>feasibility</topic><topic>Feasibility Studies</topic><topic>haemophilia</topic><topic>Hemophilia A - drug therapy</topic><topic>Humans</topic><topic>Medical Staff, Hospital - education</topic><topic>needleless device</topic><topic>Prospective Studies</topic><topic>reconstitution device</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BIDLINGMAIER, C.</creatorcontrib><creatorcontrib>KURNIK, K.</creatorcontrib><creatorcontrib>HÖLSCHER, G.</creatorcontrib><creatorcontrib>KAPPLER, M.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><collection>MEDLINE - Academic</collection><jtitle>Haemophilia : the official journal of the World Federation of Hemophilia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BIDLINGMAIER, C.</au><au>KURNIK, K.</au><au>HÖLSCHER, G.</au><au>KAPPLER, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reconstituting factor concentrates: Defining Evidence of Coaching Non-Experts (DEVICE) in haemophilia - a prospective randomized feasibility study</atitle><jtitle>Haemophilia : the official journal of the World Federation of Hemophilia</jtitle><addtitle>Haemophilia</addtitle><date>2007-09</date><risdate>2007</risdate><volume>13</volume><issue>5</issue><spage>470</spage><epage>472</epage><pages>470-472</pages><issn>1351-8216</issn><eissn>1365-2516</eissn><abstract>The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless device for reconstitution of antihaemophilic factor for non‐haemophilia experts and to define evidence of the need for coaching these physicians via providing two additional photographs illustrating the two key points of the factor reconstitution process. Twenty‐eight physicians of a tertiary care university children's hospital were randomized into two groups, either with no further explanation of the reconstitution device or with two additional photographs, showing the two key steps of the procedure. Reconstitution of dummy‐factor concentrate was video‐taped and evaluated by a blinded helper. Main outcome measure was the successful reconstitution of dummy‐factor concentrate and procedure failure respectively. Of the group without explanation of the reconstitution device, only two of 14 physicians were able to reconstitute the dummy‐factor concentrate. Of the group receiving two photographs, nine of 14 completed the task successfully (P = 0.0068). The needleless device is not self explaining to non‐haemophilia physicians involved in emergency services. Coaching via short to the point instructions as provided by simple visual educational material therefore is crucial to enable these physicians to resolve the expensive emergency drug quickly and correctly. Companies concerned with the production of any devices to dissolve drugs, especially for treatment of rare diseases as haemophilia, therefore should take measures to simplify therapy.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>17880431</pmid><doi>10.1111/j.1365-2516.2007.01439.x</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1351-8216 |
ispartof | Haemophilia : the official journal of the World Federation of Hemophilia, 2007-09, Vol.13 (5), p.470-472 |
issn | 1351-8216 1365-2516 |
language | eng |
recordid | cdi_proquest_miscellaneous_68296338 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Child Coagulants - administration & dosage Drug Administration Routes Education, Medical, Continuing Emergency Medicine - education Equipment and Supplies - standards factor concentrates Factor VIII - administration & dosage feasibility Feasibility Studies haemophilia Hemophilia A - drug therapy Humans Medical Staff, Hospital - education needleless device Prospective Studies reconstitution device |
title | Reconstituting factor concentrates: Defining Evidence of Coaching Non-Experts (DEVICE) in haemophilia - a prospective randomized feasibility study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T18%3A57%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reconstituting%20factor%20concentrates:%20Defining%20Evidence%20of%20Coaching%20Non-Experts%20(DEVICE)%20in%20haemophilia%20-%20a%20prospective%20randomized%20feasibility%20study&rft.jtitle=Haemophilia%20:%20the%20official%20journal%20of%20the%20World%20Federation%20of%20Hemophilia&rft.au=BIDLINGMAIER,%20C.&rft.date=2007-09&rft.volume=13&rft.issue=5&rft.spage=470&rft.epage=472&rft.pages=470-472&rft.issn=1351-8216&rft.eissn=1365-2516&rft_id=info:doi/10.1111/j.1365-2516.2007.01439.x&rft_dat=%3Cproquest_cross%3E20723013%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2969-66feae63009b9430bedf5bc6b1032b700e1d9d5594d033bc08417288d2374fcb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20723013&rft_id=info:pmid/17880431&rfr_iscdi=true |