Loading…

Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method

To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the...

Full description

Saved in:
Bibliographic Details
Published in:Physics in medicine & biology 2007-01, Vol.52 (2), p.515-523
Main Authors: Shimozato, T, Tabushi, K, Kitoh, S, Shiota, Y, Hirayama, C, Suzuki, S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93
cites cdi_FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93
container_end_page 523
container_issue 2
container_start_page 515
container_title Physics in medicine & biology
container_volume 52
creator Shimozato, T
Tabushi, K
Kitoh, S
Shiota, Y
Hirayama, C
Suzuki, S
description To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used the BFGS quasi-Newton method based on a general nonlinear optimization technique for the numerical analysis. The attenuation coefficients, aluminium thicknesses and measured transmission data are necessary inputs for the numerical analysis. The calculated x-ray spectrum shape was smooth in the lower to higher energy regions without any angular components. The x-ray spectrum acquired by the employed method was evaluated by comparing the measurements along the central axis percentage depth dose in a water phantom and by a Monte Carlo simulation code, the electron gamma shower code. The values of the calculated percentage depth doses for a 10x10 cm2 field at a 100 cm source-to-surface distance in a water phantom were obtained using the same geometry settings as those of the water phantom measurement. The differences in the measured and calculated values were less than +/-1.0% for a broad region from the shallow part near the surface to deep parts of up to 25 cm in the water phantom.
doi_str_mv 10.1088/0031-9155/52/2/014
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68407932</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68407932</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93</originalsourceid><addsrcrecordid>eNqNkDtv2zAURokiReI6-QMdCk4BOqjmQ6SpMTGatIDbDHmsBB-XDQvJUkgKif99ZNhohiyd7nK-g4uD0GdKvlGi1IIQTquGCrEQbMEWhNYf0IxySSspJDlCs3_ACfqU819CKFWsPkYndMkIk5zMULcyrRtbU2K_wX3AlOBfD_ilSmaL8wCuJIOhi6WAx3aLDe7AR2da3MYNmISNc9BCMqVPeMxx8weXR8CXV9e3-Gk0OVa_4blM6g7KY-9P0cdg2gxnhztH91ff71Y_qvXN9c_VxbpyfMlLBUqRYAN46wRY5xquHPU8MGpsUK72IDyxXjLRWKeIsD40zklpRC0D8w2fo_O9d0j90wi56C7m6dHWbKAfs5aqJsuGswlke9ClPucEQQ8pdiZtNSV6F1nvGupdQy2YZnqKPI2-HOyjnXK8TQ5VJ6DaA7Ef_k_49T3_ntODD_wVTF6S3w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68407932</pqid></control><display><type>article</type><title>Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Shimozato, T ; Tabushi, K ; Kitoh, S ; Shiota, Y ; Hirayama, C ; Suzuki, S</creator><creatorcontrib>Shimozato, T ; Tabushi, K ; Kitoh, S ; Shiota, Y ; Hirayama, C ; Suzuki, S</creatorcontrib><description>To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used the BFGS quasi-Newton method based on a general nonlinear optimization technique for the numerical analysis. The attenuation coefficients, aluminium thicknesses and measured transmission data are necessary inputs for the numerical analysis. The calculated x-ray spectrum shape was smooth in the lower to higher energy regions without any angular components. The x-ray spectrum acquired by the employed method was evaluated by comparing the measurements along the central axis percentage depth dose in a water phantom and by a Monte Carlo simulation code, the electron gamma shower code. The values of the calculated percentage depth doses for a 10x10 cm2 field at a 100 cm source-to-surface distance in a water phantom were obtained using the same geometry settings as those of the water phantom measurement. The differences in the measured and calculated values were less than +/-1.0% for a broad region from the shallow part near the surface to deep parts of up to 25 cm in the water phantom.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/52/2/014</identifier><identifier>PMID: 17202630</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Aluminum - chemistry ; Humans ; Models, Statistical ; Models, Theoretical ; Monte Carlo Method ; Particle Accelerators ; Phantoms, Imaging ; Photons ; Radiometry ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted - methods ; Water - chemistry ; X-Rays</subject><ispartof>Physics in medicine &amp; biology, 2007-01, Vol.52 (2), p.515-523</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93</citedby><cites>FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17202630$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shimozato, T</creatorcontrib><creatorcontrib>Tabushi, K</creatorcontrib><creatorcontrib>Kitoh, S</creatorcontrib><creatorcontrib>Shiota, Y</creatorcontrib><creatorcontrib>Hirayama, C</creatorcontrib><creatorcontrib>Suzuki, S</creatorcontrib><title>Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method</title><title>Physics in medicine &amp; biology</title><addtitle>Phys Med Biol</addtitle><description>To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used the BFGS quasi-Newton method based on a general nonlinear optimization technique for the numerical analysis. The attenuation coefficients, aluminium thicknesses and measured transmission data are necessary inputs for the numerical analysis. The calculated x-ray spectrum shape was smooth in the lower to higher energy regions without any angular components. The x-ray spectrum acquired by the employed method was evaluated by comparing the measurements along the central axis percentage depth dose in a water phantom and by a Monte Carlo simulation code, the electron gamma shower code. The values of the calculated percentage depth doses for a 10x10 cm2 field at a 100 cm source-to-surface distance in a water phantom were obtained using the same geometry settings as those of the water phantom measurement. The differences in the measured and calculated values were less than +/-1.0% for a broad region from the shallow part near the surface to deep parts of up to 25 cm in the water phantom.