A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction

No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To...

Full description

Saved in:
Bibliographic Details
Published in:Physiological measurement 2005-10, Vol.26 (5), p.823-836
Main Authors: McMahon, B P, Frøkjær, J B, Liao, D, Kunwald, P, Drewes, A M, Gregersen, H
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203
cites cdi_FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203
container_end_page 836
container_issue 5
container_start_page 823
container_title Physiological measurement
container_volume 26
creator McMahon, B P
Frøkjær, J B
Liao, D
Kunwald, P
Drewes, A M
Gregersen, H
description No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To validate the FLIP technique for profiling the OGJ, polymethylmethacrylate (Perspex) cylinders with different CSAs were measured ten times by the FLIP to assess reproducibility and accuracy. A geometric sphincter phantom was constructed and its geometry was measured with a 360 degrees radial ultrasound (US) mini-probe pulled through it at a rate of 1 mm s(-1). The measurements were compared with FLIP measurements. Safety and technique reproducibility were tested on a volunteer. Reproducibility and accuracy between the ten samples were good. The probe performed well with and without a balloon mounted on it except for the smallest CSA (38.5 mm(2)) where there was a difference of 22% from the actual value at one CSA measurement point. The FLIP imaged the phantom geometry as well as the radial scanning US mini-probe. Pilot studies on a volunteer showed that the probe could be placed in the OGJ and the balloon distensions revealed the geometry of the sphincter at various levels of distension. The technique may be useful in accessing the role of the OGJ in diseases such as gastroesophageal reflux disease (GORD) and achalasia and their treatments with surgical and endoscopic therapies.
doi_str_mv 10.1088/0967-3334/26/5/019
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68459420</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68459420</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203</originalsourceid><addsrcrecordid>eNqNkc1u1DAUhS0EokPhBVggr1C7COOf2HHYVVULlUaiC1hbHuc64yoTBzspYtd36LPwQjwJzszQLrrp6i7ud879OQi9p-QTJUotSS2rgnNeLplciiWh9Qu0oFzSQoqqfokWD8ARepPSDSGUKiZeoyMqs55UdIH-nOEefuER7Kb3PyfALkQMt6abzOj7Fqdh43s7QsRuytWHHvse3_pkIZoOh9iaPn3GZhg6b82uHxweN_DAZ6qbtpB1W9POlkMMa8Anl6ur69PduJn-P_JRHyCFYWPa8PfuvjVpjN7im4PnW_TKmS7Bu0M9Rj8uL76ffy1W375cnZ-tCssrPhaudLV0ZcOZI0LWQJWBShorK8lEBdA0Ys2FJMBKZWVthJKspMpxwVT-FOHH6OPeN--cn5NGvZ0v7zrTQ5iSlqoUdbkD2R60MaQUwekh5nvjb02JnsPScxZ6zkIzqYXOYWXRh4P7tN5C8yg5pJOBYg_4MDzP8PQp_5TTQ-P4P0orrjU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68459420</pqid></control><display><type>article</type><title>A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction</title><source>Institute of Physics</source><creator>McMahon, B P ; Frøkjær, J B ; Liao, D ; Kunwald, P ; Drewes, A M ; Gregersen, H</creator><creatorcontrib>McMahon, B P ; Frøkjær, J B ; Liao, D ; Kunwald, P ; Drewes, A M ; Gregersen, H</creatorcontrib><description>No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To validate the FLIP technique for profiling the OGJ, polymethylmethacrylate (Perspex) cylinders with different CSAs were measured ten times by the FLIP to assess reproducibility and accuracy. A geometric sphincter phantom was constructed and its geometry was measured with a 360 degrees radial ultrasound (US) mini-probe pulled through it at a rate of 1 mm s(-1). The measurements were compared with FLIP measurements. Safety and technique reproducibility were tested on a volunteer. Reproducibility and accuracy between the ten samples were good. The probe performed well with and without a balloon mounted on it except for the smallest CSA (38.5 mm(2)) where there was a difference of 22% from the actual value at one CSA measurement point. The FLIP imaged the phantom geometry as well as the radial scanning US mini-probe. Pilot studies on a volunteer showed that the probe could be placed in the OGJ and the balloon distensions revealed the geometry of the sphincter at various levels of distension. The technique may be useful in accessing the role of the OGJ in diseases such as gastroesophageal reflux disease (GORD) and achalasia and their treatments with surgical and endoscopic therapies.