Loading…
Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components
Polyethylene liner failure of cementless acetabular components has been reported to be the most common complication of current modular cups. We performed a retrospective review of 128 consecutive primary total hip arthroplasties in 111 patients who had a second-generation Harris-Galante cup (Harris-...
Saved in:
Published in: | The Journal of arthroplasty 2005-09, Vol.20 (6), p.717-722 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273 |
---|---|
cites | cdi_FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273 |
container_end_page | 722 |
container_issue | 6 |
container_start_page | 717 |
container_title | The Journal of arthroplasty |
container_volume | 20 |
creator | Min, Byung-Woo Song, Kwang-Soon Kang, Chul-Hyung Won, Ye-Yeon Koo, Kyung-Hoi |
description | Polyethylene liner failure of cementless acetabular components has been reported to be the most common complication of current modular cups. We performed a retrospective review of 128 consecutive primary total hip arthroplasties in 111 patients who had a second-generation Harris-Galante cup (Harris-Galante II, Zimmer, Warsaw, Ind). The mean length of the follow-up period was 8.0 years (range 5-12.9 years), with 26 cups (20.2%) having undergone revision by that time. Twenty-two hips (17.3%) had failure of the polyethylene liner. We found that polyethylene liner failure remains the main cause of revision of this modular cup. The main difference between our population of patients and other populations that have used this cup and liner is our population's cultural inclination toward squatting and leg crossing, body positions that increased the risk of impingement and eccentric wear. |
doi_str_mv | 10.1016/j.arth.2004.11.006 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68553303</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540305000197</els_id><sourcerecordid>68553303</sourcerecordid><originalsourceid>FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273</originalsourceid><addsrcrecordid>eNp9kE1r20AQhpfQELtO_kAORafepMx-SoZegqntgKGFJOdltRqRNfKuu7sq-N9HxobeeprDPO_LzEPII4WKAlVP-8rE_FExAFFRWgGoGzKnkrOyEaC-kDk0DS-lAD4jX1PaA1AqpbgjM6ooX9ZQz8nb7zCcMH-cBvRY7JzHWKyNG8aIhfPFK9rgu3IzLaPJLvhia2J0qdyYwfiMxbPFbNpxMLFYhcMxePQ53ZPb3gwJH65zQd7XP99W23L3a_Oyet6VlkuRS8FaVre1VW1vVIemwUZ2YtkKS1XPqOhbubSiY9DJtgGKkgvGEKFRnGPPar4g3y-9xxj-jJiyPrhkcZhOwzAmrRopOQc-gewC2hhSitjrY3QHE0-agj671Ht9dqnPLjWlenI5hb5d28f2gN2_yFXeBPy4ADj9-Ndh1Mk69BY7F9Fm3QX3v_5PPcaF7g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68553303</pqid></control><display><type>article</type><title>Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components</title><source>Elsevier</source><creator>Min, Byung-Woo ; Song, Kwang-Soon ; Kang, Chul-Hyung ; Won, Ye-Yeon ; Koo, Kyung-Hoi</creator><creatorcontrib>Min, Byung-Woo ; Song, Kwang-Soon ; Kang, Chul-Hyung ; Won, Ye-Yeon ; Koo, Kyung-Hoi</creatorcontrib><description>Polyethylene liner failure of cementless acetabular components has been reported to be the most common complication of current modular cups. We performed a retrospective review of 128 consecutive primary total hip arthroplasties in 111 patients who had a second-generation Harris-Galante cup (Harris-Galante II, Zimmer, Warsaw, Ind). The mean length of the follow-up period was 8.0 years (range 5-12.9 years), with 26 cups (20.2%) having undergone revision by that time. Twenty-two hips (17.3%) had failure of the polyethylene liner. We found that polyethylene liner failure remains the main cause of revision of this modular cup. The main difference between our population of patients and other populations that have used this cup and liner is our population's cultural inclination toward squatting and leg crossing, body positions that increased the risk of impingement and eccentric wear.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2004.11.006</identifier><identifier>PMID: 16139707</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Acetabulum ; Arthroplasty, Replacement, Hip ; Female ; Follow-Up Studies ; Harris-Galante II acetabular cups ; Hip Prosthesis - adverse effects ; Humans ; Male ; Middle Aged ; Polyethylene ; polyethylene liner failure ; Posture ; Prosthesis Failure ; Reoperation ; Retrospective Studies ; total hip arthroplasty</subject><ispartof>The Journal of arthroplasty, 2005-09, Vol.20 (6), p.717-722</ispartof><rights>2005 Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273</citedby><cites>FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16139707$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Min, Byung-Woo</creatorcontrib><creatorcontrib>Song, Kwang-Soon</creatorcontrib><creatorcontrib>Kang, Chul-Hyung</creatorcontrib><creatorcontrib>Won, Ye-Yeon</creatorcontrib><creatorcontrib>Koo, Kyung-Hoi</creatorcontrib><title>Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Polyethylene liner failure of cementless acetabular components has been reported to be the most common complication of current modular cups. We performed a retrospective review of 128 consecutive primary total hip arthroplasties in 111 patients who had a second-generation Harris-Galante cup (Harris-Galante II, Zimmer, Warsaw, Ind). The mean length of the follow-up period was 8.0 years (range 5-12.9 years), with 26 cups (20.2%) having undergone revision by that time. Twenty-two hips (17.3%) had failure of the polyethylene liner. We found that polyethylene liner failure remains the main cause of revision of this modular cup. The main difference between our population of patients and other populations that have used this cup and liner is our population's cultural inclination toward squatting and leg crossing, body positions that increased the risk of impingement and eccentric wear.