Recommended standards for biochemical markers of myocardial damage: All Wales Clinical Biochemistry Audit Group
The effective use of cardiac-specific troponin estimations in the diagnosis of acute myocardial infarction (AMI) is clouded by the imprecise definition surrounding the decision limits. This has led to a wide variation of criteria for the diagnosis of myocardial infarction. A survey of troponin measu...
Saved in:
Published in: | Annals of clinical biochemistry 2005-09, Vol.42 (5), p.346-350 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The effective use of cardiac-specific troponin estimations in the diagnosis of acute myocardial infarction (AMI) is clouded by the imprecise definition surrounding the decision limits. This has led to a wide variation of criteria for the diagnosis of myocardial infarction. A survey of troponin measurements in Welsh laboratories, undertaken in 2003 under the auspices of the All Wales Clinical Biochemistry Audit Group, revealed significant variations in laboratory and clinical practice. Extensive discussion and consultation led by a working group of clinical biochemists and cardiologists in Wales culminated in recommendations concerning the use of troponin assays to establish myocardial damage.
The key recommendations are:
•Cardiac troponin (T or I) should be the first-line test for myocardial damage;
•Two samples should be collected, at admission and 12-24 h later. The first sample is used for 'rule in' purposes, but not to 'rule out' myocardial damage;
•Only one threshold (cut-off) value for troponin should be quoted on laboratory reports, values above which are indicative of myocardial damage.
A study by the Wales External Quality Assurance Scheme (WEQAS) enabled the derivation of the recommended cut-off concentrations of troponin for defining myocardial damage, defined for each assay as the concentration that can be reliably distinguished, with a confidence interval of 99%, from the 99th percentile reference limit.
These recommended standards provide a rationale for a uniform approach for troponin assays for patients with chest pain, working towards a standardized approach to the diagnosis and management of patients presenting with acute coronary syndromes. |
---|---|