Loading…
Selective protein removal and desalting using microchip CE
This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip™). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sa...
Saved in:
Published in: | Journal of chromatography. B 2006-07, Vol.839 (1), p.68-73 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593 |
---|---|
cites | cdi_FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593 |
container_end_page | 73 |
container_issue | 1 |
container_start_page | 68 |
container_title | Journal of chromatography. B |
container_volume | 839 |
creator | Silvertand, L.H.H. Machtejevas, E. Hendriks, R. Unger, K.K. van Bennekom, W.P. de Jong, G.J. |
description | This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip™). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100
mM NaCl. However, ITP–CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE–CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel. |
doi_str_mv | 10.1016/j.jchromb.2006.03.036 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68641104</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1570023206002558</els_id><sourcerecordid>68641104</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMo7rr6E5Re9NY6Sdqk9SKyrB-w4EEFbyFNUjelH2vSLvjvzbIFj8Iwk8Mzk5cHoUsMCQbMbuukVhvXt2VCAFgCNBQ7QnOccxpTzj6PwzvjEAOhZIbOvK8BMAdOT9EMMwbAAebo7s00Rg12Z6Kt6wdju8iZtt_JJpKdjrTxshls9xWNft9bq1yvNnYbLVfn6KSSjTcX01ygj8fV-_I5Xr8-vSwf1rFKCRliWuSEKQ0M52VBSaqJyinHhGWEAJOqKAmmmFaUMUIqXWAgEmcVaEkKSLOCLtDN4W4I-D0aP4jWemWaRnamH71gOUsxhjSA2QEMGb13phJbZ1vpfgQGsZcmajFJE3tpAmgoFvaupg_GsjX6b2uyFIDrCZBeyaZyslPW_3G8yNPQAnd_4EzQsbPGCa-s6ZTR1gXJQvf2nyi_AI-Kvg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68641104</pqid></control><display><type>article</type><title>Selective protein removal and desalting using microchip CE</title><source>ScienceDirect Journals</source><creator>Silvertand, L.H.H. ; Machtejevas, E. ; Hendriks, R. ; Unger, K.K. ; van Bennekom, W.P. ; de Jong, G.J.</creator><creatorcontrib>Silvertand, L.H.H. ; Machtejevas, E. ; Hendriks, R. ; Unger, K.K. ; van Bennekom, W.P. ; de Jong, G.J.</creatorcontrib><description>This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip™). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100
mM NaCl. However, ITP–CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE–CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.</description><identifier>ISSN: 1570-0232</identifier><identifier>EISSN: 1873-376X</identifier><identifier>DOI: 10.1016/j.jchromb.2006.03.036</identifier><identifier>PMID: 16600700</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>2D microfluidic device ; Analysis ; Analytical, structural and metabolic biochemistry ; Animals ; Biological and medical sciences ; Electrophoresis, Microchip - instrumentation ; Electrophoresis, Microchip - methods ; Fundamental and applied biological sciences. Psychology ; General pharmacology ; Humans ; Isotachophoresis-zone electrophoresis ; Medical sciences ; On chip sample pretreatment ; Online Systems ; Pharmacology. Drug treatments ; Proteins - chemistry ; Proteins - isolation & purification ; Proteins and peptides ; Sample depletion</subject><ispartof>Journal of chromatography. B, 2006-07, Vol.839 (1), p.68-73</ispartof><rights>2006 Elsevier B.V.</rights><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593</citedby><cites>FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23930,23931,25140,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=17984179$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16600700$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Silvertand, L.H.H.</creatorcontrib><creatorcontrib>Machtejevas, E.</creatorcontrib><creatorcontrib>Hendriks, R.</creatorcontrib><creatorcontrib>Unger, K.K.</creatorcontrib><creatorcontrib>van Bennekom, W.P.</creatorcontrib><creatorcontrib>de Jong, G.J.</creatorcontrib><title>Selective protein removal and desalting using microchip CE</title><title>Journal of chromatography. B</title><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><description>This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip™). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100
