Strut Failure in the Body of the Zenith Abdominal Endoprosthesis

Endovascular repair of abdominal aortic aneurysm is a technology that has undergone rapid technological evolution with a number of different types of grafts developed and concern has been the structural integrity of the metallic endoskeleton. We describe our experiences of strut failure in the Zenit...

Full description

Saved in:
Bibliographic Details
Published in:European journal of vascular and endovascular surgery 2006-08, Vol.32 (2), p.136-139
Main Authors: Rumball-Smith, A., Wright, I.A., Buckenham, T.M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203
cites cdi_FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203
container_end_page 139
container_issue 2
container_start_page 136
container_title European journal of vascular and endovascular surgery
container_volume 32
creator Rumball-Smith, A.
Wright, I.A.
Buckenham, T.M.
description Endovascular repair of abdominal aortic aneurysm is a technology that has undergone rapid technological evolution with a number of different types of grafts developed and concern has been the structural integrity of the metallic endoskeleton. We describe our experiences of strut failure in the Zenith abdominal aneurysm endograft device. Eighty-four patients have undergone endovascular repair of their abdominal aortic aneurysm at Christchurch Hospital from 1996 to 2005, all with the Zenith endoprosthesis. All available plain radiographs of the endoprosthesis (AP and lateral planes) were reviewed retrospectively, by a single experience observer, to assess strut failure. Three cases of strut failure in second-generation grafts were identified, each in the inferior body of the graft above the iliac bifurcation. There was no clear evidence that these strut failures were associated with clinical complications. This is the first time that strut failure in the Zenith abdominal endoprosthesis has been reported. Whilst in each of our three cases this does not appear to have been of clinical significance, these findings re-iterate the necessity of life-long surveillance of this technology.
doi_str_mv 10.1016/j.ejvs.2006.01.018
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68691307</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1078588406000918</els_id><sourcerecordid>68691307</sourcerecordid><originalsourceid>FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203</originalsourceid><addsrcrecordid>eNp9UE1PwzAMjRCIjcEf4IB64taSjzZNJQ7AtAHSJA7AhUuUJq6Wqh8jaSft35OxSdyQLNuyn5_th9A1wQnBhN_VCdRbn1CMeYJJMHGCpiRjNKaEZ6chx7mIMyHSCbrwvsYYZ4Rl52gS2jwlQkzRw_vgxiFaKtuMDiLbRcMaoqfe7KK--s2_oLPDOnosTd_aTjXRojP9xvU-NL31l-isUo2Hq2Ococ_l4mP-Eq_enl_nj6tYs0IMwVclpbnBVFRQMJqqjGQUpwVlPOUVzTEIgMIUZVEqXoayUUYIRqhOdUkxm6HbA29Y_T2CH2RrvYamUR30o5dc8IIwnAcgPQB1uNE7qOTG2Va5nSRY7nWTtdzrJve6SUyCiTB0c2QfyxbM38hRqAC4PwAg_Li14KTXFjoNxjrQgzS9_Y__B0NYfao</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68691307</pqid></control><display><type>article</type><title>Strut Failure in the Body of the Zenith Abdominal Endoprosthesis</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Rumball-Smith, A. ; Wright, I.A. ; Buckenham, T.M.</creator><creatorcontrib>Rumball-Smith, A. ; Wright, I.A. ; Buckenham, T.M.</creatorcontrib><description>Endovascular repair of abdominal aortic aneurysm is a technology that has undergone rapid technological evolution with a number of different types of grafts developed and concern has been the structural integrity of the metallic endoskeleton. We describe our experiences of strut failure in the Zenith abdominal aneurysm endograft device. Eighty-four patients have undergone endovascular repair of their abdominal aortic aneurysm at Christchurch Hospital from 1996 to 2005, all with the Zenith endoprosthesis. All available plain radiographs of the endoprosthesis (AP and lateral planes) were reviewed retrospectively, by a single experience observer, to assess strut failure. Three cases of strut failure in second-generation grafts were identified, each in the inferior body of the graft above the iliac bifurcation. There was no clear evidence that these strut failures were associated with clinical complications. This is the first time that strut failure in the Zenith abdominal endoprosthesis has been reported. Whilst in each of our three cases this does not appear to have been of clinical significance, these findings re-iterate the necessity of life-long surveillance of this technology.