</description><subject>Aluminum - chemistry</subject><subject>Humans</subject><subject>Models, Statistical</subject><subject>Models, Theoretical</subject><subject>Monte Carlo Method</subject><subject>Particle Accelerators</subject><subject>Phantoms, Imaging</subject><subject>Photons</subject><subject>Radiometry</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy Planning, Computer-Assisted - methods</subject><subject>Water - chemistry</subject><subject>X-Rays</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqNkDtv2zAURokiReI6-QMdCk4BOqjmQ6SpMTGatIDbDHmsBB-XDQvJUkgKif99ZNhohiyd7nK-g4uD0GdKvlGi1IIQTquGCrEQbMEWhNYf0IxySSspJDlCs3_ACfqU819CKFWsPkYndMkIk5zMULcyrRtbU2K_wX3AlOBfD_ilSmaL8wCuJIOhi6WAx3aLDe7AR2da3MYNmISNc9BCMqVPeMxx8weXR8CXV9e3-Gk0OVa_4blM6g7KY-9P0cdg2gxnhztH91ff71Y_qvXN9c_VxbpyfMlLBUqRYAN46wRY5xquHPU8MGpsUK72IDyxXjLRWKeIsD40zklpRC0D8w2fo_O9d0j90wi56C7m6dHWbKAfs5aqJsuGswlke9ClPucEQQ8pdiZtNSV6F1nvGupdQy2YZnqKPI2-HOyjnXK8TQ5VJ6DaA7Ef_k_49T3_ntODD_wVTF6S3w</recordid><startdate>20070121</startdate><enddate>20070121</enddate><creator>Shimozato, T</creator><creator>Tabushi, K</creator><creator>Kitoh, S</creator><creator>Shiota, Y</creator><creator>Hirayama, C</creator><creator>Suzuki, S</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070121</creationdate><title>Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method</title><author>Shimozato, T ; Tabushi, K ; Kitoh, S ; Shiota, Y ; Hirayama, C ; Suzuki, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Aluminum - chemistry</topic><topic>Humans</topic><topic>Models, Statistical</topic><topic>Models, Theoretical</topic><topic>Monte Carlo Method</topic><topic>Particle Accelerators</topic><topic>Phantoms, Imaging</topic><topic>Photons</topic><topic>Radiometry</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy Planning, Computer-Assisted - methods</topic><topic>Water - chemistry</topic><topic>X-Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shimozato, T</creatorcontrib><creatorcontrib>Tabushi, K</creatorcontrib><creatorcontrib>Kitoh, S</creatorcontrib><creatorcontrib>Shiota, Y</creatorcontrib><creatorcontrib>Hirayama, C</creatorcontrib><creatorcontrib>Suzuki, S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shimozato, T</au><au>Tabushi, K</au><au>Kitoh, S</au><au>Shiota, Y</au><au>Hirayama, C</au><au>Suzuki, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method</atitle><jtitle>Physics in medicine &amp; biology</jtitle><addtitle>Phys Med Biol</addtitle><date>2007-01-21</date><risdate>2007</risdate><volume>52</volume><issue>2</issue><spage>515</spage><epage>523</epage><pages>515-523</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><abstract>To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used the BFGS quasi-Newton method based on a general nonlinear optimization technique for the numerical analysis. The attenuation coefficients, aluminium thicknesses and measured transmission data are necessary inputs for the numerical analysis. The calculated x-ray spectrum shape was smooth in the lower to higher energy regions without any angular components. The x-ray spectrum acquired by the employed method was evaluated by comparing the measurements along the central axis percentage depth dose in a water phantom and by a Monte Carlo simulation code, the electron gamma shower code. The values of the calculated percentage depth doses for a 10x10 cm2 field at a 100 cm source-to-surface distance in a water phantom were obtained using the same geometry settings as those of the water phantom measurement. The differences in the measured and calculated values were less than +/-1.0% for a broad region from the shallow part near the surface to deep parts of up to 25 cm in the water phantom.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>17202630</pmid><doi>10.1088/0031-9155/52/2/014</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2007-01, Vol.52 (2), p.515-523
issn 0031-9155
1361-6560
language eng
recordid cdi_proquest_miscellaneous_68407932
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects Aluminum - chemistry
Humans
Models, Statistical
Models, Theoretical
Monte Carlo Method
Particle Accelerators
Phantoms, Imaging
Photons
Radiometry
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted - methods
Water - chemistry
X-Rays
title Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T17%3A04%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calculation%20of%2010%20MV%20x-ray%20spectra%20emitted%20by%20a%20medical%20linear%20accelerator%20using%20the%20BFGS%20quasi-Newton%20method&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Shimozato,%20T&rft.date=2007-01-21&rft.volume=52&rft.issue=2&rft.spage=515&rft.epage=523&rft.pages=515-523&rft.issn=0031-9155&rft.eissn=1361-6560&rft_id=info:doi/10.1088/0031-9155/52/2/014&rft_dat=%3Cproquest_cross%3E68407932%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c373t-e880fbfedbc5ebcc938c1d3f21abf8c4de5d0bd6259bc805bdf9cc66a546f2d93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68407932&rft_id=info:pmid/17202630&rfr_iscdi=true