mM NaCl. However, ITP–CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE–CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.</description><subject>2D microfluidic device</subject><subject>Analysis</subject><subject>Analytical, structural and metabolic biochemistry</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Electrophoresis, Microchip - instrumentation</subject><subject>Electrophoresis, Microchip - methods</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Isotachophoresis-zone electrophoresis</subject><subject>Medical sciences</subject><subject>On chip sample pretreatment</subject><subject>Online Systems</subject><subject>Pharmacology. Drug treatments</subject><subject>Proteins - chemistry</subject><subject>Proteins - isolation & purification</subject><subject>Proteins and peptides</subject><subject>Sample depletion</subject><issn>1570-0232</issn><issn>1873-376X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LxDAQhoMo7rr6E5Re9NY6Sdqk9SKyrB-w4EEFbyFNUjelH2vSLvjvzbIFj8Iwk8Mzk5cHoUsMCQbMbuukVhvXt2VCAFgCNBQ7QnOccxpTzj6PwzvjEAOhZIbOvK8BMAdOT9EMMwbAAebo7s00Rg12Z6Kt6wdju8iZtt_JJpKdjrTxshls9xWNft9bq1yvNnYbLVfn6KSSjTcX01ygj8fV-_I5Xr8-vSwf1rFKCRliWuSEKQ0M52VBSaqJyinHhGWEAJOqKAmmmFaUMUIqXWAgEmcVaEkKSLOCLtDN4W4I-D0aP4jWemWaRnamH71gOUsxhjSA2QEMGb13phJbZ1vpfgQGsZcmajFJE3tpAmgoFvaupg_GsjX6b2uyFIDrCZBeyaZyslPW_3G8yNPQAnd_4EzQsbPGCa-s6ZTR1gXJQvf2nyi_AI-Kvg</recordid><startdate>20060724</startdate><enddate>20060724</enddate><creator>Silvertand, L.H.H.</creator><creator>Machtejevas, E.</creator><creator>Hendriks, R.</creator><creator>Unger, K.K.</creator><creator>van Bennekom, W.P.</creator><creator>de Jong, G.J.</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060724</creationdate><title>Selective protein removal and desalting using microchip CE</title><author>Silvertand, L.H.H. ; Machtejevas, E. ; Hendriks, R. ; Unger, K.K. ; van Bennekom, W.P. ; de Jong, G.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>2D microfluidic device</topic><topic>Analysis</topic><topic>Analytical, structural and metabolic biochemistry</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Electrophoresis, Microchip - instrumentation</topic><topic>Electrophoresis, Microchip - methods</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Isotachophoresis-zone electrophoresis</topic><topic>Medical sciences</topic><topic>On chip sample pretreatment</topic><topic>Online Systems</topic><topic>Pharmacology. Drug treatments</topic><topic>Proteins - chemistry</topic><topic>Proteins - isolation & purification</topic><topic>Proteins and peptides</topic><topic>Sample depletion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Silvertand, L.H.H.</creatorcontrib><creatorcontrib>Machtejevas, E.</creatorcontrib><creatorcontrib>Hendriks, R.</creatorcontrib><creatorcontrib>Unger, K.K.</creatorcontrib><creatorcontrib>van Bennekom, W.P.</creatorcontrib><creatorcontrib>de Jong, G.J.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatography. B</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Silvertand, L.H.H.</au><au>Machtejevas, E.</au><au>Hendriks, R.</au><au>Unger, K.K.</au><au>van Bennekom, W.P.</au><au>de Jong, G.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Selective protein removal and desalting using microchip CE</atitle><jtitle>Journal of chromatography. B</jtitle><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><date>2006-07-24</date><risdate>2006</risdate><volume>839</volume><issue>1</issue><spage>68</spage><epage>73</epage><pages>68-73</pages><issn>1570-0232</issn><eissn>1873-376X</eissn><abstract>This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip™). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100
mM NaCl. However, ITP–CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE–CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>16600700</pmid><doi>10.1016/j.jchromb.2006.03.036</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1570-0232 |
ispartof | Journal of chromatography. B, 2006-07, Vol.839 (1), p.68-73 |
issn | 1570-0232 1873-376X |
language | eng |
recordid | cdi_proquest_miscellaneous_68641104 |
source | ScienceDirect Journals |
subjects | 2D microfluidic device Analysis Analytical, structural and metabolic biochemistry Animals Biological and medical sciences Electrophoresis, Microchip - instrumentation Electrophoresis, Microchip - methods Fundamental and applied biological sciences. Psychology General pharmacology Humans Isotachophoresis-zone electrophoresis Medical sciences On chip sample pretreatment Online Systems Pharmacology. Drug treatments Proteins - chemistry Proteins - isolation & purification Proteins and peptides Sample depletion |
title | Selective protein removal and desalting using microchip CE |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T03%3A08%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Selective%20protein%20removal%20and%20desalting%20using%20microchip%20CE&rft.jtitle=Journal%20of%20chromatography.%20B&rft.au=Silvertand,%20L.H.H.&rft.date=2006-07-24&rft.volume=839&rft.issue=1&rft.spage=68&rft.epage=73&rft.pages=68-73&rft.issn=1570-0232&rft.eissn=1873-376X&rft_id=info:doi/10.1016/j.jchromb.2006.03.036&rft_dat=%3Cproquest_cross%3E68641104%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c422t-39826cd0618b9324d2c83712652206ac9b21313f36622fd9102a15f0da2904593%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68641104&rft_id=info:pmid/16600700&rfr_iscdi=true |