Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends

The aim was to assess which factors cause a systematic error in serum total cholesterol measurements and how bias can influence the interpretation of serum cholesterol changes of the Finnish population. Data on precision and accuracy during 27 years for serum total cholesterol were documented from p...

Full description

Saved in:
Bibliographic Details
Published in:Clinica chimica acta 2007-03, Vol.378 (1), p.93-98
Main Authors: Sundvall, Jouko, Leiviskä, Jaana, Alfthan, Georg, Vartiainen, Erkki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123
cites cdi_FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123
container_end_page 98
container_issue 1
container_start_page 93
container_title Clinica chimica acta
container_volume 378
creator Sundvall, Jouko
Leiviskä, Jaana
Alfthan, Georg
Vartiainen, Erkki
description The aim was to assess which factors cause a systematic error in serum total cholesterol measurements and how bias can influence the interpretation of serum cholesterol changes of the Finnish population. Data on precision and accuracy during 27 years for serum total cholesterol were documented from participation in 438 rounds of five different external quality assessment (EQA) programs. The mean annual accuracy (bias) of the cholesterol assay using the results from all EQAs during 1978–2004 was − 0.74% (95%CI − 0.88 to − 0.60). An exceptionally large deviation in bias coincided with the introduction of a new serum calibrator lot. New methods or instrumentation had only a minor impact on serum cholesterol bias. The mean serum cholesterol bias during the latest five population studies in 1982–2002 was −0.10% (95%CI −0.60 to 0.40) but comparison of the bias between the last study (CDC EQA in 2002) and the four previous ones (WHO EQA) showed a net difference of 3.32% ( p < 0.001). Correcting the mean serum cholesterol of men with respect to WHO and CDC EQA bias changed the interpretation for the last two survey years from an increase of 1.8% to no change. It is necessary to participate in EQA programs, which include target values measured by the CDC cholesterol reference method and then to perform bias corrections on the mean cholesterol values of the populations.
doi_str_mv 10.1016/j.cca.2006.10.021
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_69022686</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0009898106007108</els_id><sourcerecordid>69022686</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123</originalsourceid><addsrcrecordid>eNp9kMFu1DAQhi0EotvCA3BBPnHL4nESJ4ZTVQFFqsSBcrYce0K9SuIwTirtI_QteBaerN7uStwqWbJm9M0_mo-xdyC2IEB93G2ds1sphMr1Vkh4wTbQNmVRVlq-ZBshhC5a3cIZO09pl8tKKHjNzqABpctabtjDT6R15O4uDpgWpDhwv1KYfnPZ_Pu7R0vpE79MCVMacVp47HnaZ3C0S3AciSJxO3lu-x7dcpjrrVsipafucoeBeA5FHqb88oKZ8Amb47wOOSROfCGcfHrDXvV2SPj29F-wX1-_3F5dFzc_vn2_urwpXFnDUrQWq6aD1iPWtcaqF1Xf5e3QVaBU49sKhaxBVVr1ErQXdYkdaOVbab0GWV6wD8fcmeKfNR9txpAcDoOdMK7JKC2kVK3KIBxBRzElwt7MFEZLewPCHPybncn-zcH_oZX955n3p_C1G9H_nzgJz8DnI4D5xPuAZJILODn0gbJA42N4Jv4RJSiZRw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69022686</pqid></control><display><type>article</type><title>Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends</title><source>Elsevier</source><creator>Sundvall, Jouko ; Leiviskä, Jaana ; Alfthan, Georg ; Vartiainen, Erkki</creator><creatorcontrib>Sundvall, Jouko ; Leiviskä, Jaana ; Alfthan, Georg ; Vartiainen, Erkki</creatorcontrib><description>The aim was to assess which factors cause a systematic error in serum total cholesterol measurements and how bias can influence the interpretation of serum cholesterol changes of the Finnish population. Data on precision and accuracy during 27 years for serum total cholesterol were documented from participation in 438 rounds of five different external quality assessment (EQA) programs. The mean annual accuracy (bias) of the cholesterol assay using the results from all EQAs during 1978–2004 was − 0.74% (95%CI − 0.88 to − 0.60). An exceptionally large deviation in bias coincided with the introduction of a new serum calibrator lot. New methods or instrumentation had only a minor impact on serum cholesterol bias. The mean serum cholesterol bias during the latest five population studies in 1982–2002 was −0.10% (95%CI −0.60 to 0.40) but comparison of the bias between the last study (CDC EQA in 2002) and the four previous ones (WHO EQA) showed a net difference of 3.32% ( p &lt; 0.001). Correcting the mean serum cholesterol of men with respect to WHO and CDC EQA bias changed the interpretation for the last two survey years from an increase of 1.8% to no change. It is necessary to participate in EQA programs, which include target values measured by the CDC cholesterol reference method and then to perform bias corrections on the mean cholesterol values of the populations.