</description><identifier>ISSN: 1078-5884</identifier><identifier>EISSN: 1532-2165</identifier><identifier>DOI: 10.1016/j.ejvs.2006.01.018</identifier><identifier>PMID: 16564188</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Aged ; Aged, 80 and over ; Aortic aneurysm ; Aortic Aneurysm, Abdominal - surgery ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation ; Endovascular ; Female ; Follow-up ; Humans ; Male ; Middle Aged ; Prosthesis Design ; Prosthesis Failure ; Retrospective Studies ; Stent-graft ; Stents ; Strut failure ; Zenith</subject><ispartof>European journal of vascular and endovascular surgery, 2006-08, Vol.32 (2), p.136-139</ispartof><rights>2006 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203</citedby><cites>FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16564188$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rumball-Smith, A.</creatorcontrib><creatorcontrib>Wright, I.A.</creatorcontrib><creatorcontrib>Buckenham, T.M.</creatorcontrib><title>Strut Failure in the Body of the Zenith Abdominal Endoprosthesis</title><title>European journal of vascular and endovascular surgery</title><addtitle>Eur J Vasc Endovasc Surg</addtitle><description>Endovascular repair of abdominal aortic aneurysm is a technology that has undergone rapid technological evolution with a number of different types of grafts developed and concern has been the structural integrity of the metallic endoskeleton. We describe our experiences of strut failure in the Zenith abdominal aneurysm endograft device. Eighty-four patients have undergone endovascular repair of their abdominal aortic aneurysm at Christchurch Hospital from 1996 to 2005, all with the Zenith endoprosthesis. All available plain radiographs of the endoprosthesis (AP and lateral planes) were reviewed retrospectively, by a single experience observer, to assess strut failure. Three cases of strut failure in second-generation grafts were identified, each in the inferior body of the graft above the iliac bifurcation. There was no clear evidence that these strut failures were associated with clinical complications. This is the first time that strut failure in the Zenith abdominal endoprosthesis has been reported. Whilst in each of our three cases this does not appear to have been of clinical significance, these findings re-iterate the necessity of life-long surveillance of this technology.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Aortic aneurysm</subject><subject>Aortic Aneurysm, Abdominal - surgery</subject><subject>Blood Vessel Prosthesis</subject><subject>Blood Vessel Prosthesis Implantation</subject><subject>Endovascular</subject><subject>Female</subject><subject>Follow-up</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Retrospective Studies</subject><subject>Stent-graft</subject><subject>Stents</subject><subject>Strut failure</subject><subject>Zenith</subject><issn>1078-5884</issn><issn>1532-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9UE1PwzAMjRCIjcEf4IB64taSjzZNJQ7AtAHSJA7AhUuUJq6Wqh8jaSft35OxSdyQLNuyn5_th9A1wQnBhN_VCdRbn1CMeYJJMHGCpiRjNKaEZ6chx7mIMyHSCbrwvsYYZ4Rl52gS2jwlQkzRw_vgxiFaKtuMDiLbRcMaoqfe7KK--s2_oLPDOnosTd_aTjXRojP9xvU-NL31l-isUo2Hq2Ococ_l4mP-Eq_enl_nj6tYs0IMwVclpbnBVFRQMJqqjGQUpwVlPOUVzTEIgMIUZVEqXoayUUYIRqhOdUkxm6HbA29Y_T2CH2RrvYamUR30o5dc8IIwnAcgPQB1uNE7qOTG2Va5nSRY7nWTtdzrJve6SUyCiTB0c2QfyxbM38hRqAC4PwAg_Li14KTXFjoNxjrQgzS9_Y__B0NYfao</recordid><startdate>20060801</startdate><enddate>20060801</enddate><creator>Rumball-Smith, A.</creator><creator>Wright, I.A.</creator><creator>Buckenham, T.M.