Loading…

Effect of cyclic loading and environmental aging on the fracture toughness of dental resin composite

Objective The main purpose of this study was (1) to investigate the effects of cyclic loading and environmental aging on three dental resin composites with different filler compositions: a fiber filler, a hybrid filler, and a microfill; and (2) to predict fracture in dental resin composite under mix...

Full description

Saved in:
Bibliographic Details
Published in:Journal of biomedical materials research. Part B, Applied biomaterials Applied biomaterials, 2007-01, Vol.80B (1), p.226-235
Main Authors: Ravindranath, Viswanath, Gosz, Michael, De Santiago, Eduardo, Drummond, James L., Mostovoy, Sheldon
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective The main purpose of this study was (1) to investigate the effects of cyclic loading and environmental aging on three dental resin composites with different filler compositions: a fiber filler, a hybrid filler, and a microfill; and (2) to predict fracture in dental resin composite under mixed‐mode loading conditions. Methods Diametral disk specimens 25 mm in diameter and 2 mm in thickness were used in this study. Two methods were used for generating initial cracks in the specimen. The first method involved machining a 3‐mm notch in the center of the disk specimens, and then the notch tips were sharpened with a 0.2‐mm‐diameter jeweler's saw blade. In the second method for obtaining sharper crack tips, a three‐way wedge was forced into a 3.175‐mm hole drilled in the center of the specimen, resulting in sharp cracks emanating from the notch tips. Cyclic Tests The specimens were aged for 4 months in air, water, artificial saliva, and a 50/50 (by volume) mixture of ethanol and water at room temperature in sealed polyethylene containers. Both unaged and aged specimens (5 specimens for each variable) were subjected to cyclic loading at a frequency of 5 Hz with sinusoidal loads cycling for 1, 1000, and 100,000 cycles at a load level ∼60% of the fracture load for noncycled specimens. Following load cycling, the specimens were tested in compression in a displacement‐controlled loading mode at a loading rate of 1.27 mm/min. Results Test results show that aging in a 50/50 alcohol–water mixture lowered the fracture toughness of dental resin composite, which was further reduced by cyclic loading. Mixed‐mode tests The maximum tensile stress (MTS) criterion was used to predict fracture in dental resin composite under mixed‐mode loading conditions. The loads at failure were used as input into a finite element model. After obtaining the stress field in the specimens by the finite element method, the mixed‐mode stress intensity factors were calculated using an interaction energy integral method. Results Good agreement was obtained between the fracture envelope predicted by the MTS criterion and the experimental fracture toughness data. Hence, it can be concluded that it is only necessary to characterize the mode I fracture toughness to fully characterize the mixed‐mode behavior of the dental resin composites that were considered in the present study. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
ISSN:1552-4973
1552-4981
DOI:10.1002/jbm.b.30588