</description><identifier>ISSN: 0009-8981</identifier><identifier>EISSN: 1873-3492</identifier><identifier>DOI: 10.1016/j.cca.2006.10.021</identifier><identifier>PMID: 17169352</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Bias ; Bias external quality assessment ; Calibration ; Centers for Disease Control and Prevention (U.S.) ; Cholesterol - blood ; Humans ; Population health survey ; Serum cholesterol ; Systematic error ; Time Factors ; United States ; World Health Organization</subject><ispartof>Clinica chimica acta, 2007-03, Vol.378 (1), p.93-98</ispartof><rights>2006 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123</citedby><cites>FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17169352$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sundvall, Jouko</creatorcontrib><creatorcontrib>Leiviskä, Jaana</creatorcontrib><creatorcontrib>Alfthan, Georg</creatorcontrib><creatorcontrib>Vartiainen, Erkki</creatorcontrib><title>Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends</title><title>Clinica chimica acta</title><addtitle>Clin Chim Acta</addtitle><description>The aim was to assess which factors cause a systematic error in serum total cholesterol measurements and how bias can influence the interpretation of serum cholesterol changes of the Finnish population. Data on precision and accuracy during 27 years for serum total cholesterol were documented from participation in 438 rounds of five different external quality assessment (EQA) programs. The mean annual accuracy (bias) of the cholesterol assay using the results from all EQAs during 1978–2004 was − 0.74% (95%CI − 0.88 to − 0.60). An exceptionally large deviation in bias coincided with the introduction of a new serum calibrator lot. New methods or instrumentation had only a minor impact on serum cholesterol bias. The mean serum cholesterol bias during the latest five population studies in 1982–2002 was −0.10% (95%CI −0.60 to 0.40) but comparison of the bias between the last study (CDC EQA in 2002) and the four previous ones (WHO EQA) showed a net difference of 3.32% ( p &lt; 0.001). Correcting the mean serum cholesterol of men with respect to WHO and CDC EQA bias changed the interpretation for the last two survey years from an increase of 1.8% to no change. It is necessary to participate in EQA programs, which include target values measured by the CDC cholesterol reference method and then to perform bias corrections on the mean cholesterol values of the populations.</description><subject>Bias</subject><subject>Bias external quality assessment</subject><subject>Calibration</subject><subject>Centers for Disease Control and Prevention (U.S.)</subject><subject>Cholesterol - blood</subject><subject>Humans</subject><subject>Population health survey</subject><subject>Serum cholesterol</subject><subject>Systematic error</subject><subject>Time Factors</subject><subject>United States</subject><subject>World Health Organization</subject><issn>0009-8981</issn><issn>1873-3492</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kMFu1DAQhi0EotvCA3BBPnHL4nESJ4ZTVQFFqsSBcrYce0K9SuIwTirtI_QteBaerN7uStwqWbJm9M0_mo-xdyC2IEB93G2ds1sphMr1Vkh4wTbQNmVRVlq-ZBshhC5a3cIZO09pl8tKKHjNzqABpctabtjDT6R15O4uDpgWpDhwv1KYfnPZ_Pu7R0vpE79MCVMacVp47HnaZ3C0S3AciSJxO3lu-x7dcpjrrVsipafucoeBeA5FHqb88oKZ8Amb47wOOSROfCGcfHrDXvV2SPj29F-wX1-_3F5dFzc_vn2_urwpXFnDUrQWq6aD1iPWtcaqF1Xf5e3QVaBU49sKhaxBVVr1ErQXdYkdaOVbab0GWV6wD8fcmeKfNR9txpAcDoOdMK7JKC2kVK3KIBxBRzElwt7MFEZLewPCHPybncn-zcH_oZX955n3p_C1G9H_nzgJz8DnI4D5xPuAZJILODn0gbJA42N4Jv4RJSiZRw</recordid><startdate>20070301</startdate><enddate>20070301</enddate><creator>Sundvall, Jouko</creator><creator>Leiviskä, Jaana</creator><creator>Alfthan, Georg</creator><creator>Vartiainen, Erkki</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070301</creationdate><title>Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends</title><author>Sundvall, Jouko ; Leiviskä, Jaana ; Alfthan, Georg ; Vartiainen, Erkki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Bias</topic><topic>Bias external quality assessment</topic><topic>Calibration</topic><topic>Centers for Disease Control and Prevention (U.S.)