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060801</creationdate><title>Strut Failure in the Body of the Zenith Abdominal Endoprosthesis</title><author>Rumball-Smith, A. ; Wright, I.A. ; Buckenham, T.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Aortic aneurysm</topic><topic>Aortic Aneurysm, Abdominal - surgery</topic><topic>Blood Vessel Prosthesis</topic><topic>Blood Vessel Prosthesis Implantation</topic><topic>Endovascular</topic><topic>Female</topic><topic>Follow-up</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Retrospective Studies</topic><topic>Stent-graft</topic><topic>Stents</topic><topic>Strut failure</topic><topic>Zenith</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rumball-Smith, A.</creatorcontrib><creatorcontrib>Wright, I.A.</creatorcontrib><creatorcontrib>Buckenham, T.M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of vascular and endovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rumball-Smith, A.</au><au>Wright, I.A.</au><au>Buckenham, T.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Strut Failure in the Body of the Zenith Abdominal Endoprosthesis</atitle><jtitle>European journal of vascular and endovascular surgery</jtitle><addtitle>Eur J Vasc Endovasc Surg</addtitle><date>2006-08-01</date><risdate>2006</risdate><volume>32</volume><issue>2</issue><spage>136</spage><epage>139</epage><pages>136-139</pages><issn>1078-5884</issn><eissn>1532-2165</eissn><abstract>Endovascular repair of abdominal aortic aneurysm is a technology that has undergone rapid technological evolution with a number of different types of grafts developed and concern has been the structural integrity of the metallic endoskeleton. We describe our experiences of strut failure in the Zenith abdominal aneurysm endograft device. Eighty-four patients have undergone endovascular repair of their abdominal aortic aneurysm at Christchurch Hospital from 1996 to 2005, all with the Zenith endoprosthesis. All available plain radiographs of the endoprosthesis (AP and lateral planes) were reviewed retrospectively, by a single experience observer, to assess strut failure. Three cases of strut failure in second-generation grafts were identified, each in the inferior body of the graft above the iliac bifurcation. There was no clear evidence that these strut failures were associated with clinical complications. This is the first time that strut failure in the Zenith abdominal endoprosthesis has been reported. Whilst in each of our three cases this does not appear to have been of clinical significance, these findings re-iterate the necessity of life-long surveillance of this technology.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>16564188</pmid><doi>10.1016/j.ejvs.2006.01.018</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1078-5884
ispartof European journal of vascular and endovascular surgery, 2006-08, Vol.32 (2), p.136-139
issn 1078-5884
1532-2165
language eng
recordid cdi_proquest_miscellaneous_68691307
source ScienceDirect Freedom Collection 2022-2024
subjects Aged
Aged, 80 and over
Aortic aneurysm
Aortic Aneurysm, Abdominal - surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation
Endovascular
Female
Follow-up
Humans
Male
Middle Aged
Prosthesis Design
Prosthesis Failure
Retrospective Studies
Stent-graft
Stents
Strut failure
Zenith
title Strut Failure in the Body of the Zenith Abdominal Endoprosthesis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T02%3A16%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Strut%20Failure%20in%20the%20Body%20of%20the%20Zenith%20Abdominal%20Endoprosthesis&rft.jtitle=European%20journal%20of%20vascular%20and%20endovascular%20surgery&rft.au=Rumball-Smith,%20A.&rft.date=2006-08-01&rft.volume=32&rft.issue=2&rft.spage=136&rft.epage=139&rft.pages=136-139&rft.issn=1078-5884&rft.eissn=1532-2165&rft_id=info:doi/10.1016/j.ejvs.2006.01.018&rft_dat=%3Cproquest_cross%3E68691307%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c398t-c3fb227d028fe9324a515204923646f270e8ee9d9b9ba6b923dad88312c4cb203%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68691307&rft_id=info:pmid/16564188&rfr_iscdi=true