Afterdischarges during cortical stimulation at different frequencies and intensities

Summary Purpose The occurrence of unwanted afterdischarges (ADs) impedes cortical stimulation for mapping purposes. We investigated the safety of several stimulation paradigms. Methods We compared the incidence of ADs and behavioral responses of two stimulation frequencies (50 and 100 Hz), at two in...

Full description

Saved in:
Bibliographic Details
Published in:Epilepsy research 2007-10, Vol.77 (1), p.65-69
Main Authors: Motamedi, Gholam K, Okunola, Oladotun, Kalhorn, Christopher G, Mostofi, Navid, Mizuno-Matsumoto, Yuko, Cho, Yong-won, Meador, Kimford J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Purpose The occurrence of unwanted afterdischarges (ADs) impedes cortical stimulation for mapping purposes. We investigated the safety of several stimulation paradigms. Methods We compared the incidence of ADs and behavioral responses of two stimulation frequencies (50 and 100 Hz), at two intensities (1 and 0.2 ms pulse widths). Results Stimulation with 100 Hz was more likely to cause ADs than 50 Hz, and stimulation using 1 ms pulse width was more likely to cause ADs than 0.2 ms. Conclusions Stimulation using 50 Hz frequency with a pulse width of 0.2 ms might be safer during cortical mapping.