</description><identifier>ISSN: 0967-3334</identifier><identifier>EISSN: 1361-6579</identifier><identifier>DOI: 10.1088/0967-3334/26/5/019</identifier><identifier>PMID: 16088071</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Esophageal Sphincter, Lower - physiology ; Esophagogastric Junction - physiology ; Humans</subject><ispartof>Physiological measurement, 2005-10, Vol.26 (5), p.823-836</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203</citedby><cites>FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16088071$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>McMahon, B P</creatorcontrib><creatorcontrib>Frøkjær, J B</creatorcontrib><creatorcontrib>Liao, D</creatorcontrib><creatorcontrib>Kunwald, P</creatorcontrib><creatorcontrib>Drewes, A M</creatorcontrib><creatorcontrib>Gregersen, H</creatorcontrib><title>A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction</title><title>Physiological measurement</title><addtitle>Physiol Meas</addtitle><description>No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To validate the FLIP technique for profiling the OGJ, polymethylmethacrylate (Perspex) cylinders with different CSAs were measured ten times by the FLIP to assess reproducibility and accuracy. A geometric sphincter phantom was constructed and its geometry was measured with a 360 degrees radial ultrasound (US) mini-probe pulled through it at a rate of 1 mm s(-1). The measurements were compared with FLIP measurements. Safety and technique reproducibility were tested on a volunteer. Reproducibility and accuracy between the ten samples were good. The probe performed well with and without a balloon mounted on it except for the smallest CSA (38.5 mm(2)) where there was a difference of 22% from the actual value at one CSA measurement point. The FLIP imaged the phantom geometry as well as the radial scanning US mini-probe. Pilot studies on a volunteer showed that the probe could be placed in the OGJ and the balloon distensions revealed the geometry of the sphincter at various levels of distension. The technique may be useful in accessing the role of the OGJ in diseases such as gastroesophageal reflux disease (GORD) and achalasia and their treatments with surgical and endoscopic therapies.</description><subject>Esophageal Sphincter, Lower - physiology</subject><subject>Esophagogastric Junction - physiology</subject><subject>Humans</subject><issn>0967-3334</issn><issn>1361-6579</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqNkc1u1DAUhS0EokPhBVggr1C7COOf2HHYVVULlUaiC1hbHuc64yoTBzspYtd36LPwQjwJzszQLrrp6i7ud879OQi9p-QTJUotSS2rgnNeLplciiWh9Qu0oFzSQoqqfokWD8ARepPSDSGUKiZeoyMqs55UdIH-nOEefuER7Kb3PyfALkQMt6abzOj7Fqdh43s7QsRuytWHHvse3_pkIZoOh9iaPn3GZhg6b82uHxweN_DAZ6qbtpB1W9POlkMMa8Anl6ur69PduJn-P_JRHyCFYWPa8PfuvjVpjN7im4PnW_TKmS7Bu0M9Rj8uL76ffy1W375cnZ-tCssrPhaudLV0ZcOZI0LWQJWBShorK8lEBdA0Ys2FJMBKZWVthJKspMpxwVT-FOHH6OPeN--cn5NGvZ0v7zrTQ5iSlqoUdbkD2R60MaQUwekh5nvjb02JnsPScxZ6zkIzqYXOYWXRh4P7tN5C8yg5pJOBYg_4MDzP8PQp_5TTQ-P4P0orrjU</recordid><startdate>20051001</startdate><enddate>20051001</enddate><creator>McMahon, B P</creator><creator>Frøkjær, J B</creator><creator>Liao, D</creator><creator>Kunwald, P</creator><creator>Drewes, A M</creator><creator>Gregersen, H</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20051001</creationdate><title>A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction</title><author>McMahon, B P ; Frøkjær, J B ; Liao, D ; Kunwald, P ; Drewes, A M ; Gregersen, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Esophageal