</description><subject>Acetabulum</subject><subject>Arthroplasty, Replacement, Hip</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Harris-Galante II acetabular cups</subject><subject>Hip Prosthesis - adverse effects</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Polyethylene</subject><subject>polyethylene liner failure</subject><subject>Posture</subject><subject>Prosthesis Failure</subject><subject>Reoperation</subject><subject>Retrospective Studies</subject><subject>total hip arthroplasty</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp9kE1r20AQhpfQELtO_kAORafepMx-SoZegqntgKGFJOdltRqRNfKuu7sq-N9HxobeeprDPO_LzEPII4WKAlVP-8rE_FExAFFRWgGoGzKnkrOyEaC-kDk0DS-lAD4jX1PaA1AqpbgjM6ooX9ZQz8nb7zCcMH-cBvRY7JzHWKyNG8aIhfPFK9rgu3IzLaPJLvhia2J0qdyYwfiMxbPFbNpxMLFYhcMxePQ53ZPb3gwJH65zQd7XP99W23L3a_Oyet6VlkuRS8FaVre1VW1vVIemwUZ2YtkKS1XPqOhbubSiY9DJtgGKkgvGEKFRnGPPar4g3y-9xxj-jJiyPrhkcZhOwzAmrRopOQc-gewC2hhSitjrY3QHE0-agj671Ht9dqnPLjWlenI5hb5d28f2gN2_yFXeBPy4ADj9-Ndh1Mk69BY7F9Fm3QX3v_5PPcaF7g</recordid><startdate>20050901</startdate><enddate>20050901</enddate><creator>Min, Byung-Woo</creator><creator>Song, Kwang-Soon</creator><creator>Kang, Chul-Hyung</creator><creator>Won, Ye-Yeon</creator><creator>Koo, Kyung-Hoi</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050901</creationdate><title>Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components</title><author>Min, Byung-Woo ; Song, Kwang-Soon ; Kang, Chul-Hyung ; Won, Ye-Yeon ; Koo, Kyung-Hoi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Acetabulum</topic><topic>Arthroplasty, Replacement, Hip</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Harris-Galante II acetabular cups</topic><topic>Hip Prosthesis - adverse effects</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Polyethylene</topic><topic>polyethylene liner failure</topic><topic>Posture</topic><topic>Prosthesis Failure</topic><topic>Reoperation</topic><topic>Retrospective Studies</topic><topic>total hip arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Min, Byung-Woo</creatorcontrib><creatorcontrib>Song, Kwang-Soon</creatorcontrib><creatorcontrib>Kang, Chul-Hyung</creatorcontrib><creatorcontrib>Won, Ye-Yeon</creatorcontrib><creatorcontrib>Koo, Kyung-Hoi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Min, Byung-Woo</au><au>Song, Kwang-Soon</au><au>Kang, Chul-Hyung</au><au>Won, Ye-Yeon</au><au>Koo, Kyung-Hoi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2005-09-01</date><risdate>2005</risdate><volume>20</volume><issue>6</issue><spage>717</spage><epage>722</epage><pages>717-722</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Polyethylene liner failure of cementless acetabular components has been reported to be the most common complication of current modular cups. We performed a retrospective review of 128 consecutive primary total hip arthroplasties in 111 patients who had a second-generation Harris-Galante cup (Harris-Galante II, Zimmer, Warsaw, Ind). The mean length of the follow-up period was 8.0 years (range 5-12.9 years), with 26 cups (20.2%) having undergone revision by that time. Twenty-two hips (17.3%) had failure of the polyethylene liner. We found that polyethylene liner failure remains the main cause of revision of this modular cup. The main difference between our population of patients and other populations that have used this cup and liner is our population's cultural inclination toward squatting and leg crossing, body positions that increased the risk of impingement and eccentric wear.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>16139707</pmid><doi>10.1016/j.arth.2004.11.006</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0883-5403 |
ispartof | The Journal of arthroplasty, 2005-09, Vol.20 (6), p.717-722 |
issn | 0883-5403 1532-8406 |
language | eng |
recordid | cdi_proquest_miscellaneous_68553303 |
source | Elsevier |
subjects | Acetabulum Arthroplasty, Replacement, Hip Female Follow-Up Studies Harris-Galante II acetabular cups Hip Prosthesis - adverse effects Humans Male Middle Aged Polyethylene polyethylene liner failure Posture Prosthesis Failure Reoperation Retrospective Studies total hip arthroplasty |
title | Polyethylene Liner Failure in Second-Generation Harris-Galante Acetabular Components |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T01%3A06%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Polyethylene%20Liner%20Failure%20in%20Second-Generation%20Harris-Galante%20Acetabular%20Components&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Min,%20Byung-Woo&rft.date=2005-09-01&rft.volume=20&rft.issue=6&rft.spage=717&rft.epage=722&rft.pages=717-722&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2004.11.006&rft_dat=%3Cproquest_cross%3E68553303%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c354t-42b27b7c6bfa6dea8e85d49b4c16f214fb59c4d20d5b801e53422ee08633ef273%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68553303&rft_id=info:pmid/16139707&rfr_iscdi=true |