Loading…
Measuring quaternary ammonium cleaning agents with ion selective electrodes
Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenybor...
Saved in:
Published in: | Analytica chimica acta 2006-06, Vol.570 (2), p.186-194 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73 |
---|---|
cites | cdi_FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73 |
container_end_page | 194 |
container_issue | 2 |
container_start_page | 186 |
container_title | Analytica chimica acta |
container_volume | 570 |
creator | Plesha, Michael A. Van Wie, Bernard J. Mullin, James M. Kidwell, David A. |
description | Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10
−6
M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na
+, K
+, Mg
2+, Ca
2+, and Cu
2+ with selectivity coefficients less than 10
−5.3. The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10
−1.7 to 10
−5.5. Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky–Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K
+, Mg
2+ and Ca
2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present. |
doi_str_mv | 10.1016/j.aca.2006.04.024 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68351676</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267006008166</els_id><sourcerecordid>68351676</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73</originalsourceid><addsrcrecordid>eNp9kE1P3DAQhi0EguXjB_RS5QK3pOOP2Il6qhClCKpe2rM1cWapV4kDdgLqv8fbXak9cfJY88yrmYexDxwqDlx_2lTosBIAugJVgVAHbMUbI0slhTpkKwCQpdAGTthpSpv8FRzUMTvhxggp22bF7r8TpiX68Fg8LzhTDBj_FDiOU_DLWLiBMGyb-EhhTsWrn38XfgpFooHc7F-o-FvEqad0zo7WOCS62L9n7NfXm5_X38qHH7d3118eSicbPpfE27ojU3NUbVv30gi9Vr3p2oa0kQYcx97VKEDU0ClseKcx90A3SnJNRp6xq13uU5yeF0qzHX1yNAwYaFqS1Y2suTY6g3wHujilFGltn6If84GWg90atBubDdqtQQvKZoN55uM-fOlG6v9N7JVl4HIPYHI4rCMG59N_XKOl4NugzzuOsooXT9Em5yk46n3Mxmw_-XfWeAM_OI23</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68351676</pqid></control><display><type>article</type><title>Measuring quaternary ammonium cleaning agents with ion selective electrodes</title><source>Elsevier</source><creator>Plesha, Michael A. ; Van Wie, Bernard J. ; Mullin, James M. ; Kidwell, David A.</creator><creatorcontrib>Plesha, Michael A. ; Van Wie, Bernard J. ; Mullin, James M. ; Kidwell, David A.</creatorcontrib><description>Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10
−6
M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na
+, K
+, Mg
2+, Ca
2+, and Cu
2+ with selectivity coefficients less than 10
−5.3. The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10
−1.7 to 10
−5.5. Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky–Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K
+, Mg
2+ and Ca
2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2006.04.024</identifier><identifier>PMID: 17723398</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemical methods ; Exact sciences and technology ; Ion selective electrode ; Polymeric reference electrode ; Quaternary ammonium ion ; Selectivity ; Surfactant</subject><ispartof>Analytica chimica acta, 2006-06, Vol.570 (2), p.186-194</ispartof><rights>2006 Elsevier B.V.</rights><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73</citedby><cites>FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=17863214$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17723398$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Plesha, Michael A.</creatorcontrib><creatorcontrib>Van Wie, Bernard J.</creatorcontrib><creatorcontrib>Mullin, James M.</creatorcontrib><creatorcontrib>Kidwell, David A.</creatorcontrib><title>Measuring quaternary ammonium cleaning agents with ion selective electrodes</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10
−6
M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na
+, K
+, Mg
2+, Ca
2+, and Cu
2+ with selectivity coefficients less than 10
−5.3. The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10
−1.7 to 10
−5.5. Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky–Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K
+, Mg
2+ and Ca
2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><subject>Ion selective electrode</subject><subject>Polymeric reference electrode</subject><subject>Quaternary ammonium ion</subject><subject>Selectivity</subject><subject>Surfactant</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kE1P3DAQhi0EguXjB_RS5QK3pOOP2Il6qhClCKpe2rM1cWapV4kDdgLqv8fbXak9cfJY88yrmYexDxwqDlx_2lTosBIAugJVgVAHbMUbI0slhTpkKwCQpdAGTthpSpv8FRzUMTvhxggp22bF7r8TpiX68Fg8LzhTDBj_FDiOU_DLWLiBMGyb-EhhTsWrn38XfgpFooHc7F-o-FvEqad0zo7WOCS62L9n7NfXm5_X38qHH7d3118eSicbPpfE27ojU3NUbVv30gi9Vr3p2oa0kQYcx97VKEDU0ClseKcx90A3SnJNRp6xq13uU5yeF0qzHX1yNAwYaFqS1Y2suTY6g3wHujilFGltn6If84GWg90atBubDdqtQQvKZoN55uM-fOlG6v9N7JVl4HIPYHI4rCMG59N_XKOl4NugzzuOsooXT9Em5yk46n3Mxmw_-XfWeAM_OI23</recordid><startdate>20060616</startdate><enddate>20060616</enddate><creator>Plesha, Michael A.</creator><creator>Van Wie, Bernard J.</creator><creator>Mullin, James M.</creator><creator>Kidwell, David A.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060616</creationdate><title>Measuring quaternary ammonium cleaning agents with ion selective electrodes</title><author>Plesha, Michael A. ; Van Wie, Bernard J. ; Mullin, James M. ; Kidwell, David A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><topic>Ion selective electrode</topic><topic>Polymeric reference electrode</topic><topic>Quaternary ammonium ion</topic><topic>Selectivity</topic><topic>Surfactant</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Plesha, Michael A.</creatorcontrib><creatorcontrib>Van Wie, Bernard J.</creatorcontrib><creatorcontrib>Mullin, James M.</creatorcontrib><creatorcontrib>Kidwell, David A.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Plesha, Michael A.</au><au>Van Wie, Bernard J.</au><au>Mullin, James M.</au><au>Kidwell, David A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measuring quaternary ammonium cleaning agents with ion selective electrodes</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2006-06-16</date><risdate>2006</risdate><volume>570</volume><issue>2</issue><spage>186</spage><epage>194</epage><pages>186-194</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10
−6
M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na
+, K
+, Mg
2+, Ca
2+, and Cu
2+ with selectivity coefficients less than 10
−5.3. The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10
−1.7 to 10
−5.5. Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky–Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K
+, Mg
2+ and Ca
2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17723398</pmid><doi>10.1016/j.aca.2006.04.024</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2670 |
ispartof | Analytica chimica acta, 2006-06, Vol.570 (2), p.186-194 |
issn | 0003-2670 1873-4324 |
language | eng |
recordid | cdi_proquest_miscellaneous_68351676 |
source | Elsevier |
subjects | Analytical chemistry Chemistry Electrochemical methods Exact sciences and technology Ion selective electrode Polymeric reference electrode Quaternary ammonium ion Selectivity Surfactant |
title | Measuring quaternary ammonium cleaning agents with ion selective electrodes |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T22%3A37%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measuring%20quaternary%20ammonium%20cleaning%20agents%20with%20ion%20selective%20electrodes&rft.jtitle=Analytica%20chimica%20acta&rft.au=Plesha,%20Michael%20A.&rft.date=2006-06-16&rft.volume=570&rft.issue=2&rft.spage=186&rft.epage=194&rft.pages=186-194&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2006.04.024&rft_dat=%3Cproquest_cross%3E68351676%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c381t-e195be751a4995d3726f4d7b98e67370c1adc5a20250b4a81b6a98e0684316e73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68351676&rft_id=info:pmid/17723398&rfr_iscdi=true |