Sphincter, Lower - physiology</topic><topic>Esophagogastric Junction - physiology</topic><topic>Humans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>McMahon, B P</creatorcontrib><creatorcontrib>Frøkjær, J B</creatorcontrib><creatorcontrib>Liao, D</creatorcontrib><creatorcontrib>Kunwald, P</creatorcontrib><creatorcontrib>Drewes, A M</creatorcontrib><creatorcontrib>Gregersen, H</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physiological measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>McMahon, B P</au><au>Frøkjær, J B</au><au>Liao, D</au><au>Kunwald, P</au><au>Drewes, A M</au><au>Gregersen, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction</atitle><jtitle>Physiological measurement</jtitle><addtitle>Physiol Meas</addtitle><date>2005-10-01</date><risdate>2005</risdate><volume>26</volume><issue>5</issue><spage>823</spage><epage>836</epage><pages>823-836</pages><issn>0967-3334</issn><eissn>1361-6579</eissn><abstract>No quantitative method has been implemented routinely in clinical practice to assess the oesophago-gastric junction (OGJ). Using impedance planimetry a functional lumen imaging probe (FLIP) was constructed to measure eight cross-sectional areas (CSA) at 4 mm intervals inside a saline-filled bag. To validate the FLIP technique for profiling the OGJ, polymethylmethacrylate (Perspex) cylinders with different CSAs were measured ten times by the FLIP to assess reproducibility and accuracy. A geometric sphincter phantom was constructed and its geometry was measured with a 360 degrees radial ultrasound (US) mini-probe pulled through it at a rate of 1 mm s(-1). The measurements were compared with FLIP measurements. Safety and technique reproducibility were tested on a volunteer. Reproducibility and accuracy between the ten samples were good. The probe performed well with and without a balloon mounted on it except for the smallest CSA (38.5 mm(2)) where there was a difference of 22% from the actual value at one CSA measurement point. The FLIP imaged the phantom geometry as well as the radial scanning US mini-probe. Pilot studies on a volunteer showed that the probe could be placed in the OGJ and the balloon distensions revealed the geometry of the sphincter at various levels of distension. The technique may be useful in accessing the role of the OGJ in diseases such as gastroesophageal reflux disease (GORD) and achalasia and their treatments with surgical and endoscopic therapies.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>16088071</pmid><doi>10.1088/0967-3334/26/5/019</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0967-3334
ispartof Physiological measurement, 2005-10, Vol.26 (5), p.823-836
issn 0967-3334
1361-6579
language eng
recordid cdi_proquest_miscellaneous_68459420
source Institute of Physics
subjects Esophageal Sphincter, Lower - physiology
Esophagogastric Junction - physiology
Humans
title A new technique for evaluating sphincter function in visceral organs: application of the functional lumen imaging probe (FLIP) for the evaluation of the oesophago–gastric junction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T15%3A27%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20technique%20for%20evaluating%20sphincter%20function%20in%20visceral%20organs:%20application%20of%20the%20functional%20lumen%20imaging%20probe%20(FLIP)%20for%20the%20evaluation%20of%20the%20oesophago%E2%80%93gastric%20junction&rft.jtitle=Physiological%20measurement&rft.au=McMahon,%20B%20P&rft.date=2005-10-01&rft.volume=26&rft.issue=5&rft.spage=823&rft.epage=836&rft.pages=823-836&rft.issn=0967-3334&rft.eissn=1361-6579&rft_id=info:doi/10.1088/0967-3334/26/5/019&rft_dat=%3Cproquest_cross%3E68459420%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c373t-f4f96f4d32f0569e18ae76ac676257eedd5b3560e248c69a5862418f352818203%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68459420&rft_id=info:pmid/16088071&rfr_iscdi=true