Loading…

Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry

A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas–liquid separation cell wit...

Full description

Saved in:
Bibliographic Details
Published in:Analytica chimica acta 2006-07, Vol.573, p.399-405
Main Authors: Leal, L.O., Elsholz, O., Forteza, R., Cerdà, V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203
cites cdi_FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203
container_end_page 405
container_issue
container_start_page 399
container_title Analytica chimica acta
container_volume 573
creator Leal, L.O.
Elsholz, O.
Forteza, R.
Cerdà, V.
description A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas–liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas–liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50–5000 ng L −1. The detection limit (3 σ b/ S) achieved is 5 ng L −1. The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L −1 Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.
doi_str_mv 10.1016/j.aca.2006.04.078
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68348229</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267006009111</els_id><sourcerecordid>68348229</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203</originalsourceid><addsrcrecordid>eNp9kEuLFDEUhYMoTjv6A9xIVu6qTFJ5VONKZnzBgBtdhyR1o2kqlTJJzVD_3ozd4M7V5cB3DtwPodeU9JRQ-e7UG2d6RojsCe-JGp-gAx3V0PGB8afoQAgZOiYVuUIvSjm1yCjhz9EVVYoNQrADirdQIcewmBrSgpPHEbLb8o7tjuM211D2HJafgP2cHnBYTuD-kmUvFSJ-CPUXdmmeunuzpoxNTTE4bGxJeT2Da2vkFKHm_SV65s1c4NXlXqMfnz5-v_nS3X37_PXmw13nBkFr5yxV0loyislSSsgkJTVHIzj1kgshvBmNV4x768XEqJmOQoGw_kiUBM7IcI3ennfXnH5vUKqOoTiYZ7NA2oqW48BHxo4NpGfQ5VRKBq_XHKLJu6ZEPzrWJ90c60fHmnDdHLfOm8v4ZiNM_xoXqQ14fwagvXgfIOviAiwOppCbCz2l8J_5P8eLj0E</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68348229</pqid></control><display><type>article</type><title>Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry</title><source>ScienceDirect Freedom Collection</source><creator>Leal, L.O. ; Elsholz, O. ; Forteza, R. ; Cerdà, V.</creator><creatorcontrib>Leal, L.O. ; Elsholz, O. ; Forteza, R. ; Cerdà, V.</creatorcontrib><description>A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas–liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas–liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50–5000 ng L −1. The detection limit (3 σ b/ S) achieved is 5 ng L −1. The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L −1 Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2006.04.078</identifier><identifier>PMID: 17723552</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Atomic absorption ; Cold-vapor ; Mercury ; Multisyringe flow injection analysis (MSFIA)</subject><ispartof>Analytica chimica acta, 2006-07, Vol.573, p.399-405</ispartof><rights>2006 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203</citedby><cites>FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17723552$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Leal, L.O.</creatorcontrib><creatorcontrib>Elsholz, O.</creatorcontrib><creatorcontrib>Forteza, R.</creatorcontrib><creatorcontrib>Cerdà, V.</creatorcontrib><title>Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas–liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas–liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50–5000 ng L −1. The detection limit (3 σ b/ S) achieved is 5 ng L −1. The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L −1 Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.</description><subject>Atomic absorption</subject><subject>Cold-vapor</subject><subject>Mercury</subject><subject>Multisyringe flow injection analysis (MSFIA)</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kEuLFDEUhYMoTjv6A9xIVu6qTFJ5VONKZnzBgBtdhyR1o2kqlTJJzVD_3ozd4M7V5cB3DtwPodeU9JRQ-e7UG2d6RojsCe-JGp-gAx3V0PGB8afoQAgZOiYVuUIvSjm1yCjhz9EVVYoNQrADirdQIcewmBrSgpPHEbLb8o7tjuM211D2HJafgP2cHnBYTuD-kmUvFSJ-CPUXdmmeunuzpoxNTTE4bGxJeT2Da2vkFKHm_SV65s1c4NXlXqMfnz5-v_nS3X37_PXmw13nBkFr5yxV0loyislSSsgkJTVHIzj1kgshvBmNV4x768XEqJmOQoGw_kiUBM7IcI3ennfXnH5vUKqOoTiYZ7NA2oqW48BHxo4NpGfQ5VRKBq_XHKLJu6ZEPzrWJ90c60fHmnDdHLfOm8v4ZiNM_xoXqQ14fwagvXgfIOviAiwOppCbCz2l8J_5P8eLj0E</recordid><startdate>20060728</startdate><enddate>20060728</enddate><creator>Leal, L.O.</creator><creator>Elsholz, O.</creator><creator>Forteza, R.</creator><creator>Cerdà, V.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060728</creationdate><title>Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry</title><author>Leal, L.O. ; Elsholz, O. ; Forteza, R. ; Cerdà, V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Atomic absorption</topic><topic>Cold-vapor</topic><topic>Mercury</topic><topic>Multisyringe flow injection analysis (MSFIA)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leal, L.O.</creatorcontrib><creatorcontrib>Elsholz, O.</creatorcontrib><creatorcontrib>Forteza, R.</creatorcontrib><creatorcontrib>Cerdà, V.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leal, L.O.</au><au>Elsholz, O.</au><au>Forteza, R.</au><au>Cerdà, V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2006-07-28</date><risdate>2006</risdate><volume>573</volume><spage>399</spage><epage>405</epage><pages>399-405</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas–liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas–liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50–5000 ng L −1. The detection limit (3 σ b/ S) achieved is 5 ng L −1. The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L −1 Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>17723552</pmid><doi>10.1016/j.aca.2006.04.078</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2006-07, Vol.573, p.399-405
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_68348229
source ScienceDirect Freedom Collection
subjects Atomic absorption
Cold-vapor
Mercury
Multisyringe flow injection analysis (MSFIA)
title Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T01%3A16%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20mercury%20by%20multisyringe%20flow%20injection%20system%20with%20cold-vapor%20atomic%20absorption%20spectrometry&rft.jtitle=Analytica%20chimica%20acta&rft.au=Leal,%20L.O.&rft.date=2006-07-28&rft.volume=573&rft.spage=399&rft.epage=405&rft.pages=399-405&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/j.aca.2006.04.078&rft_dat=%3Cproquest_cross%3E68348229%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c351t-cb176bb085db1100d661a9a541f64555fa8af724fbf5d21ad957e5bf9076e4203%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68348229&rft_id=info:pmid/17723552&rfr_iscdi=true