</topic><topic>Cholesterol - blood</topic><topic>Humans</topic><topic>Population health survey</topic><topic>Serum cholesterol</topic><topic>Systematic error</topic><topic>Time Factors</topic><topic>United States</topic><topic>World Health Organization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sundvall, Jouko</creatorcontrib><creatorcontrib>Leiviskä, Jaana</creatorcontrib><creatorcontrib>Alfthan, Georg</creatorcontrib><creatorcontrib>Vartiainen, Erkki</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sundvall, Jouko</au><au>Leiviskä, Jaana</au><au>Alfthan, Georg</au><au>Vartiainen, Erkki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends</atitle><jtitle>Clinica chimica acta</jtitle><addtitle>Clin Chim Acta</addtitle><date>2007-03-01</date><risdate>2007</risdate><volume>378</volume><issue>1</issue><spage>93</spage><epage>98</epage><pages>93-98</pages><issn>0009-8981</issn><eissn>1873-3492</eissn><abstract>The aim was to assess which factors cause a systematic error in serum total cholesterol measurements and how bias can influence the interpretation of serum cholesterol changes of the Finnish population. Data on precision and accuracy during 27 years for serum total cholesterol were documented from participation in 438 rounds of five different external quality assessment (EQA) programs. The mean annual accuracy (bias) of the cholesterol assay using the results from all EQAs during 1978–2004 was − 0.74% (95%CI − 0.88 to − 0.60). An exceptionally large deviation in bias coincided with the introduction of a new serum calibrator lot. New methods or instrumentation had only a minor impact on serum cholesterol bias. The mean serum cholesterol bias during the latest five population studies in 1982–2002 was −0.10% (95%CI −0.60 to 0.40) but comparison of the bias between the last study (CDC EQA in 2002) and the four previous ones (WHO EQA) showed a net difference of 3.32% ( p &lt; 0.001). Correcting the mean serum cholesterol of men with respect to WHO and CDC EQA bias changed the interpretation for the last two survey years from an increase of 1.8% to no change. It is necessary to participate in EQA programs, which include target values measured by the CDC cholesterol reference method and then to perform bias corrections on the mean cholesterol values of the populations.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>17169352</pmid><doi>10.1016/j.cca.2006.10.021</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-8981
ispartof Clinica chimica acta, 2007-03, Vol.378 (1), p.93-98
issn 0009-8981
1873-3492
language eng
recordid cdi_proquest_miscellaneous_69022686
source Elsevier
subjects Bias
Bias external quality assessment
Calibration
Centers for Disease Control and Prevention (U.S.)
Cholesterol - blood
Humans
Population health survey
Serum cholesterol
Systematic error
Time Factors
United States
World Health Organization
title Serum cholesterol during 27 years: Assessment of systematic error and affecting factors and their role in interpreting population trends
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T12%3A45%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Serum%20cholesterol%20during%2027%C2%A0years:%20Assessment%20of%20systematic%20error%20and%20affecting%20factors%20and%20their%20role%20in%20interpreting%20population%20trends&rft.jtitle=Clinica%20chimica%20acta&rft.au=Sundvall,%20Jouko&rft.date=2007-03-01&rft.volume=378&rft.issue=1&rft.spage=93&rft.epage=98&rft.pages=93-98&rft.issn=0009-8981&rft.eissn=1873-3492&rft_id=info:doi/10.1016/j.cca.2006.10.021&rft_dat=%3Cproquest_cross%3E69022686%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c351t-8ae47b18dee559e4f04fbaff1b41667d84e02516496f219d053eb196d82ad9123%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=69022686&rft_id=info:pmid/17169352&rfr_iscdi=true