Microfluidic logic gates and timers

We use surface tension-based passive pumping and fluidic resistance to create a number of microfluidic analogs to electronic circuit components. Three classes of components are demonstrated: (1) OR/AND, NOR/NAND, and XNOR digital microfluidic logic gates; (2) programmable, autonomous timers; and (3)...

Full description

Saved in:
Bibliographic Details
Published in:Lab on a chip 2007-01, Vol.7 (11), p.1449-1453
Main Authors: Toepke, Michael W, Abhyankar, Vinay V, Beebe, David J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We use surface tension-based passive pumping and fluidic resistance to create a number of microfluidic analogs to electronic circuit components. Three classes of components are demonstrated: (1) OR/AND, NOR/NAND, and XNOR digital microfluidic logic gates; (2) programmable, autonomous timers; and (3) slow, perfusive flow rheostats. The components can be implemented with standard pipettes and provide a means of non-electronic and autonomous preprogrammed control with potential utility in cell studies and high throughput screening applications.